  "id": 5685,
  "url": "https://nnemf.org/research/5685-modelling-and-evaluation-of-the-absorption-of-the",
  "title": "Modelling and Evaluation of the Absorption of the 866 MHz Electromagnetic Field in Humans Exposed near to Fixed I-RFID Readers Used in Medical RTLS or to Monitor PPE.",
  "authors": [
    "Patryk Zradziński",
    "Jolanta Karpowicz",
    "Krzysztof Gryz",
    "Grzegorz Owczarek",
    "Victoria Ramos"
  ],
  "journal": "Sensors (Basel, Switzerland)",
  "year": "2021",
  "doi": "10.3390/s21124251",
  "pmid": "34205808",
  "abstract": "The aim of this study was to model and evaluate the Specific Energy Absorption Rate (SAR) values in humans in proximity to fixed multi-antenna I-RFID readers of passive tags under various scenarios mimicking exposure when they are incorporated in Real-Time Location Systems (RTLS), or used to monitor Personal Protective Equipment (PPE). The sources of the electromagnetic field (EMF) in the modelled readers were rectangular microstrip antennas at a resonance frequency in free space of 866 MHz from the ultra-high frequency (UHF) RFID frequency range of 865-868 MHz. The obtained results of numerical modelling showed that the SAR values in the body 5 cm away from the UHF RFID readers need consideration with respect to exposure limits set by international guidelines to prevent adverse thermal effects of exposure to EMF: when the effective radiated power exceeds 5.5 W with respect to the general public/unrestricted environments exposure limits, and with respect to occupational/restricted environments exposure limits, when the effective radiated power exceeds 27.5 W.",
  "effect": "unclear",
  "evidence": "insufficient",
  "extraction": {
    "studyType": "engineering",
    "studyTypeLabel": "engineering",
    "effectDirection": "unclear",
    "evidenceLabel": "Insufficient",
    "population": "Humans (modelled)",
    "sampleSize": "—",
    "exposure": "RF I-RFID reader (UHF RFID) · 866 MHz",
    "confidencePct": "74",
    "peerReviewed": "yes",
    "mainFindings": "Numerical modelling of exposure near fixed multi-antenna UHF RFID readers (866 MHz) indicated that SAR values at 5 cm distance warrant consideration relative to international exposure limits. The study reports that effective radiated power above 5.5 W may exceed general public/unrestricted environment limits, and above 27.5 W may exceed occupational/restricted environment limits.",
    "outcomes": [
      "Specific Energy Absorption Rate (SAR) in humans near fixed multi-antenna I-RFID readers",
      "Comparison to international exposure limits/guidelines for preventing adverse thermal effects"
    ],
    "limitations": [
      "Numerical modelling study (no direct measurements in humans reported in abstract)",
      "Exposure scenarios limited to proximity (5 cm) and modelled reader/antenna configurations described"
    ],
    "keywords": [
      "SAR",
      "specific energy absorption rate",
      "UHF RFID",
      "I-RFID",
      "866 MHz",
      "865-868 MHz",
      "microstrip antenna",
      "RTLS",
      "personal protective equipment",
      "occupational exposure",
      "exposure limits",
      "international guidelines"
    ],
    "hubs": [
      {
        "slug": "occupational-exposure",
        "weight": "0.7",
        "reason": "Abstract explicitly compares modelled exposure to occupational/restricted environment exposure limits."
      }
    ],
    "raw": "{\n  \"study_type\": \"engineering\",\n  \"exposure\": {\n    \"band\": \"RF\",\n    \"source\": \"I-RFID reader (UHF RFID)\",\n    \"frequency_mhz\": 866,\n    \"sar_wkg\": null,\n    \"duration\": null\n  },\n  \"population\": \"Humans (modelled)\",\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"Specific Energy Absorption Rate (SAR) in humans near fixed multi-antenna I-RFID readers\",\n    \"Comparison to international exposure limits/guidelines for preventing adverse thermal effects\"\n  ],\n  \"main_findings\": \"Numerical modelling of exposure near fixed multi-antenna UHF RFID readers (866 MHz) indicated that SAR values at 5 cm distance warrant consideration relative to international exposure limits. The study reports that effective radiated power above 5.5 W may exceed general public/unrestricted environment limits, and above 27.5 W may exceed occupational/restricted environment limits.\",\n  \"effect_direction\": \"unclear\",\n  \"limitations\": [\n    \"Numerical modelling study (no direct measurements in humans reported in abstract)\",\n    \"Exposure scenarios limited to proximity (5 cm) and modelled reader/antenna configurations described\"\n  ],\n  \"evidence_strength\": \"insufficient\",\n  \"confidence\": 0.74,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"SAR\",\n    \"specific energy absorption rate\",\n    \"UHF RFID\",\n    \"I-RFID\",\n    \"866 MHz\",\n    \"865-868 MHz\",\n    \"microstrip antenna\",\n    \"RTLS\",\n    \"personal protective equipment\",\n    \"occupational exposure\",\n    \"exposure limits\",\n    \"international guidelines\"\n  ],\n  \"suggested_hubs\": [\n    {\n      \"slug\": \"occupational-exposure\",\n      \"weight\": 0.62,\n      \"reason\": \"Abstract explicitly compares modelled exposure to occupational/restricted environment exposure limits.\"\n    }\n  ]\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/34205808/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=5685",
  "updated": "2026-02-14 08:50:29"
}