{
  "id": 647,
  "url": "https://nnemf.org/research/647-comparison-of-personal-exposure-to-radiofrequency-electromagnetic-fields",
  "title": "Comparison of personal exposure to Radiofrequency Electromagnetic Fields from Wi-Fi in a Spanish university over three years",
  "authors": [],
  "journal": "The Science of the total environment",
  "year": "2022",
  "doi": "10.1016/j.scitotenv.2022.160008",
  "pmid": "36368387",
  "abstract": "Comparison of personal exposure to Radiofrequency Electromagnetic Fields from Wi-Fi in a Spanish university over three years Ramirez-Vazquez R, Escobar I, Martinez-Plaza A, Arribas E. Comparison of personal exposure to Radiofrequency Electromagnetic Fields from Wi-Fi in a Spanish university over three years [published online ahead of print, 2022 Nov 8]. Sci Total Environ. 2022;160008. doi:10.1016/j.scitotenv.2022.160008. Abstract In this work we present the personal exposure levels to Radiofrequency Electromagnetic Fields (RF-EMF) from Wireless Fidelity (Wi-Fi) 2.4 GHz and 5.85 GHz bands in a Spanish university, specifically, at the Faculty of Computer Science Engineering at the University of Castilla-La Mancha (Albacete, Spain). We present results from three years, 2017, 2018 and 2019 in the same study place and points; and measurements carried out in 2022 inside a classroom and inside a professor's office, with the aim to compare the measurements and verify compliance with reference levels established by the International Commission on Non-Ionizing Radiation Protection (ICNIRP). The minimum average was 0.0900 μW/m2 in the 2.4 GHz Wi-Fi, in 2019, and the maximum average was 211 μW/m2 in the 5.85 GHz Wi-Fi in 2017, around the building. Comparing the measurements carried out inside the classroom with students and without students, we identified that the maximum value was 278 μW/m2 (classroom with students, in the 5.85 GHz Wi-Fi band) and the minimum value was 37.9 μW/m2 (classroom without students, in the 5.85 GHz Wi-Fi band). Finally, comparing the results of all the measurements (average values) inside the classroom and inside a professor's office, the maximum value was 205 μW/m2 (in the 5.85 GHz Wi-Fi band) inside the classroom with students, and the minimum value was 0.217 μW/m2 inside a professor's office (in the 2.4 GHz Wi-Fi band). These values in no case exceed the limits established by the International Commission on Non-Ionizing Radiation Protection, 10 W/m2 for general public exposure. https://pubmed.ncbi.nlm.nih.gov/36368387/",
  "effect": "no_effect",
  "evidence": "low",
  "extraction": {
    "studyType": "exposure_assessment",
    "studyTypeLabel": "exposure assessment",
    "effectDirection": "no_effect",
    "evidenceLabel": "Low",
    "population": "—",
    "sampleSize": "—",
    "exposure": "RF wi-fi · Measurements reported for years 2017, 2018, 2019; additional measurements in 2022",
    "confidencePct": "78",
    "peerReviewed": "yes",
    "mainFindings": "Personal exposure to Wi‑Fi RF‑EMF (2.4 GHz and 5.85 GHz) was measured at a Spanish university across 2017–2019 and in 2022 (classroom and professor’s office). Reported average values ranged from 0.0900 µW/m² (2.4 GHz, 2019) to 211 µW/m² (5.85 GHz, 2017, around the building); classroom measurements ranged from 37.9 µW/m² (without students, 5.85 GHz) to 278 µW/m² (with students, 5.85 GHz). The authors report that none of the measured values exceeded the ICNIRP general public limit of 10 W/m².",
    "outcomes": [
      "Personal exposure levels to RF-EMF from Wi‑Fi (2.4 GHz and 5.85 GHz) expressed as power density (µW/m²)",
      "Compliance with ICNIRP general public reference level (10 W/m²)"
    ],
    "limitations": [],
    "keywords": [
      "RF-EMF",
      "Wi-Fi",
      "2.4 GHz",
      "5.85 GHz",
      "personal exposure",
      "power density",
      "university",
      "classroom",
      "ICNIRP compliance"
    ],
    "hubs": [
      {
        "slug": "school-wi-fi",
        "weight": "0.7",
        "reason": "Measures Wi‑Fi RF‑EMF exposure in classroom/university settings."
      },
      {
        "slug": "who-icnirp",
        "weight": "0.7",
        "reason": "Assesses compliance with ICNIRP reference levels."
      }
    ],
    "raw": "{\n  \"study_type\": \"exposure_assessment\",\n  \"exposure\": {\n    \"band\": \"RF\",\n    \"source\": \"wi-fi\",\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": \"Measurements reported for years 2017, 2018, 2019; additional measurements in 2022\"\n  },\n  \"population\": null,\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"Personal exposure levels to RF-EMF from Wi‑Fi (2.4 GHz and 5.85 GHz) expressed as power density (µW/m²)\",\n    \"Compliance with ICNIRP general public reference level (10 W/m²)\"\n  ],\n  \"main_findings\": \"Personal exposure to Wi‑Fi RF‑EMF (2.4 GHz and 5.85 GHz) was measured at a Spanish university across 2017–2019 and in 2022 (classroom and professor’s office). Reported average values ranged from 0.0900 µW/m² (2.4 GHz, 2019) to 211 µW/m² (5.85 GHz, 2017, around the building); classroom measurements ranged from 37.9 µW/m² (without students, 5.85 GHz) to 278 µW/m² (with students, 5.85 GHz). The authors report that none of the measured values exceeded the ICNIRP general public limit of 10 W/m².\",\n  \"effect_direction\": \"no_effect\",\n  \"limitations\": [],\n  \"evidence_strength\": \"low\",\n  \"confidence\": 0.78,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"RF-EMF\",\n    \"Wi-Fi\",\n    \"2.4 GHz\",\n    \"5.85 GHz\",\n    \"personal exposure\",\n    \"power density\",\n    \"university\",\n    \"classroom\",\n    \"ICNIRP compliance\"\n  ],\n  \"suggested_hubs\": [\n    {\n      \"slug\": \"school-wi-fi\",\n      \"weight\": 0.9,\n      \"reason\": \"Measures Wi‑Fi RF‑EMF exposure in classroom/university settings.\"\n    },\n    {\n      \"slug\": \"who-icnirp\",\n      \"weight\": 0.7,\n      \"reason\": \"Assesses compliance with ICNIRP reference levels.\"\n    }\n  ]\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/36368387/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=647",
  "updated": "2026-02-10 10:46:14"
}