  "title": "Dosimetry for a study of effects of 2.45-GHz microwaves on mouse testis.",
  "authors": [
    "A B Cairnie",
    "D A Hill",
    "H M Assenheim"
  ],
  "journal": "Bioelectromagnetics",
  "year": "1980",
  "doi": "10.1002/bem.2250010308",
  "pmid": "7284029",
  "abstract": "In order to determine the effects of microwave radiation on the testis, it is necessary to express the physical insult in animal studies in a way that can be replicated elsewhere and ultimately used as a basis for extrapolation to man. However, there is conflict--especially in chronic experiments--between the desire for precise dosimetry and the need to minimise alteration of the normal physiological functions of the animals. The compromise arrangement used in this study was to house the mice singly, in cages with limited food and water, and to irradiate them for up to 30 days (16 h/day) in an anechoic chamber. The only measurements taken routinely were of power density in the positions normally occupied by the cages. In addition, a series of absorption measurements was made in mouse carcasses: Whole-body specific absorption rate (SAR); energy-deposition patterns (determined thermographically); and local SAR in testis (using a miniature electric (E)-field probe). It was concluded that the SAR in testis was considerably less than the whole-body SAR. Exposure for 16 h at 50 mW/cm2 elevated rectal but not testis temperature, thus demonstrating the ability of the conscious mouse to regulate the temperature of its testis.",
  "effect": "unclear",
  "evidence": "low",
  "extraction": {
    "studyType": "animal",
    "studyTypeLabel": "Animal study",
    "effectDirection": "unclear",
    "evidenceLabel": "Low",
    "population": "mice",
    "sampleSize": "—",
    "exposure": "microwave · 2450 MHz · up to 30 days (16 h/day); also notes exposure for 16 h at 50 mW/cm2",
    "confidencePct": "74",
    "peerReviewed": "yes",
    "mainFindings": "The study measured power density at cage positions and performed absorption measurements in mouse carcasses, including whole-body SAR, energy-deposition patterns, and local SAR in testis. It concluded that SAR in the testis was considerably less than whole-body SAR. Exposure for 16 h at 50 mW/cm2 elevated rectal temperature but not testis temperature.",
    "outcomes": [
      "dosimetry (power density",
      "whole-body SAR",
      "local SAR in testis",
      "energy-deposition patterns)",
      "rectal temperature",
      "testis temperature"
    ],
    "limitations": [
      "No sample size reported in abstract",
      "Routine measurements were limited to power density at cage positions",
      "Absorption/SAR measurements were made in mouse carcasses (not in vivo)"
    ],
    "keywords": [
      "2.45 GHz",
      "microwaves",
      "mouse",
      "testis",
      "dosimetry",
      "power density",
      "specific absorption rate",
      "SAR",
      "temperature",
      "anechoic chamber"
    ],
    "hubs": [],
    "raw": "{\n  \"study_type\": \"animal\",\n  \"exposure\": {\n    \"band\": \"microwave\",\n    \"source\": null,\n    \"frequency_mhz\": 2450,\n    \"sar_wkg\": null,\n    \"duration\": \"up to 30 days (16 h/day); also notes exposure for 16 h at 50 mW/cm2\"\n  },\n  \"population\": \"mice\",\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"dosimetry (power density, whole-body SAR, local SAR in testis, energy-deposition patterns)\",\n    \"rectal temperature\",\n    \"testis temperature\"\n  ],\n  \"main_findings\": \"The study measured power density at cage positions and performed absorption measurements in mouse carcasses, including whole-body SAR, energy-deposition patterns, and local SAR in testis. It concluded that SAR in the testis was considerably less than whole-body SAR. Exposure for 16 h at 50 mW/cm2 elevated rectal temperature but not testis temperature.\",\n  \"effect_direction\": \"unclear\",\n  \"limitations\": [\n    \"No sample size reported in abstract\",\n    \"Routine measurements were limited to power density at cage positions\",\n    \"Absorption/SAR measurements were made in mouse carcasses (not in vivo)\"\n  ],\n  \"evidence_strength\": \"low\",\n  \"confidence\": 0.74,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"2.45 GHz\",\n    \"microwaves\",\n    \"mouse\",\n    \"testis\",\n    \"dosimetry\",\n    \"power density\",\n    \"specific absorption rate\",\n    \"SAR\",\n    \"temperature\",\n    \"anechoic chamber\"\n  ],\n  \"suggested_hubs\": []\n}"
  },