Share

Design idea for a microwave energy coupler in biomedical field.

M Bramanti

PAPERpubmedJournal of biomedical engineering1983engineeringEffect: unclearEvidence: Insufficient

Abstract

The use of microwave radiation for biomedical purposes has been increasing in recent years. Among the most important applications are localized hyperthermia, noninvasive diagnosis and monitoring of cardiovascular system parameters and characterization of biological tissues. For all these purposes the design of suitable electromagnetic (e.m.) energy couplers is of fundamental importance. In this paper a new structure is suggested and assessed for a direct contact microwave applicator. The proposed radiating system is obtained using the microstrip transmission lines technique and its principal characteristics are very small sizes and weight, together with good matching and sufficiently defined and small irradiated value.

AI evidence extraction

At a glance
Study type
engineering
Effect direction
unclear
Population
—
Sample size
—
Exposure
microwave
Evidence strength
Insufficient
Confidence: 66% · Peer-reviewed: yes

Main findings

A new microstrip transmission-line based structure is proposed and assessed for a direct-contact microwave applicator. The design is described as having very small size and weight, good matching, and a sufficiently defined and small irradiated value.

Outcomes measured

  • Design/assessment of an electromagnetic energy coupler (microwave applicator) for biomedical uses
  • Device characteristics (size/weight
  • matching
  • irradiated area/value)
View raw extracted JSON
{
  "study_type": "engineering",
  "exposure": {
    "band": "microwave",
    "source": "direct contact microwave applicator",
    "frequency_mhz": null,
    "sar_wkg": null,
    "duration": null
  },
  "population": null,
  "sample_size": null,
  "outcomes": [
    "Design/assessment of an electromagnetic energy coupler (microwave applicator) for biomedical uses",
    "Device characteristics (size/weight, matching, irradiated area/value)"
  ],
  "main_findings": "A new microstrip transmission-line based structure is proposed and assessed for a direct-contact microwave applicator. The design is described as having very small size and weight, good matching, and a sufficiently defined and small irradiated value.",
  "effect_direction": "unclear",
  "limitations": [],
  "evidence_strength": "insufficient",
  "confidence": 0.66,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "microwave radiation",
    "biomedical applications",
    "localized hyperthermia",
    "noninvasive diagnosis",
    "cardiovascular monitoring",
    "tissue characterization",
    "electromagnetic energy coupler",
    "direct contact applicator",
    "microstrip transmission lines"
  ],
  "suggested_hubs": []
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.

NNEMF synthesis

Synthesis pending.

Original record: rfsafe.org paper 5946