  "id": 5704,
  "url": "https://nnemf.org/research/5704-effect-of-extremely-low-frequency-electromagnetic-field-parameters",
  "title": "Effect of extremely low frequency electromagnetic field parameters on the proliferation of human breast cancer.",
  "authors": [
    "Min-Haw Wang",
    "Kuan-Wei Chen",
    "Ding-Xung Ni",
    "Hao-Jha Fang",
    "Ling-Sheng Jang",
    "Chun-Hong Chen"
  ],
  "journal": "Electromagnetic biology and medicine",
  "year": "2021",
  "doi": "10.1080/15368378.2021.1891093",
  "pmid": "33632057",
  "abstract": "Extremely low-frequency electromagnetic field (ELF-EMF) exposures influence many biological systems. These effects are mainly related to the intensity, duration, frequency, and pattern of the ELF-EMF. Our intent was to characterize the effect of specific pulsed electromagnetic fields on the in vitro proliferation of MCF-7 adenocarcinoma and MDA-MB-231 breast cancer cell lines and one non-cancerous M10 breast epithelial cell line. The following four important parameters of ELF-EMF were examined: frequencies (7.83 ± 0.3, 23.49 ± 0.3, and 39.15 ± 0.3 Hz), flux density (0.5 and 1 mT), exposure duration (12, 24, and 48 h), and the exposure methodology (continuous exposure versus switching exposure). The viability of MDA-MB-231 cells exposed to the optimized ELF-EMF pattern (7.83 ± 0.3 Hz, 1 mT, and 6 h switching exposure) was 40.1%. By contrast, the optimized ELF-EMF parameters that were most cytotoxic to breast cancer MDA-MB-231 cells were not damaging to normal M10 cells. In vitro studies also showed that exposure of MDA-MB-231 cells to the optimized ELF-EMF pattern promoted Ca influx and resulted in apoptosis. These data confirm that exposure to this specific ELF-EMF pattern can influence cellular processes and inhibit cancer cell growth. The specific ELF-EMF pattern determined in this study may provide a potential anti-cancer treatment in the future.",
  "effect": "benefit",
  "evidence": "low",
  "extraction": {
    "studyType": "in_vitro",
    "studyTypeLabel": "In vitro study",
    "effectDirection": "benefit",
    "evidenceLabel": "Low",
    "population": "Human breast cancer cell lines (MCF-7, MDA-MB-231) and non-cancerous breast epithelial cell line (M10) in vitro",
    "sampleSize": "—",
    "exposure": "ELF · 12, 24, and 48 h (tested); optimized pattern included 6 h switching exposure",
    "confidencePct": "78",
    "peerReviewed": "yes",
    "mainFindings": "Pulsed ELF-EMF parameters (frequency, flux density, duration, and exposure methodology) were evaluated for effects on in vitro proliferation/viability of MCF-7 and MDA-MB-231 breast cancer cells and M10 normal breast epithelial cells. An optimized switching exposure pattern (7.83 ± 0.3 Hz, 1 mT, 6 h switching exposure) reduced MDA-MB-231 cell viability to 40.1% and was reported as not damaging to M10 cells; in MDA-MB-231 cells it promoted Ca influx and resulted in apoptosis.",
    "outcomes": [
      "Cell proliferation/viability",
      "Cytotoxicity to cancer vs normal cells",
      "Calcium (Ca) influx",
      "Apoptosis"
    ],
    "limitations": [
      "In vitro cell-line study",
      "findings may not translate to in vivo or clinical outcomes",
      "Sample size/replication and statistical details not provided in abstract",
      "Exposure source/device and detailed dosimetry beyond frequency/flux density not described in abstract"
    ],
    "keywords": [
      "ELF-EMF",
      "pulsed electromagnetic field",
      "breast cancer",
      "MCF-7",
      "MDA-MB-231",
      "M10",
      "frequency",
      "flux density",
      "switching exposure",
      "cell viability",
      "calcium influx",
      "apoptosis"
    ],
    "hubs": [],
    "raw": "{\n  \"study_type\": \"in_vitro\",\n  \"exposure\": {\n    \"band\": \"ELF\",\n    \"source\": null,\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": \"12, 24, and 48 h (tested); optimized pattern included 6 h switching exposure\"\n  },\n  \"population\": \"Human breast cancer cell lines (MCF-7, MDA-MB-231) and non-cancerous breast epithelial cell line (M10) in vitro\",\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"Cell proliferation/viability\",\n    \"Cytotoxicity to cancer vs normal cells\",\n    \"Calcium (Ca) influx\",\n    \"Apoptosis\"\n  ],\n  \"main_findings\": \"Pulsed ELF-EMF parameters (frequency, flux density, duration, and exposure methodology) were evaluated for effects on in vitro proliferation/viability of MCF-7 and MDA-MB-231 breast cancer cells and M10 normal breast epithelial cells. An optimized switching exposure pattern (7.83 ± 0.3 Hz, 1 mT, 6 h switching exposure) reduced MDA-MB-231 cell viability to 40.1% and was reported as not damaging to M10 cells; in MDA-MB-231 cells it promoted Ca influx and resulted in apoptosis.\",\n  \"effect_direction\": \"benefit\",\n  \"limitations\": [\n    \"In vitro cell-line study; findings may not translate to in vivo or clinical outcomes\",\n    \"Sample size/replication and statistical details not provided in abstract\",\n    \"Exposure source/device and detailed dosimetry beyond frequency/flux density not described in abstract\"\n  ],\n  \"evidence_strength\": \"low\",\n  \"confidence\": 0.78,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"ELF-EMF\",\n    \"pulsed electromagnetic field\",\n    \"breast cancer\",\n    \"MCF-7\",\n    \"MDA-MB-231\",\n    \"M10\",\n    \"frequency\",\n    \"flux density\",\n    \"switching exposure\",\n    \"cell viability\",\n    \"calcium influx\",\n    \"apoptosis\"\n  ],\n  \"suggested_hubs\": []\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/33632057/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=5704",
  "updated": "2026-02-14 08:50:52"
}