Share

A Single Exposure to GSM-1800 MHz Signals in the Course of an Acute Neuroinflammatory Reaction can Alter Neuronal Responses and Microglial Morphology in the Rat Primary Auditory Cortex.

Florian Occelli, Julie Lameth, Victor Adenis, Chloé Huetz, Philippe Lévêque, Thérèse M Jay, Jean-Marc Edeline, Michel Mallat

PAPERpubmedNeuroscience2018Animal studyEffect: mixedEvidence: Low

Abstract

During mobile phone conversations, the temporal lobe neural networks involved in processing auditory information are exposed to electromagnetic fields (EMF) such as pulse-modulated GSM-1800 MHz radiofrequencies that convey wireless communications. The effects of these EMF on the brain affected by a pathological condition remain little investigated. In this study, rats injected with lipopolysaccharide (LPS) to induce neuroinflammation were exposed "head-only" to GSM-1800 MHz signals for two hours at a specific absorption rate (SAR) that reached an average value of 1.55 W/kg in the auditory cortex (ACx). Immunodetection of Iba1, a microglial marker, and electrophysiological recordings in the ACx three to six hours after global system for communication (GSM) exposure, or sham-exposure, showed that exposure to GSM-1800 MHz resulted in a growth of microglial processes and a reduction in spontaneous firing rate. More importantly, there was a significant reduction in evoked responses to artificial and natural stimuli and an increase in response duration. The response latency and the bandwidth of the frequency tuning were unchanged, but the GSM exposure led to a higher proportion of cortical sites exhibiting abnormally high acoustic thresholds. These modifications were not observed in rats exposed to GSM-1800 MHz without pretreatment with LPS. Together our data provide evidence that in neuroinflammatory conditions, acute exposure to GSM-1800 MHz can significantly affect microglia and neuronal activity underling auditory perception.

AI evidence extraction

At a glance
Study type
Animal study
Effect direction
mixed
Population
Rats with LPS-induced neuroinflammation; comparison groups included sham-exposed and non-LPS-pretreated rats
Sample size
—
Exposure
RF mobile phone · 1800 MHz · 1.55 W/kg · 2 hours (single head-only exposure)
Evidence strength
Low
Confidence: 78% · Peer-reviewed: yes

Main findings

In LPS-pretreated rats, a single 2-hour head-only exposure to GSM-1800 MHz (average SAR 1.55 W/kg in auditory cortex) was associated with growth of microglial processes, reduced spontaneous firing rate, reduced evoked responses, and increased response duration measured 3–6 hours post-exposure. Response latency and frequency tuning bandwidth were unchanged, but a higher proportion of cortical sites showed abnormally high acoustic thresholds. These modifications were not observed in rats exposed to GSM-1800 MHz without LPS pretreatment.

Outcomes measured

  • Microglial morphology (Iba1 immunodetection)
  • Auditory cortex electrophysiology: spontaneous firing rate
  • Evoked responses to artificial and natural auditory stimuli
  • Response duration
  • Response latency
  • Frequency tuning bandwidth
  • Acoustic thresholds (proportion of sites with abnormally high thresholds)

Limitations

  • Sample size not reported in provided abstract/metadata
  • Short follow-up window (3–6 hours post-exposure)
  • Animal model with induced neuroinflammation (LPS) may limit generalizability to humans
  • Single acute exposure only

Suggested hubs

  • who-icnirp (0.7)
    Study evaluates RF exposure with SAR metric relevant to exposure guidelines.
View raw extracted JSON
{
  "study_type": "animal",
  "exposure": {
    "band": "RF",
    "source": "mobile phone",
    "frequency_mhz": 1800,
    "sar_wkg": 1.55,
    "duration": "2 hours (single head-only exposure)"
  },
  "population": "Rats with LPS-induced neuroinflammation; comparison groups included sham-exposed and non-LPS-pretreated rats",
  "sample_size": null,
  "outcomes": [
    "Microglial morphology (Iba1 immunodetection)",
    "Auditory cortex electrophysiology: spontaneous firing rate",
    "Evoked responses to artificial and natural auditory stimuli",
    "Response duration",
    "Response latency",
    "Frequency tuning bandwidth",
    "Acoustic thresholds (proportion of sites with abnormally high thresholds)"
  ],
  "main_findings": "In LPS-pretreated rats, a single 2-hour head-only exposure to GSM-1800 MHz (average SAR 1.55 W/kg in auditory cortex) was associated with growth of microglial processes, reduced spontaneous firing rate, reduced evoked responses, and increased response duration measured 3–6 hours post-exposure. Response latency and frequency tuning bandwidth were unchanged, but a higher proportion of cortical sites showed abnormally high acoustic thresholds. These modifications were not observed in rats exposed to GSM-1800 MHz without LPS pretreatment.",
  "effect_direction": "mixed",
  "limitations": [
    "Sample size not reported in provided abstract/metadata",
    "Short follow-up window (3–6 hours post-exposure)",
    "Animal model with induced neuroinflammation (LPS) may limit generalizability to humans",
    "Single acute exposure only"
  ],
  "evidence_strength": "low",
  "confidence": 0.78,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "GSM-1800",
    "1800 MHz",
    "radiofrequency",
    "RF-EMF",
    "head-only exposure",
    "specific absorption rate",
    "SAR",
    "auditory cortex",
    "neuroinflammation",
    "lipopolysaccharide",
    "LPS",
    "microglia",
    "Iba1",
    "electrophysiology",
    "neuronal firing",
    "auditory perception"
  ],
  "suggested_hubs": [
    {
      "slug": "who-icnirp",
      "weight": 0.25,
      "reason": "Study evaluates RF exposure with SAR metric relevant to exposure guidelines."
    }
  ]
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.

NNEMF synthesis

Synthesis pending.

Original record: rfsafe.org paper 5529

A Single Exposure to GSM-1800 MHz Signals in the Course of an Acute Neuroinflammatory Reaction can Alter Neuronal Responses and Microglial Morphology in the Rat Primary Auditory Cortex. · Non-native EMF