{
  "id": 6598,
  "url": "https://nnemf.org/research/6598-overwhelming-thermomechanical-motion-with-microwave-radiation-pressure-shot",
  "title": "Overwhelming Thermomechanical Motion with Microwave Radiation Pressure Shot Noise.",
  "authors": [
    "J D Teufel",
    "F Lecocq",
    "R W Simmonds"
  ],
  "journal": "Physical review letters",
  "year": "2016",
  "doi": "10.1103/physrevlett.116.013602",
  "pmid": "26799018",
  "abstract": "We measure the fundamental noise processes associated with a continuous linear position measurement of a micromechanical membrane incorporated in a microwave cavity optomechanical circuit. We observe the trade-off between the two fundamental sources of noise that enforce the standard quantum limit: the measurement imprecision and radiation pressure backaction from photon shot noise. We demonstrate that the quantum backaction of the measurement can overwhelm the intrinsic thermal motion by 24 dB, entering a new regime for cavity optomechanical systems.",
  "effect": "unclear",
  "evidence": "insufficient",
  "extraction": {
    "studyType": "engineering",
    "studyTypeLabel": "engineering",
    "effectDirection": "unclear",
    "evidenceLabel": "Insufficient",
    "population": "—",
    "sampleSize": "—",
    "exposure": "microwave",
    "confidencePct": "74",
    "peerReviewed": "yes",
    "mainFindings": "In a microwave cavity optomechanical circuit measuring a micromechanical membrane position, the authors observed the trade-off between measurement imprecision and radiation-pressure backaction from photon shot noise. They report that quantum backaction can overwhelm intrinsic thermal motion by 24 dB.",
    "outcomes": [
      "measurement imprecision noise",
      "radiation pressure backaction (photon shot noise)",
      "thermomechanical (intrinsic thermal) motion",
      "standard quantum limit trade-off"
    ],
    "limitations": [],
    "keywords": [
      "microwave",
      "cavity optomechanics",
      "micromechanical membrane",
      "radiation pressure",
      "photon shot noise",
      "quantum backaction",
      "standard quantum limit",
      "thermomechanical motion",
      "position measurement",
      "noise processes"
    ],
    "hubs": [],
    "raw": "{\n  \"study_type\": \"engineering\",\n  \"exposure\": {\n    \"band\": \"microwave\",\n    \"source\": \"microwave cavity optomechanical circuit\",\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": null\n  },\n  \"population\": null,\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"measurement imprecision noise\",\n    \"radiation pressure backaction (photon shot noise)\",\n    \"thermomechanical (intrinsic thermal) motion\",\n    \"standard quantum limit trade-off\"\n  ],\n  \"main_findings\": \"In a microwave cavity optomechanical circuit measuring a micromechanical membrane position, the authors observed the trade-off between measurement imprecision and radiation-pressure backaction from photon shot noise. They report that quantum backaction can overwhelm intrinsic thermal motion by 24 dB.\",\n  \"effect_direction\": \"unclear\",\n  \"limitations\": [],\n  \"evidence_strength\": \"insufficient\",\n  \"confidence\": 0.74,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"microwave\",\n    \"cavity optomechanics\",\n    \"micromechanical membrane\",\n    \"radiation pressure\",\n    \"photon shot noise\",\n    \"quantum backaction\",\n    \"standard quantum limit\",\n    \"thermomechanical motion\",\n    \"position measurement\",\n    \"noise processes\"\n  ],\n  \"suggested_hubs\": []\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/26799018/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=6598",
  "updated": "2026-02-16 02:06:17"
}