  "id": 6192,
  "url": "https://nnemf.org/research/6192-effect-of-pulse-electromagnetic-radiation-on-erythrocyte-ghosts",
  "title": "[Effect of pulse electromagnetic radiation on erythrocyte ghosts].",
  "authors": [
    "Iu A Kim",
    "I K Kasimbekov",
    "B S Fomenko",
    "R E Tigranian"
  ],
  "journal": "Nauchnye doklady vysshei shkoly. Biologicheskie nauki",
  "year": "1986",
  "doi": null,
  "pmid": "3814660",
  "abstract": "The pulse microwave radiation has been shown to increase the fluorescence intensity of 2-toluidinonaphthanene-6-sulfonate (2,6-TNS) and 1-anilinonaphthalene-8-sulfonate (1,8-ANS) built-in membranes of erythrocyte ghosts. In experiments with 2,6-TNS a frequency dependence of the effect of microwave radiation with maximum within the frequency range of 55-65 Hz has been found. It is suggested that the changes registered with fluorescent probes are induced by mechanical oscillations generated by the pulse microwave radiation.",
  "effect": "harm",
  "evidence": "very_low",
  "extraction": {
    "studyType": "in_vitro",
    "studyTypeLabel": "In vitro study",
    "effectDirection": "harm",
    "evidenceLabel": "Very low",
    "population": "erythrocyte ghosts (membranes)",
    "sampleSize": "—",
    "exposure": "microwave",
    "confidencePct": "62",
    "peerReviewed": "yes",
    "mainFindings": "Pulse microwave radiation increased fluorescence intensity of 2,6-TNS and 1,8-ANS incorporated into erythrocyte ghost membranes. With 2,6-TNS, the effect showed frequency dependence with a maximum reported at 55–65 Hz.",
    "outcomes": [
      "Fluorescence intensity of 2-toluidinonaphthanene-6-sulfonate (2",
      "6-TNS) in erythrocyte ghost membranes",
      "Fluorescence intensity of 1-anilinonaphthalene-8-sulfonate (1",
      "8-ANS) in erythrocyte ghost membranes",
      "Frequency dependence of fluorescence changes (reported maximum at 55–65 Hz)"
    ],
    "limitations": [
      "No exposure metrics reported (e.g.",
      "power density",
      "SAR",
      "field strength).",
      "Sample size and experimental details not provided in the abstract.",
      "Frequency units/context unclear given microwave exposure described alongside a 55–65 Hz maximum."
    ],
    "keywords": [
      "pulse microwave radiation",
      "erythrocyte ghosts",
      "membrane",
      "fluorescent probes",
      "2",
      "6-TNS",
      "1",
      "8-ANS",
      "frequency dependence"
    ],
    "hubs": [],
    "raw": "{\n  \"study_type\": \"in_vitro\",\n  \"exposure\": {\n    \"band\": \"microwave\",\n    \"source\": null,\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": null\n  },\n  \"population\": \"erythrocyte ghosts (membranes)\",\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"Fluorescence intensity of 2-toluidinonaphthanene-6-sulfonate (2,6-TNS) in erythrocyte ghost membranes\",\n    \"Fluorescence intensity of 1-anilinonaphthalene-8-sulfonate (1,8-ANS) in erythrocyte ghost membranes\",\n    \"Frequency dependence of fluorescence changes (reported maximum at 55–65 Hz)\"\n  ],\n  \"main_findings\": \"Pulse microwave radiation increased fluorescence intensity of 2,6-TNS and 1,8-ANS incorporated into erythrocyte ghost membranes. With 2,6-TNS, the effect showed frequency dependence with a maximum reported at 55–65 Hz.\",\n  \"effect_direction\": \"harm\",\n  \"limitations\": [\n    \"No exposure metrics reported (e.g., power density, SAR, field strength).\",\n    \"Sample size and experimental details not provided in the abstract.\",\n    \"Frequency units/context unclear given microwave exposure described alongside a 55–65 Hz maximum.\"\n  ],\n  \"evidence_strength\": \"very_low\",\n  \"confidence\": 0.62,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"pulse microwave radiation\",\n    \"erythrocyte ghosts\",\n    \"membrane\",\n    \"fluorescent probes\",\n    \"2,6-TNS\",\n    \"1,8-ANS\",\n    \"frequency dependence\"\n  ],\n  \"suggested_hubs\": []\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/3814660/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=6192",
  "updated": "2026-02-16 01:22:21"
}