{
  "id": 6372,
  "url": "https://nnemf.org/research/6372-changes-in-serum-alkaline-phosphatase-activity-during-in",
  "title": "[Changes in serum alkaline phosphatase activity during in vitro exposure to amplitude-modulated electromagnetic field of ultrahigh frequency (2375 MHz) in guinea pigs].",
  "authors": [
    "M S Pashovkina",
    "I G Akoev"
  ],
  "journal": "Biofizika",
  "year": "2000",
  "doi": null,
  "pmid": "10732222",
  "abstract": "The activity of alkaline phosphatase by the action of pulse-modulated microwave radiation was studied. The carrier frequency of radiation was 2375 MHz, the range of modulation pulse rate was 10-390 Hz with the on-off time ratio 2, and the specific absorption rate was 8 and 0.8 microW/cm2. Time of exposure was 1 and 3 min under conditions of continuous temperature control. It was shown that the activity of alkaline phosphatase depends on both modulation frequency and intensity of superhigh-frequency electromagnetic radiation. At a frequency of 70 Hz, the activity of alkaline phosphatases increased 1.8-2.0 times.",
  "effect": "harm",
  "evidence": "low",
  "extraction": {
    "studyType": "animal",
    "studyTypeLabel": "Animal study",
    "effectDirection": "harm",
    "evidenceLabel": "Low",
    "population": "guinea pigs (in vitro serum)",
    "sampleSize": "—",
    "exposure": "RF · 2375 MHz · 1 and 3 min",
    "confidencePct": "74",
    "peerReviewed": "yes",
    "mainFindings": "In vitro exposure to pulse-modulated microwave radiation (carrier 2375 MHz; modulation pulse rate 10–390 Hz) altered alkaline phosphatase activity depending on modulation frequency and intensity. At 70 Hz modulation, alkaline phosphatase activity increased by about 1.8–2.0 times.",
    "outcomes": [
      "serum alkaline phosphatase activity"
    ],
    "limitations": [
      "In vitro study (serum enzyme activity) rather than whole-animal health outcomes",
      "Sample size not reported in abstract",
      "Exposure metric reported as microW/cm2",
      "SAR in W/kg not provided",
      "Short exposure durations (1 and 3 minutes)"
    ],
    "keywords": [
      "2375 MHz",
      "microwave",
      "RF",
      "pulse-modulated",
      "amplitude-modulated",
      "modulation frequency",
      "guinea pig",
      "in vitro",
      "alkaline phosphatase",
      "enzyme activity"
    ],
    "hubs": [],
    "raw": "{\n  \"study_type\": \"animal\",\n  \"exposure\": {\n    \"band\": \"RF\",\n    \"source\": null,\n    \"frequency_mhz\": 2375,\n    \"sar_wkg\": null,\n    \"duration\": \"1 and 3 min\"\n  },\n  \"population\": \"guinea pigs (in vitro serum)\",\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"serum alkaline phosphatase activity\"\n  ],\n  \"main_findings\": \"In vitro exposure to pulse-modulated microwave radiation (carrier 2375 MHz; modulation pulse rate 10–390 Hz) altered alkaline phosphatase activity depending on modulation frequency and intensity. At 70 Hz modulation, alkaline phosphatase activity increased by about 1.8–2.0 times.\",\n  \"effect_direction\": \"harm\",\n  \"limitations\": [\n    \"In vitro study (serum enzyme activity) rather than whole-animal health outcomes\",\n    \"Sample size not reported in abstract\",\n    \"Exposure metric reported as microW/cm2; SAR in W/kg not provided\",\n    \"Short exposure durations (1 and 3 minutes)\"\n  ],\n  \"evidence_strength\": \"low\",\n  \"confidence\": 0.74,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"2375 MHz\",\n    \"microwave\",\n    \"RF\",\n    \"pulse-modulated\",\n    \"amplitude-modulated\",\n    \"modulation frequency\",\n    \"guinea pig\",\n    \"in vitro\",\n    \"alkaline phosphatase\",\n    \"enzyme activity\"\n  ],\n  \"suggested_hubs\": []\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/10732222/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=6372",
  "updated": "2026-02-16 01:43:04"
}