EMF biological effects
Share

Decreased body weight in fetal rats after irradiation with 2450-MHz (CW) microwaves.

E Berman, H B Carter

PAPERpubmedHealth physics1984Animal studyEffect: harmEvidence: Low

Abstract

Female Sprague-Dawley (CD) rats were exposed to 2450-MHz (CW) microwave radiation at incident power densities of 0 or 40 mW/cm2 (SAR = 6.0 W/kg) for 100 min daily on the sixth through 15th day of gestation. One-time exposure to the same conditions increased average colonic temperatures 2 degrees C at the end of irradiation in pregnant rats of similar size. There were 23 sham-irradiated and 24 microwave-irradiated females. When these groups were compared on the 21st day of gestation, no significant differences were found in pregnancy rates; in the numbers of live, dead or total fetuses; nor in the incidences of external, visceral or skeletal anomalies or variations. However, mean fetal body weight was significantly (p = 0.0008) lower after microwave irradiation and was 9% less than that of sham-irradiated litters. Sternal ossification was also significantly delayed in the microwave-irradiated fetuses (p = 0.007). It is concluded that even though a change in the malformation rate is not effected in rats, a fetotoxic effect does occur due to microwave-exposure conditions which raise maternal rectal temperatures to approx. 40 degrees C and produce a specific absorption rate (SAR) greater than or equal to 6 W/kg in the dam.

AI evidence extraction

At a glance
Study type
Animal study
Effect direction
harm
Population
Pregnant female Sprague-Dawley (CD) rats and their fetuses
Sample size
47
Exposure
microwave · 2450 MHz · 6 W/kg · 100 min daily on gestation days 6–15 (one-time exposure also described for temperature change)
Evidence strength
Low
Confidence: 86% · Peer-reviewed: yes

Main findings

Compared with sham irradiation (0 mW/cm2), exposure to 2450-MHz continuous-wave microwaves at 40 mW/cm2 (SAR 6.0 W/kg) for 100 min/day on gestation days 6–15 produced significantly lower mean fetal body weight (9% lower; p=0.0008) and significantly delayed sternal ossification (p=0.007) on gestation day 21. No significant differences were reported for pregnancy rates, numbers of live/dead/total fetuses, or incidences of external, visceral, or skeletal anomalies/variations.

Outcomes measured

  • pregnancy rate
  • number of live fetuses
  • number of dead fetuses
  • total fetuses
  • external anomalies/variations
  • visceral anomalies/variations
  • skeletal anomalies/variations
  • fetal body weight
  • sternal ossification delay
  • maternal colonic/rectal temperature change

Limitations

  • Mechanistic attribution to heating is suggested but not experimentally separated from non-thermal effects in the abstract
  • Only one exposure level (40 mW/cm2
  • SAR 6 W/kg) is described
  • Details on randomization/blinding and litter-level statistical handling are not provided in the abstract

Suggested hubs

  • who-icnirp (0.7)
    Animal study reports effects at SAR 6 W/kg with maternal temperature elevation, relevant to exposure guideline discussions.
View raw extracted JSON
{
  "study_type": "animal",
  "exposure": {
    "band": "microwave",
    "source": null,
    "frequency_mhz": 2450,
    "sar_wkg": 6,
    "duration": "100 min daily on gestation days 6–15 (one-time exposure also described for temperature change)"
  },
  "population": "Pregnant female Sprague-Dawley (CD) rats and their fetuses",
  "sample_size": 47,
  "outcomes": [
    "pregnancy rate",
    "number of live fetuses",
    "number of dead fetuses",
    "total fetuses",
    "external anomalies/variations",
    "visceral anomalies/variations",
    "skeletal anomalies/variations",
    "fetal body weight",
    "sternal ossification delay",
    "maternal colonic/rectal temperature change"
  ],
  "main_findings": "Compared with sham irradiation (0 mW/cm2), exposure to 2450-MHz continuous-wave microwaves at 40 mW/cm2 (SAR 6.0 W/kg) for 100 min/day on gestation days 6–15 produced significantly lower mean fetal body weight (9% lower; p=0.0008) and significantly delayed sternal ossification (p=0.007) on gestation day 21. No significant differences were reported for pregnancy rates, numbers of live/dead/total fetuses, or incidences of external, visceral, or skeletal anomalies/variations.",
  "effect_direction": "harm",
  "limitations": [
    "Mechanistic attribution to heating is suggested but not experimentally separated from non-thermal effects in the abstract",
    "Only one exposure level (40 mW/cm2; SAR 6 W/kg) is described",
    "Details on randomization/blinding and litter-level statistical handling are not provided in the abstract"
  ],
  "evidence_strength": "low",
  "confidence": 0.86,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "2450 MHz",
    "microwave",
    "continuous wave",
    "CW",
    "pregnancy",
    "gestation",
    "rat",
    "fetal weight",
    "ossification",
    "SAR",
    "hyperthermia",
    "teratology"
  ],
  "suggested_hubs": [
    {
      "slug": "who-icnirp",
      "weight": 0.25,
      "reason": "Animal study reports effects at SAR 6 W/kg with maternal temperature elevation, relevant to exposure guideline discussions."
    }
  ]
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.

NNEMF synthesis

Synthesis pending.

Original record: rfsafe.org paper 5922

Decreased body weight in fetal rats after irradiation with 2450-MHz (CW) microwaves. · Non-native EMF