Share

Behavioral thermoregulation with microwave radiation of albino rats.

W F Vitulli, J M Mott, J M Quinn, K L Los Kamp, R S Dodson

PAPERpubmedPerceptual and motor skills1986Animal studyEffect: mixedEvidence: Low

Abstract

The objective of this exploratory study was to investigate the extent to which microwave radiation would reinforce operant behavior in a cold environment. A reversal-design with the single subject serving as its own control was used for testing the reinforcing properties of microwaves. Six albino rats were conditioned to produce 6-sec. pulses of microwave radiation within a refrigerated environment. The schedule of reinforcement was continuous (crf). Each lever press produced a 6-sec. output of microwave radiation. The intensity of radiation was varied across blocks of sessions in the reversal design. Microwave values used were as follows: 62.5 W, 125 W, 250 W, and 437.5 W. Sessions lasted from 8 to 9 hr. over an approximate 7-mo. period. Results showed that rates of operant responding varied as a direct function of microwave intensity. Relatively high mean rates were associated with moderate microwave intensity (250 W), whereas lower mean rates of responding were associated with extreme microwave intensities (62.5 W and 437.5 W) in the reversal design. These data are explained in terms of satiation and deprivation of the reinforcing value of microwave radiation.

AI evidence extraction

At a glance
Study type
Animal study
Effect direction
mixed
Population
Six albino rats
Sample size
6
Exposure
microwave · 6-sec pulses contingent on lever press; sessions 8–9 hr over ~7 months
Evidence strength
Low
Confidence: 74% · Peer-reviewed: yes

Main findings

In a refrigerated environment, rats were conditioned to lever-press to produce 6-second microwave pulses. Operant response rates varied directly with microwave intensity, with higher mean responding at a moderate intensity (250 W) and lower responding at the lowest (62.5 W) and highest (437.5 W) intensities tested.

Outcomes measured

  • Operant responding rate (lever pressing) as reinforcement/behavioral thermoregulation in a cold environment

Limitations

  • Exploratory study
  • Small sample size (n=6)
  • Single-subject reversal design
  • generalizability unclear
  • Microwave frequency and dosimetry (e.g.
  • SAR) not reported in abstract
View raw extracted JSON
{
  "study_type": "animal",
  "exposure": {
    "band": "microwave",
    "source": null,
    "frequency_mhz": null,
    "sar_wkg": null,
    "duration": "6-sec pulses contingent on lever press; sessions 8–9 hr over ~7 months"
  },
  "population": "Six albino rats",
  "sample_size": 6,
  "outcomes": [
    "Operant responding rate (lever pressing) as reinforcement/behavioral thermoregulation in a cold environment"
  ],
  "main_findings": "In a refrigerated environment, rats were conditioned to lever-press to produce 6-second microwave pulses. Operant response rates varied directly with microwave intensity, with higher mean responding at a moderate intensity (250 W) and lower responding at the lowest (62.5 W) and highest (437.5 W) intensities tested.",
  "effect_direction": "mixed",
  "limitations": [
    "Exploratory study",
    "Small sample size (n=6)",
    "Single-subject reversal design; generalizability unclear",
    "Microwave frequency and dosimetry (e.g., SAR) not reported in abstract"
  ],
  "evidence_strength": "low",
  "confidence": 0.74,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "microwave radiation",
    "albino rats",
    "operant conditioning",
    "reinforcement",
    "behavioral thermoregulation",
    "cold environment",
    "reversal design",
    "intensity (W)"
  ],
  "suggested_hubs": []
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.

NNEMF synthesis

Synthesis pending.

Original record: rfsafe.org paper 6199

Behavioral thermoregulation with microwave radiation of albino rats. · Non-native EMF