EMF biological effects
Share

Scattering of linearly polarized microwave radiation from a dielectric helix.

R D Haracz, L D Cohen, A Cohen, R T Wang

PAPERpubmedApplied optics1987engineeringEffect: unclearEvidence: Insufficient

Abstract

A method for calculating the electric field scattered from a helical dielectric target is compared to an equivalent experiment. The wavelength of the incident light is 3.18 cm, and the right-handed helix has a radius of 1.83 cm and wire radius of 0.24 cm, a pitch of 0.553 cm, and seven turns. The index of refraction of, the target is 1.626-i 0.012. A brief description of the Shifrin theory generalized to this application is given along with a discussion of the experiment, and the experimental intensities are compared to the first-order theory.

AI evidence extraction

At a glance
Study type
engineering
Effect direction
unclear
Population
—
Sample size
—
Exposure
microwave
Evidence strength
Insufficient
Confidence: 74% · Peer-reviewed: yes

Main findings

A calculation method for the electric field scattered from a helical dielectric target was compared with an equivalent experiment at a 3.18 cm incident wavelength, and experimental intensities were compared to first-order theory.

Outcomes measured

  • scattered electric field
  • experimental scattering intensities vs first-order theory

Limitations

  • No biological/health outcomes reported (engineering/optics scattering study).
  • Frequency not explicitly stated (only wavelength provided).
  • No quantitative agreement metrics between theory and experiment stated in the abstract.
View raw extracted JSON
{
  "study_type": "engineering",
  "exposure": {
    "band": "microwave",
    "source": "other",
    "frequency_mhz": null,
    "sar_wkg": null,
    "duration": null
  },
  "population": null,
  "sample_size": null,
  "outcomes": [
    "scattered electric field",
    "experimental scattering intensities vs first-order theory"
  ],
  "main_findings": "A calculation method for the electric field scattered from a helical dielectric target was compared with an equivalent experiment at a 3.18 cm incident wavelength, and experimental intensities were compared to first-order theory.",
  "effect_direction": "unclear",
  "limitations": [
    "No biological/health outcomes reported (engineering/optics scattering study).",
    "Frequency not explicitly stated (only wavelength provided).",
    "No quantitative agreement metrics between theory and experiment stated in the abstract."
  ],
  "evidence_strength": "insufficient",
  "confidence": 0.74,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "microwave radiation",
    "scattering",
    "dielectric helix",
    "linearly polarized",
    "Shifrin theory",
    "experimental validation"
  ],
  "suggested_hubs": []
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.

NNEMF synthesis

Synthesis pending.

Original record: rfsafe.org paper 6221

Scattering of linearly polarized microwave radiation from a dielectric helix. · Non-native EMF