  "id": 5444,
  "url": "https://nnemf.org/research/5444-exposure-of-baboons-to-combined-60-hz-electric",
  "title": "Exposure of baboons to combined 60 Hz electric and magnetic fields does not produce work stoppage or affect operant performance on a match-to-sample task.",
  "authors": [
    "J L Orr",
    "W R Rogers",
    "H D Smith"
  ],
  "journal": "Bioelectromagnetics",
  "year": "1995",
  "doi": "10.1002/bem.2250160707",
  "pmid": "8787567",
  "abstract": "We examined the effects of combined 60 Hz electric and magnetic field (EMF) exposure on performance of delayed match-to-sample (MTS) procedure involving the flash rate of a light as the stimulus. Six baboons (Papio cynocephalus) fully acquired the task; four others functioned accurately only when cued. All ten subjects were assigned to EMF-exposed or sham-exposed groups of five and were used to test for a work-stoppage effect that was previously observed with initial exposure to electric fields (EF) of 30 or 60 kV/m. Here, we report the results of two experiments, each consisting of 6 week preexposure, exposure, and postexposure periods. We found no evidence of work stoppage with fields of 6 kV/m and 50 microT (0.5 G) or with 30 kV/m and 100 microT (1.0 G). In neither experiment was there evidence of an adverse effect of 60 Hz EMF exposure on MTS performance.",
  "effect": "no_effect",
  "evidence": "low",
  "extraction": {
    "studyType": "animal",
    "studyTypeLabel": "Animal study",
    "effectDirection": "no_effect",
    "evidenceLabel": "Low",
    "population": "Baboons (Papio cynocephalus)",
    "sampleSize": "10",
    "exposure": "ELF · 0.06 MHz · Two experiments; each had 6-week preexposure, exposure, and postexposure periods (exposure duration not further specified).",
    "confidencePct": "78",
    "peerReviewed": "yes",
    "mainFindings": "Across two experiments, there was no evidence of work stoppage at 6 kV/m with 50 microT (0.5 G) or at 30 kV/m with 100 microT (1.0 G). No adverse effects of 60 Hz combined electric and magnetic field exposure were observed on MTS task performance.",
    "outcomes": [
      "Work stoppage",
      "Operant performance on delayed match-to-sample (MTS) task (flash rate of a light as stimulus)"
    ],
    "limitations": [
      "Small sample size (10 baboons",
      "5 exposed and 5 sham per experiment/grouping as described)",
      "Exposure duration within the exposure period not specified in the abstract",
      "Some animals required cueing to perform accurately",
      "which may affect generalizability of performance outcomes"
    ],
    "keywords": [
      "60 Hz",
      "ELF",
      "electric field",
      "magnetic field",
      "baboons",
      "Papio cynocephalus",
      "work stoppage",
      "operant performance",
      "delayed match-to-sample"
    ],
    "hubs": [
      {
        "slug": "occupational-exposure",
        "weight": "0.7",
        "reason": "Study examines combined 60 Hz electric and magnetic fields at kV/m and microtesla levels relevant to power-frequency environments, though no specific workplace setting is stated."
      }
    ],
    "raw": "{\n  \"study_type\": \"animal\",\n  \"exposure\": {\n    \"band\": \"ELF\",\n    \"source\": null,\n    \"frequency_mhz\": 0.06,\n    \"sar_wkg\": null,\n    \"duration\": \"Two experiments; each had 6-week preexposure, exposure, and postexposure periods (exposure duration not further specified).\"\n  },\n  \"population\": \"Baboons (Papio cynocephalus)\",\n  \"sample_size\": 10,\n  \"outcomes\": [\n    \"Work stoppage\",\n    \"Operant performance on delayed match-to-sample (MTS) task (flash rate of a light as stimulus)\"\n  ],\n  \"main_findings\": \"Across two experiments, there was no evidence of work stoppage at 6 kV/m with 50 microT (0.5 G) or at 30 kV/m with 100 microT (1.0 G). No adverse effects of 60 Hz combined electric and magnetic field exposure were observed on MTS task performance.\",\n  \"effect_direction\": \"no_effect\",\n  \"limitations\": [\n    \"Small sample size (10 baboons; 5 exposed and 5 sham per experiment/grouping as described)\",\n    \"Exposure duration within the exposure period not specified in the abstract\",\n    \"Some animals required cueing to perform accurately, which may affect generalizability of performance outcomes\"\n  ],\n  \"evidence_strength\": \"low\",\n  \"confidence\": 0.78,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"60 Hz\",\n    \"ELF\",\n    \"electric field\",\n    \"magnetic field\",\n    \"baboons\",\n    \"Papio cynocephalus\",\n    \"work stoppage\",\n    \"operant performance\",\n    \"delayed match-to-sample\"\n  ],\n  \"suggested_hubs\": [\n    {\n      \"slug\": \"occupational-exposure\",\n      \"weight\": 0.25,\n      \"reason\": \"Study examines combined 60 Hz electric and magnetic fields at kV/m and microtesla levels relevant to power-frequency environments, though no specific workplace setting is stated.\"\n    }\n  ]\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/8787567/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=5444",
  "updated": "2026-02-14 08:24:57"
}