  "title": "Erythrocyte hemolysis by radiofrequency fields.",
  "authors": [
    "S F Cleary",
    "L M Liu",
    "F Garber"
  ],
  "journal": "Bioelectromagnetics",
  "year": "1985",
  "doi": "10.1002/bem.2250060311",
  "pmid": "3836674",
  "abstract": "A field-strength-dependent hemolytic effect of continuous-wave radiofrequency (RF) exposure in vitro has been demonstrated. Erythrocytes in whole heparinized rabbit blood were hemolyzed by a 2-h exposure to 50- or 100-MHz RF fields at field strengths of greater than 4 V/cm. An effect of comparable magnitude resulted from exposure to 10-MHz RF at a field strength of 9 V/cm. Sample temperatures were maintained at 22.5 degrees +/- 0.2 degrees C. There was no apparent involvement of heating or temperature gradients, nor were there any RF exposure effects on cellular K+ or Na+ concentration, nor on pH. The mechanism of the hemolytic effect is not known. Since the percentage of lysed erythrocytes was less than 1% and there was an absence of effects on cellular cation concentrations, RF radiation may have irreversibly altered the plasma membrane permeability of a sensitive subpopulation of red cells (possibly aged cells) leading to osmotic lysis. RF radiation at these frequencies appears to affect red cells in a manner that is qualitatively and quantitatively different from microwave radiation.",
  "effect": "harm",
  "evidence": "low",
  "extraction": {
    "studyType": "in_vitro",
    "studyTypeLabel": "In vitro study",
    "effectDirection": "harm",
    "evidenceLabel": "Low",
    "population": "Erythrocytes in whole heparinized rabbit blood (in vitro)",
    "sampleSize": "—",
    "exposure": "RF · 2 h continuous-wave exposure",
    "confidencePct": "74",
    "peerReviewed": "yes",
    "mainFindings": "In vitro, erythrocytes in whole heparinized rabbit blood showed a field-strength-dependent hemolytic effect after 2 h continuous-wave RF exposure. Hemolysis occurred at 50 or 100 MHz at field strengths >4 V/cm, and at 10 MHz at 9 V/cm, with sample temperature maintained at 22.5 ± 0.2 °C and no apparent involvement of heating; no RF effects were observed on cellular K+ or Na+ concentrations or on pH.",
    "outcomes": [
      "Erythrocyte hemolysis (percent lysed cells)",
      "Cellular K+ concentration",
      "Cellular Na+ concentration",
      "pH",
      "Sample temperature/heating involvement"
    ],
    "limitations": [
      "In vitro study in rabbit blood",
      "generalizability to in vivo or humans not established in abstract",
      "Sample size not reported in abstract",
      "Hemolysis magnitude was <1% of erythrocytes",
      "Mechanism not known"
    ],
    "keywords": [
      "radiofrequency",
      "RF",
      "continuous-wave",
      "in vitro",
      "rabbit blood",
      "erythrocytes",
      "hemolysis",
      "field strength",
      "10 MHz",
      "50 MHz",
      "100 MHz",
      "membrane permeability",
      "non-thermal"
    ],
    "hubs": [],
    "raw": "{\n  \"study_type\": \"in_vitro\",\n  \"exposure\": {\n    \"band\": \"RF\",\n    \"source\": null,\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": \"2 h continuous-wave exposure\"\n  },\n  \"population\": \"Erythrocytes in whole heparinized rabbit blood (in vitro)\",\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"Erythrocyte hemolysis (percent lysed cells)\",\n    \"Cellular K+ concentration\",\n    \"Cellular Na+ concentration\",\n    \"pH\",\n    \"Sample temperature/heating involvement\"\n  ],\n  \"main_findings\": \"In vitro, erythrocytes in whole heparinized rabbit blood showed a field-strength-dependent hemolytic effect after 2 h continuous-wave RF exposure. Hemolysis occurred at 50 or 100 MHz at field strengths >4 V/cm, and at 10 MHz at 9 V/cm, with sample temperature maintained at 22.5 ± 0.2 °C and no apparent involvement of heating; no RF effects were observed on cellular K+ or Na+ concentrations or on pH.\",\n  \"effect_direction\": \"harm\",\n  \"limitations\": [\n    \"In vitro study in rabbit blood; generalizability to in vivo or humans not established in abstract\",\n    \"Sample size not reported in abstract\",\n    \"Hemolysis magnitude was <1% of erythrocytes\",\n    \"Mechanism not known\"\n  ],\n  \"evidence_strength\": \"low\",\n  \"confidence\": 0.74,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"radiofrequency\",\n    \"RF\",\n    \"continuous-wave\",\n    \"in vitro\",\n    \"rabbit blood\",\n    \"erythrocytes\",\n    \"hemolysis\",\n    \"field strength\",\n    \"10 MHz\",\n    \"50 MHz\",\n    \"100 MHz\",\n    \"membrane permeability\",\n    \"non-thermal\"\n  ],\n  \"suggested_hubs\": []\n}"
  },