  "id": 6331,
  "url": "https://nnemf.org/research/6331-effects-of-2375-mhz-pulse-modulated-microwave-radiation",
  "title": "[Effects of 2375 MHz pulse-modulated microwave radiation on ATPase activity of the rat muscle actomyosin].",
  "authors": [
    "M S Pashovskina",
    "I G Akoev"
  ],
  "journal": "Radiatsionnaia biologiia, radioecologiia",
  "year": "1996",
  "doi": null,
  "pmid": "9019280",
  "abstract": "Solution of rat muscle actomyosin (AM) was exposed to pulse-modulated microwave. Carried frequency was 2375 MHz. The rectangular pulse modulation was in the range of 50-300 pulses per second. It was shown that AM activity was dependent both on modulation frequency as well as on microwave intensity. It was shown the frequencies of modulation which were changed ATP-ase activity of AM.",
  "effect": "mixed",
  "evidence": "very_low",
  "extraction": {
    "studyType": "in_vitro",
    "studyTypeLabel": "In vitro study",
    "effectDirection": "mixed",
    "evidenceLabel": "Very low",
    "population": "—",
    "sampleSize": "—",
    "exposure": "microwave · 2375 MHz",
    "confidencePct": "66",
    "peerReviewed": "yes",
    "mainFindings": "Rat muscle actomyosin solution exposed to 2375 MHz pulse-modulated microwave radiation showed ATPase activity changes that depended on modulation frequency (50–300 pulses/second) and microwave intensity; specific modulation frequencies were reported to change ATPase activity.",
    "outcomes": [
      "ATPase activity of rat muscle actomyosin"
    ],
    "limitations": [
      "No sample size reported in abstract.",
      "No exposure duration reported in abstract.",
      "No quantitative effect sizes or statistical details reported in abstract.",
      "Exposure intensity metric not specified in abstract (e.g.",
      "power density/SAR)."
    ],
    "keywords": [
      "2375 MHz",
      "pulse-modulated microwave",
      "rectangular pulse modulation",
      "actomyosin",
      "ATPase activity",
      "rat muscle",
      "in vitro"
    ],
    "hubs": [],
    "raw": "{\n  \"study_type\": \"in_vitro\",\n  \"exposure\": {\n    \"band\": \"microwave\",\n    \"source\": null,\n    \"frequency_mhz\": 2375,\n    \"sar_wkg\": null,\n    \"duration\": null\n  },\n  \"population\": null,\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"ATPase activity of rat muscle actomyosin\"\n  ],\n  \"main_findings\": \"Rat muscle actomyosin solution exposed to 2375 MHz pulse-modulated microwave radiation showed ATPase activity changes that depended on modulation frequency (50–300 pulses/second) and microwave intensity; specific modulation frequencies were reported to change ATPase activity.\",\n  \"effect_direction\": \"mixed\",\n  \"limitations\": [\n    \"No sample size reported in abstract.\",\n    \"No exposure duration reported in abstract.\",\n    \"No quantitative effect sizes or statistical details reported in abstract.\",\n    \"Exposure intensity metric not specified in abstract (e.g., power density/SAR).\"\n  ],\n  \"evidence_strength\": \"very_low\",\n  \"confidence\": 0.66,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"2375 MHz\",\n    \"pulse-modulated microwave\",\n    \"rectangular pulse modulation\",\n    \"actomyosin\",\n    \"ATPase activity\",\n    \"rat muscle\",\n    \"in vitro\"\n  ],\n  \"suggested_hubs\": []\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/9019280/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=6331",
  "updated": "2026-02-16 01:38:08"
}