  "id": 6046,
  "url": "https://nnemf.org/research/6046-microwave-radiation-and-heart-beat-rate-of-rabbits",
  "title": "Microwave radiation and heart-beat rate of rabbits.",
  "authors": [
    "C K Chou",
    "L F Han",
    "A W Guy"
  ],
  "journal": "The Journal of microwave power",
  "year": "1980",
  "doi": null,
  "pmid": "6904510",
  "abstract": "Each of three adult New Zealand rabbits, 2 male and 1 female albinos, was exposed dorsally or ventrally, to 2450-MHz plane waves for 20 min under each of several field conditions: 1) to continuous waves (CW) at 5 mW/cm2; 2) to pulsed waves (PW) of 1-microsecond width that recurred 700 pps at an average of 5 mW/cm2 and at a peak of 7.1 W/cm2; 3) to PW of 10-microseconds width at a peak of 13.7 W/cm2 that were synchronized with and triggered by the R wave of the electrocardiogram (EKG) at various delay times (0, 100, and 200 ms; and 4) to CW at 80 mW/cm2. Carbon-loaded Teflon electrodes were used to record the EKG from forelimbs of an animal before, during, and after irradiation whilst it was maintained in a constant exposure geometry in a wooden squeeze box. Field induced changes in the heart-beat rate were observed at 80 mW/cm2 but not a lower average power densities, although a peak positive chronotropic effect might have been occasioned by PM introduced at 100 and 200 ms after the R wave peak. No cumulative effect was observed over a period of four months. Thermographic analysis revealed relatively little absorption of microwave energy by the myocardium irrespective of anatomical aspect of exposure.",
  "effect": "mixed",
  "evidence": "very_low",
  "extraction": {
    "studyType": "animal",
    "studyTypeLabel": "Animal study",
    "effectDirection": "mixed",
    "evidenceLabel": "Very low",
    "population": "Adult New Zealand rabbits (2 male, 1 female albinos)",
    "sampleSize": "3",
    "exposure": "microwave · 2450 MHz · 20 min",
    "confidencePct": "74",
    "peerReviewed": "yes",
    "mainFindings": "Field-induced changes in heart-beat rate were observed at 80 mW/cm2 continuous-wave exposure but not at lower average power densities (5 mW/cm2). The authors note a possible peak positive chronotropic effect with pulsed microwaves triggered 100 and 200 ms after the R wave. No cumulative effect was observed over four months, and thermography suggested relatively little myocardial absorption regardless of exposure aspect.",
    "outcomes": [
      "heart-beat rate",
      "electrocardiogram (EKG)",
      "myocardial microwave energy absorption (thermographic analysis)"
    ],
    "limitations": [
      "Very small sample size (n=3)",
      "Animal study",
      "generalizability to humans unclear",
      "Some findings described as possible (uncertain) rather than definitive"
    ],
    "keywords": [
      "rabbit",
      "microwave radiation",
      "2450 MHz",
      "continuous wave",
      "pulsed wave",
      "power density",
      "heart rate",
      "chronotropic effect",
      "electrocardiogram",
      "thermography"
    ],
    "hubs": [],
    "raw": "{\n  \"study_type\": \"animal\",\n  \"exposure\": {\n    \"band\": \"microwave\",\n    \"source\": null,\n    \"frequency_mhz\": 2450,\n    \"sar_wkg\": null,\n    \"duration\": \"20 min\"\n  },\n  \"population\": \"Adult New Zealand rabbits (2 male, 1 female albinos)\",\n  \"sample_size\": 3,\n  \"outcomes\": [\n    \"heart-beat rate\",\n    \"electrocardiogram (EKG)\",\n    \"myocardial microwave energy absorption (thermographic analysis)\"\n  ],\n  \"main_findings\": \"Field-induced changes in heart-beat rate were observed at 80 mW/cm2 continuous-wave exposure but not at lower average power densities (5 mW/cm2). The authors note a possible peak positive chronotropic effect with pulsed microwaves triggered 100 and 200 ms after the R wave. No cumulative effect was observed over four months, and thermography suggested relatively little myocardial absorption regardless of exposure aspect.\",\n  \"effect_direction\": \"mixed\",\n  \"limitations\": [\n    \"Very small sample size (n=3)\",\n    \"Animal study; generalizability to humans unclear\",\n    \"Some findings described as possible (uncertain) rather than definitive\"\n  ],\n  \"evidence_strength\": \"very_low\",\n  \"confidence\": 0.74,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"rabbit\",\n    \"microwave radiation\",\n    \"2450 MHz\",\n    \"continuous wave\",\n    \"pulsed wave\",\n    \"power density\",\n    \"heart rate\",\n    \"chronotropic effect\",\n    \"electrocardiogram\",\n    \"thermography\"\n  ],\n  \"suggested_hubs\": []\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/6904510/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=6046",
  "updated": "2026-02-16 00:08:56"
}