Electromagnetic Field Analysis of Low-Magnitude High-Frequency Vibrator with Multiple Plungers.

Zhimin Chen, Mang I Vai, Sio Hang Pun, Peng Un Mak

PAPERpubmedAnnual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference2018engineeringEffect: unclearEvidence: Insufficient

Abstract

Low-magnitude high-frequency (LMHF) of vibrational stimulation has been accepted as an effective method to enhance bone remolding. However, the electromagnetic field (EMF) generated by the vibrator could also be an influence factor in the vibrational experiments. This phenomenon underlies the bone remodeling effect caused by vibrational stimulation is disrupted to be investigated. This paper presents a design of LMHF vibrator with multiple plungers to generate vibrational stimulation with ultra low magnetic flux density to minimize the biological effect caused by the EMF. The EMF is analyzed in finite element method (FEM) using COMSOL.

AI evidence extraction

At a glance
Study type
engineering
Effect direction
unclear
Population
—
Sample size
—
Exposure
LMHF vibrator with multiple plungers (vibrational stimulation device)
Evidence strength
Insufficient
Confidence: 74% · Peer-reviewed: yes

Main findings

The paper presents a design of a low-magnitude high-frequency vibrator with multiple plungers intended to generate vibrational stimulation with ultra low magnetic flux density to minimize potential biological effects from device-generated EMF. EMF was analyzed using finite element modeling (COMSOL).

Outcomes measured

  • Electromagnetic field (EMF) characteristics / magnetic flux density of a low-magnitude high-frequency vibrator design

Limitations

  • No quantitative EMF levels or comparison values are provided in the abstract.
  • No biological or clinical outcomes are reported in the abstract (engineering/design focus).
  • Exposure parameters (e.g.
  • frequency
  • field strength metrics beyond 'magnetic flux density') are not specified in the abstract.
View raw extracted JSON
{
  "study_type": "engineering",
  "exposure": {
    "band": null,
    "source": "LMHF vibrator with multiple plungers (vibrational stimulation device)",
    "frequency_mhz": null,
    "sar_wkg": null,
    "duration": null
  },
  "population": null,
  "sample_size": null,
  "outcomes": [
    "Electromagnetic field (EMF) characteristics / magnetic flux density of a low-magnitude high-frequency vibrator design"
  ],
  "main_findings": "The paper presents a design of a low-magnitude high-frequency vibrator with multiple plungers intended to generate vibrational stimulation with ultra low magnetic flux density to minimize potential biological effects from device-generated EMF. EMF was analyzed using finite element modeling (COMSOL).",
  "effect_direction": "unclear",
  "limitations": [
    "No quantitative EMF levels or comparison values are provided in the abstract.",
    "No biological or clinical outcomes are reported in the abstract (engineering/design focus).",
    "Exposure parameters (e.g., frequency, field strength metrics beyond 'magnetic flux density') are not specified in the abstract."
  ],
  "evidence_strength": "insufficient",
  "confidence": 0.74,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "electromagnetic field",
    "magnetic flux density",
    "finite element method",
    "COMSOL",
    "vibrational stimulation",
    "low-magnitude high-frequency",
    "bone remodeling",
    "device design"
  ],
  "suggested_hubs": []
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.