  "id": 5817,
  "url": "https://nnemf.org/research/5817-dose-estimation-for-indoor-radon-occupational-radiation-and",
  "title": "Dose Estimation for Indoor Radon, Occupational Radiation, and Electromagnetic Field Exposure in a Nuclear Medicine Department in Turkiye.",
  "authors": [
    "T Sahmaran",
    "S Nur",
    "H I Atılgan",
    "H Peker"
  ],
  "journal": "Health physics",
  "year": "2025",
  "doi": "10.1097/hp.0000000000001934",
  "pmid": "39656106",
  "abstract": "In this study, the occupational radiation dose, radon gas, and non-ionizing radiation doses originating from electromagnetic fields (EMF) to which radiation workers are exposed were monitored and evaluated for 1 y. Using electronic personnel dosimeters (EPD), average daily radiation doses based on the number of patients and annual average effective dose results of radiation workers were obtained over a period of 1 y. Also, the annual effective dose and risk values were calculated for 8 h and 24 h by taking radon gas measurements at 2-mo intervals in the nuclear medicine department. Finally, electric field measurements were made one day a week in the selected areas. All the results obtained were compared with national and international dose limits. The results obtained as a result of EPD, radon gas, and EMF measurements made in the nuclear medicine department were found to be far below the international and national legal dose limits.",
  "effect": "no_effect",
  "evidence": "low",
  "extraction": {
    "studyType": "exposure_assessment",
    "studyTypeLabel": "exposure assessment",
    "effectDirection": "no_effect",
    "evidenceLabel": "Low",
    "population": "Radiation workers in a nuclear medicine department in Turkiye",
    "sampleSize": "—",
    "exposure": "occupational · 1 y (radiation dose monitoring); radon measured at 2-mo intervals; electric field measured 1 day/week",
    "confidencePct": "74",
    "peerReviewed": "yes",
    "mainFindings": "Over 1 year of monitoring in a nuclear medicine department, results from electronic personnel dosimeters, radon gas measurements, and electric field (EMF) measurements were reported to be far below national and international legal dose limits.",
    "outcomes": [
      "Occupational radiation dose (effective dose)",
      "Indoor radon gas measurements (annual effective dose and risk for 8 h and 24 h)",
      "Electric field measurements (EMF exposure)",
      "Comparison to national and international dose limits"
    ],
    "limitations": [
      "Sample size not reported in abstract",
      "EMF exposure characterized only by electric field measurements (frequency/source details not provided)",
      "Electric field measurements performed one day per week (may not capture full temporal variability)",
      "No health outcomes assessed",
      "focus is on exposure/dose relative to limits"
    ],
    "keywords": [
      "occupational exposure",
      "nuclear medicine department",
      "electronic personnel dosimeter",
      "radon",
      "non-ionizing radiation",
      "electromagnetic fields",
      "electric field measurements",
      "dose limits",
      "Turkiye"
    ],
    "hubs": [
      {
        "slug": "occupational-exposure",
        "weight": "0.7",
        "reason": "Assesses occupational EMF (electric field) exposure and compares to limits in a nuclear medicine workplace."
      }
    ],
    "raw": "{\n  \"study_type\": \"exposure_assessment\",\n  \"exposure\": {\n    \"band\": null,\n    \"source\": \"occupational\",\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": \"1 y (radiation dose monitoring); radon measured at 2-mo intervals; electric field measured 1 day/week\"\n  },\n  \"population\": \"Radiation workers in a nuclear medicine department in Turkiye\",\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"Occupational radiation dose (effective dose)\",\n    \"Indoor radon gas measurements (annual effective dose and risk for 8 h and 24 h)\",\n    \"Electric field measurements (EMF exposure)\",\n    \"Comparison to national and international dose limits\"\n  ],\n  \"main_findings\": \"Over 1 year of monitoring in a nuclear medicine department, results from electronic personnel dosimeters, radon gas measurements, and electric field (EMF) measurements were reported to be far below national and international legal dose limits.\",\n  \"effect_direction\": \"no_effect\",\n  \"limitations\": [\n    \"Sample size not reported in abstract\",\n    \"EMF exposure characterized only by electric field measurements (frequency/source details not provided)\",\n    \"Electric field measurements performed one day per week (may not capture full temporal variability)\",\n    \"No health outcomes assessed; focus is on exposure/dose relative to limits\"\n  ],\n  \"evidence_strength\": \"low\",\n  \"confidence\": 0.74,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"occupational exposure\",\n    \"nuclear medicine department\",\n    \"electronic personnel dosimeter\",\n    \"radon\",\n    \"non-ionizing radiation\",\n    \"electromagnetic fields\",\n    \"electric field measurements\",\n    \"dose limits\",\n    \"Turkiye\"\n  ],\n  \"suggested_hubs\": [\n    {\n      \"slug\": \"occupational-exposure\",\n      \"weight\": 0.9,\n      \"reason\": \"Assesses occupational EMF (electric field) exposure and compares to limits in a nuclear medicine workplace.\"\n    }\n  ]\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/39656106/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=5817",
  "updated": "2026-02-14 08:53:29"
}