  "id": 5944,
  "url": "https://nnemf.org/research/5944-microwave-radiation-injury",
  "title": "Microwave radiation injury.",
  "authors": [
    "J E Tintinalli",
    "G Krause",
    "E Gursel"
  ],
  "journal": "Annals of emergency medicine",
  "year": "1983",
  "doi": "10.1016/s0196-0644(83)80215-7",
  "pmid": "6625269",
  "abstract": "A case of momentary exposure of the right hand to irradiation from a microwave oven is described. Transient paresthesias and a cold, pale hand resulted but resolved spontaneously in 60 minutes without treatment. Even momentary exposure can result in severe coagulation necrosis, with eventual loss of the exposed extremity.",
  "effect": "harm",
  "evidence": "very_low",
  "extraction": {
    "studyType": "case_report",
    "studyTypeLabel": "Case report",
    "effectDirection": "harm",
    "evidenceLabel": "Very low",
    "population": "—",
    "sampleSize": "1",
    "exposure": "microwave microwave oven · momentary",
    "confidencePct": "74",
    "peerReviewed": "yes",
    "mainFindings": "A single case described momentary exposure of the right hand to microwave oven irradiation, resulting in transient paresthesias and a cold, pale hand that resolved spontaneously within 60 minutes without treatment. The report notes that even momentary exposure can result in severe coagulation necrosis with possible eventual loss of the exposed extremity.",
    "outcomes": [
      "Transient paresthesias",
      "Cold",
      "pale hand",
      "Coagulation necrosis (potential severe injury)",
      "Loss of exposed extremity (potential outcome)"
    ],
    "limitations": [
      "Single case report",
      "No exposure metrics reported (e.g.",
      "frequency",
      "power",
      "SAR)",
      "Causal inference limited by lack of controls and potential confounding",
      "Short follow-up for the described case (symptoms resolved within 60 minutes)"
    ],
    "keywords": [
      "microwave radiation",
      "microwave oven",
      "hand exposure",
      "paresthesia",
      "thermal injury",
      "coagulation necrosis",
      "case report"
    ],
    "hubs": [],
    "raw": "{\n  \"study_type\": \"case_report\",\n  \"exposure\": {\n    \"band\": \"microwave\",\n    \"source\": \"microwave oven\",\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": \"momentary\"\n  },\n  \"population\": null,\n  \"sample_size\": 1,\n  \"outcomes\": [\n    \"Transient paresthesias\",\n    \"Cold, pale hand\",\n    \"Coagulation necrosis (potential severe injury)\",\n    \"Loss of exposed extremity (potential outcome)\"\n  ],\n  \"main_findings\": \"A single case described momentary exposure of the right hand to microwave oven irradiation, resulting in transient paresthesias and a cold, pale hand that resolved spontaneously within 60 minutes without treatment. The report notes that even momentary exposure can result in severe coagulation necrosis with possible eventual loss of the exposed extremity.\",\n  \"effect_direction\": \"harm\",\n  \"limitations\": [\n    \"Single case report\",\n    \"No exposure metrics reported (e.g., frequency, power, SAR)\",\n    \"Causal inference limited by lack of controls and potential confounding\",\n    \"Short follow-up for the described case (symptoms resolved within 60 minutes)\"\n  ],\n  \"evidence_strength\": \"very_low\",\n  \"confidence\": 0.74,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"microwave radiation\",\n    \"microwave oven\",\n    \"hand exposure\",\n    \"paresthesia\",\n    \"thermal injury\",\n    \"coagulation necrosis\",\n    \"case report\"\n  ],\n  \"suggested_hubs\": []\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/6625269/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=5944",
  "updated": "2026-02-15 23:47:43"
}