  "id": 6035,
  "url": "https://nnemf.org/research/6035-modification-of-the-repeated-acquisition-of-response-sequences",
  "title": "Modification of the repeated acquisition of response sequences in rats by low-level microwave exposure.",
  "authors": [
    "J Schrot",
    "J R Thomas",
    "R A Banvard"
  ],
  "journal": "Bioelectromagnetics",
  "year": "1980",
  "doi": "10.1002/bem.2250010109",
  "pmid": "7284018",
  "abstract": "The acute effects of microwave exposure on a repeated acquisition baseline were investigated in three rats. Each session the animals acquired a different four-member response sequence. Each of the first three correct responses advanced the sequence to the next member, and the fourth correct response produced food reinforcement. Incorrect responses produced a three-second timeout. Baseline and control sessions were characterized by a decrease in errors within each session. The animals were acutely exposed to a 2.8 GHz pulsed-microwave field prior to test sessions, with average power densities ranging from 0.25 to to 10 mW/cm2. In comparison to control sessions, 1/2 hour of exposure to microwave radiation at power densities of 5 and 10 mW/cm2 increased errors and altered the pattern of within-session acquisition. Exposure to the 10 mW/cm2 power density decreased the rate of sequence completion in all animals. The results of exposures at 0.25, 0.5, and 1 mW/cm2 power densities were generally within the control range. The results are interpreted as indicating a disruption in the discriminative stimulus control of the repeated acquisition behavior.",
  "effect": "harm",
  "evidence": "very_low",
  "extraction": {
    "studyType": "animal",
    "studyTypeLabel": "Animal study",
    "effectDirection": "harm",
    "evidenceLabel": "Very low",
    "population": "Three rats",
    "sampleSize": "3",
    "exposure": "microwave · 2800 MHz · 1/2 hour (acute exposure prior to test sessions)",
    "confidencePct": "78",
    "peerReviewed": "yes",
    "mainFindings": "Rats acutely exposed to a 2.8 GHz pulsed-microwave field at average power densities of 5 and 10 mW/cm2 showed increased errors and altered within-session acquisition compared with control sessions. Exposure at 10 mW/cm2 decreased the rate of sequence completion in all animals, while results at 0.25, 0.5, and 1 mW/cm2 were generally within the control range.",
    "outcomes": [
      "Repeated acquisition of response sequences (errors)",
      "Pattern of within-session acquisition",
      "Rate of sequence completion"
    ],
    "limitations": [
      "Very small sample size (three rats)",
      "Acute exposure only",
      "no long-term effects assessed",
      "Exposure metric reported as power density",
      "SAR not reported"
    ],
    "keywords": [
      "microwave",
      "pulsed microwave",
      "2.8 GHz",
      "2800 MHz",
      "power density",
      "mW/cm2",
      "rats",
      "behavior",
      "learning",
      "repeated acquisition",
      "response sequences"
    ],
    "hubs": [],
    "raw": "{\n  \"study_type\": \"animal\",\n  \"exposure\": {\n    \"band\": \"microwave\",\n    \"source\": null,\n    \"frequency_mhz\": 2800,\n    \"sar_wkg\": null,\n    \"duration\": \"1/2 hour (acute exposure prior to test sessions)\"\n  },\n  \"population\": \"Three rats\",\n  \"sample_size\": 3,\n  \"outcomes\": [\n    \"Repeated acquisition of response sequences (errors)\",\n    \"Pattern of within-session acquisition\",\n    \"Rate of sequence completion\"\n  ],\n  \"main_findings\": \"Rats acutely exposed to a 2.8 GHz pulsed-microwave field at average power densities of 5 and 10 mW/cm2 showed increased errors and altered within-session acquisition compared with control sessions. Exposure at 10 mW/cm2 decreased the rate of sequence completion in all animals, while results at 0.25, 0.5, and 1 mW/cm2 were generally within the control range.\",\n  \"effect_direction\": \"harm\",\n  \"limitations\": [\n    \"Very small sample size (three rats)\",\n    \"Acute exposure only; no long-term effects assessed\",\n    \"Exposure metric reported as power density; SAR not reported\"\n  ],\n  \"evidence_strength\": \"very_low\",\n  \"confidence\": 0.78,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"microwave\",\n    \"pulsed microwave\",\n    \"2.8 GHz\",\n    \"2800 MHz\",\n    \"power density\",\n    \"mW/cm2\",\n    \"rats\",\n    \"behavior\",\n    \"learning\",\n    \"repeated acquisition\",\n    \"response sequences\"\n  ],\n  \"suggested_hubs\": []\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/7284018/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=6035",
  "updated": "2026-02-16 00:08:37"
}