  "id": 5456,
  "url": "https://nnemf.org/research/5456-frequency-specific-blocking-in-the-human-brain-caused",
  "title": "Frequency-specific blocking in the human brain caused by electromagnetic fields.",
  "authors": [
    "G B Bell",
    "A A Marino",
    "A L Chesson"
  ],
  "journal": "Neuroreport",
  "year": "1994",
  "doi": "10.1097/00001756-199401120-00036",
  "pmid": "8003686",
  "abstract": "Based on preliminary observations that continuous exposure to electromagnetic fields (EMFs) produced an after-effect on human brain electrical activity, the effect of 10 Hz, 1 gauss, on the intrinsic activity of the brain at that frequency was studied. Ten subjects were exposed for 10 min and the 10 Hz spectral power was measured during the 1 min interval following stimulation and compared with control values obtained from the same subjects. Significantly reduced brain electrical activity from the occipital electrodes following termination of the EMF exposure was observed, thereby confirming the preliminary results.",
  "effect": "mixed",
  "evidence": "very_low",
  "extraction": {
    "studyType": "unknown",
    "studyTypeLabel": "Unknown",
    "effectDirection": "mixed",
    "evidenceLabel": "Very low",
    "population": "Human subjects",
    "sampleSize": "10",
    "exposure": "ELF · 10 min",
    "confidencePct": "66",
    "peerReviewed": "yes",
    "mainFindings": "Ten subjects exposed to a 10 Hz, 1 gauss electromagnetic field for 10 minutes showed significantly reduced 10 Hz brain electrical activity at occipital electrodes during the 1-minute interval after exposure compared with control values from the same subjects.",
    "outcomes": [
      "Brain electrical activity (EEG)",
      "10 Hz spectral power",
      "Occipital electrode activity"
    ],
    "limitations": [
      "Small sample size (n=10)",
      "Only short-term after-effect assessed (1 minute post-exposure)",
      "Exposure source and other exposure parameters not described in the abstract"
    ],
    "keywords": [
      "electromagnetic fields",
      "ELF",
      "10 Hz",
      "1 gauss",
      "EEG",
      "spectral power",
      "occipital electrodes",
      "after-effect"
    ],
    "hubs": [],
    "raw": "{\n  \"study_type\": \"unknown\",\n  \"exposure\": {\n    \"band\": \"ELF\",\n    \"source\": null,\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": \"10 min\"\n  },\n  \"population\": \"Human subjects\",\n  \"sample_size\": 10,\n  \"outcomes\": [\n    \"Brain electrical activity (EEG)\",\n    \"10 Hz spectral power\",\n    \"Occipital electrode activity\"\n  ],\n  \"main_findings\": \"Ten subjects exposed to a 10 Hz, 1 gauss electromagnetic field for 10 minutes showed significantly reduced 10 Hz brain electrical activity at occipital electrodes during the 1-minute interval after exposure compared with control values from the same subjects.\",\n  \"effect_direction\": \"mixed\",\n  \"limitations\": [\n    \"Small sample size (n=10)\",\n    \"Only short-term after-effect assessed (1 minute post-exposure)\",\n    \"Exposure source and other exposure parameters not described in the abstract\"\n  ],\n  \"evidence_strength\": \"very_low\",\n  \"confidence\": 0.66,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"electromagnetic fields\",\n    \"ELF\",\n    \"10 Hz\",\n    \"1 gauss\",\n    \"EEG\",\n    \"spectral power\",\n    \"occipital electrodes\",\n    \"after-effect\"\n  ],\n  \"suggested_hubs\": []\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/8003686/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=5456",
  "updated": "2026-02-14 08:25:13"
}