{
  "id": 6421,
  "url": "https://nnemf.org/research/6421-spectroscopy-and-microscopy-of-spin-sensitive-rectification-current",
  "title": "Spectroscopy and microscopy of spin-sensitive rectification current induced by microwave radiation.",
  "authors": [
    "Joonhee Lee",
    "Xiuwen Tu",
    "Wilson Ho"
  ],
  "journal": "Nano letters",
  "year": "2005",
  "doi": "10.1021/nl0522330",
  "pmid": "16351224",
  "abstract": "Amplitude-modulated microwave radiation was applied to the junction of a scanning tunneling microscope (STM). Rectification in the tunneling current was induced by the microwave because of the nonlinearity of the junction. It is shown that this rectification current is proportional to the d(2)I/dV(2) signal and exhibits spin-sensitivity. The magnetic domain at the apex of an iron-coated tip was manipulated by applying an external magnetic field. The moment of spin flip and the magnetic hysteresis were measured by changes in the spin-dependent current through the Cr(001) surface.",
  "effect": "unclear",
  "evidence": "insufficient",
  "extraction": {
    "studyType": "engineering",
    "studyTypeLabel": "engineering",
    "effectDirection": "unclear",
    "evidenceLabel": "Insufficient",
    "population": "—",
    "sampleSize": "—",
    "exposure": "microwave",
    "confidencePct": "74",
    "peerReviewed": "yes",
    "mainFindings": "Amplitude-modulated microwave radiation applied to an STM junction induced rectification in the tunneling current due to junction nonlinearity. The rectification current was proportional to the d^2I/dV^2 signal and exhibited spin sensitivity; spin flip and magnetic hysteresis were measured via changes in spin-dependent current through a Cr(001) surface.",
    "outcomes": [
      "Rectification current in STM tunneling junction",
      "Spin-sensitive signal (spin-dependent current)",
      "Magnetic hysteresis",
      "Spin flip moment"
    ],
    "limitations": [
      "No microwave frequency",
      "power",
      "or dosimetry parameters reported in the abstract",
      "No biological population or health outcomes (instrumentation/physics study)"
    ],
    "keywords": [
      "microwave radiation",
      "amplitude-modulated",
      "scanning tunneling microscope",
      "rectification",
      "tunneling current",
      "spin sensitivity",
      "magnetic hysteresis",
      "spin flip",
      "iron-coated tip",
      "Cr(001) surface"
    ],
    "hubs": [],
    "raw": "{\n  \"study_type\": \"engineering\",\n  \"exposure\": {\n    \"band\": \"microwave\",\n    \"source\": \"other\",\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": null\n  },\n  \"population\": null,\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"Rectification current in STM tunneling junction\",\n    \"Spin-sensitive signal (spin-dependent current)\",\n    \"Magnetic hysteresis\",\n    \"Spin flip moment\"\n  ],\n  \"main_findings\": \"Amplitude-modulated microwave radiation applied to an STM junction induced rectification in the tunneling current due to junction nonlinearity. The rectification current was proportional to the d^2I/dV^2 signal and exhibited spin sensitivity; spin flip and magnetic hysteresis were measured via changes in spin-dependent current through a Cr(001) surface.\",\n  \"effect_direction\": \"unclear\",\n  \"limitations\": [\n    \"No microwave frequency, power, or dosimetry parameters reported in the abstract\",\n    \"No biological population or health outcomes (instrumentation/physics study)\"\n  ],\n  \"evidence_strength\": \"insufficient\",\n  \"confidence\": 0.74,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"microwave radiation\",\n    \"amplitude-modulated\",\n    \"scanning tunneling microscope\",\n    \"rectification\",\n    \"tunneling current\",\n    \"spin sensitivity\",\n    \"magnetic hysteresis\",\n    \"spin flip\",\n    \"iron-coated tip\",\n    \"Cr(001) surface\"\n  ],\n  \"suggested_hubs\": []\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/16351224/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=6421",
  "updated": "2026-02-16 01:50:14"
}