  "id": 631,
  "url": "https://nnemf.org/research/631-in-vivo-genotoxicity-of-high-intensity-intermediate-frequency",
  "title": "In vivo genotoxicity of high-intensity intermediate frequency magnetic fields in somatic cells and germ cells",
  "authors": [],
  "journal": "Journal of radiation research",
  "year": "2022",
  "doi": "10.1093/jrr/rrac081",
  "pmid": "36579461",
  "abstract": "In vivo genotoxicity of high-intensity intermediate frequency magnetic fields in somatic cells and germ cells Ohtani S, Ushiyama A, Wada K, Suzuki Y, Hattori K. In vivo genotoxicity of high-intensity intermediate frequency magnetic fields in somatic cells and germ cells. J Radiat Res. 2022 Dec 29:rrac081. doi: 10.1093/jrr/rrac081. Abstract Intermediate frequency magnetic fields (IF-MFs) at ~85 kHz are one of the components of wireless power transfer (WPT) systems. However, the available data needed for the assessment of the safety of organisms from IF-MF exposure are scarce. Thus, there is an imminent need to accumulate evidence-based assessment data. In particular, if humans are exposed to IF-MF due to an accident or trouble, they are at increased risk of being exposed to high-intensity IF-MF within a short period. The already existing exposure system was improved to a system that could intermittently expose animals at 3 s intervals. This system allows the exposure of a mouse to high-intensity IF-MF (frequency: 82.3 kHz; induced electric field: 87 V/m, which was 3.8 times the basic restriction level for occupational exposure in the ICNIRP guideline), while regulating the heat generated by the coil. In vivo genotoxicity after IF-MF exposure was assessed using micronucleus (MN) test, Pig-a assay, and gpt assay. The results of MN test and Pig-a assay in hematopoietic cells revealed that neither the reticulocytes nor the mature erythrocytes exhibited significant increases in the IF-MF-exposed group compared with that in the sham-exposed group. In germ cells, MN test and gpt assay outcomes showed that IF-MF exposure did not cause any genetic or chromosomal abnormality. Based on these data, there was no genotoxic effect of our set IF-MF exposure on somatic and germ cells. These findings can contribute to the widespread use of WPT systems as effective data of IF-MF safety assessment. https://pubmed.ncbi.nlm.nih.gov/36579461/",
  "effect": "no_effect",
  "evidence": "low",
  "extraction": {
    "studyType": "animal",
    "studyTypeLabel": "Animal study",
    "effectDirection": "no_effect",
    "evidenceLabel": "Low",
    "population": "Mouse",
    "sampleSize": "—",
    "exposure": "intermediate frequency wireless power transfer (WPT) systems · 0.0823 MHz · intermittent exposure at 3 s intervals",
    "confidencePct": "78",
    "peerReviewed": "yes",
    "mainFindings": "In hematopoietic cells, micronucleus and Pig-a assay results showed no significant increases in reticulocytes or mature erythrocytes in IF-MF-exposed mice versus sham. In germ cells, micronucleus and gpt assay outcomes indicated no genetic or chromosomal abnormalities; overall, no genotoxic effect was observed under the described IF-MF exposure conditions.",
    "outcomes": [
      "Genotoxicity in hematopoietic cells (micronucleus test)",
      "Mutagenicity in hematopoietic cells (Pig-a assay)",
      "Genotoxicity/mutagenicity in germ cells (micronucleus test",
      "gpt assay)"
    ],
    "limitations": [
      "Sample size not reported in abstract",
      "Exposure duration/total exposure time not specified in abstract",
      "Only genotoxicity endpoints assessed (MN",
      "Pig-a",
      "gpt)",
      "other health outcomes not addressed"
    ],
    "keywords": [
      "intermediate frequency magnetic fields",
      "IF-MF",
      "wireless power transfer",
      "WPT",
      "82.3 kHz",
      "induced electric field",
      "ICNIRP",
      "occupational exposure",
      "micronucleus test",
      "Pig-a assay",
      "gpt assay",
      "genotoxicity",
      "germ cells",
      "somatic cells",
      "mouse"
    ],
    "hubs": [
      {
        "slug": "who-icnirp",
        "weight": "0.7",
        "reason": "Exposure level is explicitly compared to the ICNIRP basic restriction level for occupational exposure."
      }
    ],
    "raw": "{\n  \"study_type\": \"animal\",\n  \"exposure\": {\n    \"band\": \"intermediate frequency\",\n    \"source\": \"wireless power transfer (WPT) systems\",\n    \"frequency_mhz\": 0.0823,\n    \"sar_wkg\": null,\n    \"duration\": \"intermittent exposure at 3 s intervals\"\n  },\n  \"population\": \"Mouse\",\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"Genotoxicity in hematopoietic cells (micronucleus test)\",\n    \"Mutagenicity in hematopoietic cells (Pig-a assay)\",\n    \"Genotoxicity/mutagenicity in germ cells (micronucleus test, gpt assay)\"\n  ],\n  \"main_findings\": \"In hematopoietic cells, micronucleus and Pig-a assay results showed no significant increases in reticulocytes or mature erythrocytes in IF-MF-exposed mice versus sham. In germ cells, micronucleus and gpt assay outcomes indicated no genetic or chromosomal abnormalities; overall, no genotoxic effect was observed under the described IF-MF exposure conditions.\",\n  \"effect_direction\": \"no_effect\",\n  \"limitations\": [\n    \"Sample size not reported in abstract\",\n    \"Exposure duration/total exposure time not specified in abstract\",\n    \"Only genotoxicity endpoints assessed (MN, Pig-a, gpt); other health outcomes not addressed\"\n  ],\n  \"evidence_strength\": \"low\",\n  \"confidence\": 0.78,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"intermediate frequency magnetic fields\",\n    \"IF-MF\",\n    \"wireless power transfer\",\n    \"WPT\",\n    \"82.3 kHz\",\n    \"induced electric field\",\n    \"ICNIRP\",\n    \"occupational exposure\",\n    \"micronucleus test\",\n    \"Pig-a assay\",\n    \"gpt assay\",\n    \"genotoxicity\",\n    \"germ cells\",\n    \"somatic cells\",\n    \"mouse\"\n  ],\n  \"suggested_hubs\": [\n    {\n      \"slug\": \"who-icnirp\",\n      \"weight\": 0.6,\n      \"reason\": \"Exposure level is explicitly compared to the ICNIRP basic restriction level for occupational exposure.\"\n    }\n  ]\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/36579461/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=631",
  "updated": "2026-02-10 10:44:45"
}