  "id": 5567,
  "url": "https://nnemf.org/research/5567-effect-of-exposure-to-a-radiofrequency-electromagnetic-field",
  "title": "Effect of Exposure to a Radiofrequency Electromagnetic Field on Body Temperature in Anesthetized and Non-Anesthetized Rats.",
  "authors": [
    "Hye Sun Kim",
    "Yu Hee Lee",
    "Hyung-Do Choi",
    "Ae-Kyoung Lee",
    "Sang Bong Jeon",
    "Jeong-Ki Pack",
    "Nam Kim",
    "Young Hwan Ahn"
  ],
  "journal": "Bioelectromagnetics",
  "year": "2020",
  "doi": "10.1002/bem.22236",
  "pmid": "31828817",
  "abstract": "Exposure to a radiofrequency (RF) signal at a specific absorption rate (SAR) of 4 W/kg can increase the body temperature by more than 1 °C. In this study, we investigated the effect of anesthesia on the body temperature of rats after exposure to an RF electromagnetic field at 4 W/kg SAR. We also evaluated the influence of body mass on rats' body temperature. Rats weighing 225 and 339 g were divided into sham- and RF-exposure groups. Each of the resulting four groups was subdivided into anesthetized and non-anesthetized groups. The free-moving rats in the four RF-exposure groups were subjected to a 915 MHz RF identification signal at 4 W/kg whole-body SAR for 8 h. The rectal temperature was measured at 1-h intervals during RF exposure using a small-animal temperature probe. The body temperatures of non-anesthetized, mobile 225 and 339 g rats were not significantly affected by exposure to an RF signal. However, the body temperatures of anesthetized 225 and 339 g rats increased by 1.9 °C and 3.3 °C from baseline at 5 and 6 h of RF exposure, respectively. Three of the five 339 g anesthetized and exposed rats died after 6 h of RF exposure. Thus, anesthesia and body mass influenced RF exposure-induced changes in the body temperature of rats. Bioelectromagnetics. 2020;41:104-112.",
  "effect": "harm",
  "evidence": "low",
  "extraction": {
    "studyType": "animal",
    "studyTypeLabel": "Animal study",
    "effectDirection": "harm",
    "evidenceLabel": "Low",
    "population": "Rats (225 g and 339 g; anesthetized and non-anesthetized; sham and RF-exposed)",
    "sampleSize": "—",
    "exposure": "RF RF identification signal · 915 MHz · 4 W/kg · 8 h",
    "confidencePct": "78",
    "peerReviewed": "yes",
    "mainFindings": "Free-moving (non-anesthetized) rats (225 g and 339 g) were not significantly affected in body temperature by 915 MHz RF exposure at 4 W/kg whole-body SAR. In anesthetized rats, body temperature increased from baseline by 1.9 °C (225 g) and 3.3 °C (339 g) at 5–6 h of RF exposure, and 3 of 5 anesthetized 339 g exposed rats died after 6 h.",
    "outcomes": [
      "Rectal body temperature during exposure",
      "Mortality in exposed anesthetized rats"
    ],
    "limitations": [
      "Total sample size not reported in the abstract (only a subgroup count is given for one group)",
      "Findings are from rats and may not generalize to humans",
      "Exposure conditions are specific (915 MHz",
      "4 W/kg whole-body SAR",
      "8 h)"
    ],
    "keywords": [
      "radiofrequency",
      "RF",
      "915 MHz",
      "RFID",
      "specific absorption rate",
      "SAR",
      "whole-body exposure",
      "anesthesia",
      "body temperature",
      "rectal temperature",
      "rats",
      "mortality"
    ],
    "hubs": [],
    "raw": "{\n  \"study_type\": \"animal\",\n  \"exposure\": {\n    \"band\": \"RF\",\n    \"source\": \"RF identification signal\",\n    \"frequency_mhz\": 915,\n    \"sar_wkg\": 4,\n    \"duration\": \"8 h\"\n  },\n  \"population\": \"Rats (225 g and 339 g; anesthetized and non-anesthetized; sham and RF-exposed)\",\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"Rectal body temperature during exposure\",\n    \"Mortality in exposed anesthetized rats\"\n  ],\n  \"main_findings\": \"Free-moving (non-anesthetized) rats (225 g and 339 g) were not significantly affected in body temperature by 915 MHz RF exposure at 4 W/kg whole-body SAR. In anesthetized rats, body temperature increased from baseline by 1.9 °C (225 g) and 3.3 °C (339 g) at 5–6 h of RF exposure, and 3 of 5 anesthetized 339 g exposed rats died after 6 h.\",\n  \"effect_direction\": \"harm\",\n  \"limitations\": [\n    \"Total sample size not reported in the abstract (only a subgroup count is given for one group)\",\n    \"Findings are from rats and may not generalize to humans\",\n    \"Exposure conditions are specific (915 MHz, 4 W/kg whole-body SAR, 8 h)\"\n  ],\n  \"evidence_strength\": \"low\",\n  \"confidence\": 0.78,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"radiofrequency\",\n    \"RF\",\n    \"915 MHz\",\n    \"RFID\",\n    \"specific absorption rate\",\n    \"SAR\",\n    \"whole-body exposure\",\n    \"anesthesia\",\n    \"body temperature\",\n    \"rectal temperature\",\n    \"rats\",\n    \"mortality\"\n  ],\n  \"suggested_hubs\": []\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/31828817/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=5567",
  "updated": "2026-02-14 08:47:29"
}