  "id": 5446,
  "url": "https://nnemf.org/research/5446-rapid-onset-offset-variably-scheduled-60-hz-electric",
  "title": "Rapid-onset/offset, variably scheduled 60 Hz electric and magnetic field exposure reduces nocturnal serum melatonin concentration in nonhuman primates.",
  "authors": [
    "W R Rogers",
    "R J Reiter",
    "H D Smith",
    "L Barlow-Walden"
  ],
  "journal": "Bioelectromagnetics",
  "year": "1995",
  "doi": "10.1002/bem.2250160712",
  "pmid": "8787562",
  "abstract": "Experiments with rodents indicate that power-frequency electric field (EF) or magnetic field (MF) exposure can suppress the normal nocturnal increase in melatonin concentration in pineal gland and blood. In a separate set of three experiments conducted with nonhuman primates, we did not observe melatonin suppression as a result of 6 weeks of day-time exposure to combined 60 Hz electric and magnetic fields (E/MF) with regularly scheduled \"slow\" E/MF onsets/offsets. The study described here used a different exposure paradigm in which two baboons were exposed to E/MF with \"rapid\" E/MF onsets/offsets accompanied by EF transients not found with slowly ramped E/MF onset/offset; profound reductions in nocturnal serum melatonin concentration were observed in this experiment. If replicated in a more extensive experiment, the observation of melatonin suppression only in the presence of E/MF transients would suggest that very specific exposure parameters determine the effects of 60 Hz E/MF on melatonin.",
  "effect": "mixed",
  "evidence": "very_low",
  "extraction": {
    "studyType": "animal",
    "studyTypeLabel": "Animal study",
    "effectDirection": "mixed",
    "evidenceLabel": "Very low",
    "population": "Two baboons (nonhuman primates)",
    "sampleSize": "2",
    "exposure": "ELF · 0.06 MHz",
    "confidencePct": "74",
    "peerReviewed": "yes",
    "mainFindings": "In two baboons exposed to combined 60 Hz electric and magnetic fields with rapid onsets/offsets (with associated electric-field transients), profound reductions in nocturnal serum melatonin concentration were observed. The abstract contrasts this with prior primate experiments in which 6 weeks of daytime exposure with regularly scheduled slow onsets/offsets did not show melatonin suppression.",
    "outcomes": [
      "Nocturnal serum melatonin concentration"
    ],
    "limitations": [
      "Very small sample size (two baboons)",
      "Findings described as needing replication in a more extensive experiment",
      "Exposure duration and detailed exposure metrics (field strengths) not provided in the abstract"
    ],
    "keywords": [
      "60 Hz",
      "ELF",
      "electric field",
      "magnetic field",
      "transients",
      "rapid onset/offset",
      "melatonin",
      "nocturnal",
      "serum",
      "baboons",
      "nonhuman primates"
    ],
    "hubs": [
      {
        "slug": "occupational-exposure",
        "weight": "0.7",
        "reason": "Study concerns power-frequency (60 Hz) electric and magnetic field exposure, which is commonly discussed in occupational/utility contexts, though the abstract does not specify an occupational setting."
      }
    ],
    "raw": "{\n  \"study_type\": \"animal\",\n  \"exposure\": {\n    \"band\": \"ELF\",\n    \"source\": null,\n    \"frequency_mhz\": 0.06,\n    \"sar_wkg\": null,\n    \"duration\": null\n  },\n  \"population\": \"Two baboons (nonhuman primates)\",\n  \"sample_size\": 2,\n  \"outcomes\": [\n    \"Nocturnal serum melatonin concentration\"\n  ],\n  \"main_findings\": \"In two baboons exposed to combined 60 Hz electric and magnetic fields with rapid onsets/offsets (with associated electric-field transients), profound reductions in nocturnal serum melatonin concentration were observed. The abstract contrasts this with prior primate experiments in which 6 weeks of daytime exposure with regularly scheduled slow onsets/offsets did not show melatonin suppression.\",\n  \"effect_direction\": \"mixed\",\n  \"limitations\": [\n    \"Very small sample size (two baboons)\",\n    \"Findings described as needing replication in a more extensive experiment\",\n    \"Exposure duration and detailed exposure metrics (field strengths) not provided in the abstract\"\n  ],\n  \"evidence_strength\": \"very_low\",\n  \"confidence\": 0.74,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"60 Hz\",\n    \"ELF\",\n    \"electric field\",\n    \"magnetic field\",\n    \"transients\",\n    \"rapid onset/offset\",\n    \"melatonin\",\n    \"nocturnal\",\n    \"serum\",\n    \"baboons\",\n    \"nonhuman primates\"\n  ],\n  \"suggested_hubs\": [\n    {\n      \"slug\": \"occupational-exposure\",\n      \"weight\": 0.2,\n      \"reason\": \"Study concerns power-frequency (60 Hz) electric and magnetic field exposure, which is commonly discussed in occupational/utility contexts, though the abstract does not specify an occupational setting.\"\n    }\n  ]\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/8787562/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=5446",
  "updated": "2026-02-14 08:24:58"
}