  "id": 6617,
  "url": "https://nnemf.org/research/6617-demonstration-of-long-distance-hazard-free-wearable-eeg",
  "title": "Demonstration of long-distance hazard-free wearable EEG monitoring system using mobile phone visible light communication.",
  "authors": [
    "Vega Pradana Rachim",
    "Yubing Jiang",
    "Hyeon-Seok Lee",
    "Wan-Young Chung"
  ],
  "journal": "Optics express",
  "year": "2017",
  "doi": "10.1364/oe.25.000713",
  "pmid": "28157960",
  "abstract": "A wearable electroencephalogram (EEG) is a small mobile device used for long-term brain monitoring systems. Applications of these systems include fatigue monitoring, mental/emotional monitoring, and brain-computer interfaces. However, the usage of wireless wearable EEG systems is limited due to the risks posed by the wireless RF communication radiation in a long-term exposure to the human brain. A novel microwave radiation-free system was developed by integrating visible light communication technology into a wearable EEG device. In this work, we investigated the system's performance in transmitting EEG data at different illuminance level and proposed an algorithm that functions at low illuminance levels for increased transmission distance. Using a 30 Hz smartphone camera, the proposed system was able to transmit 2.4 kbps of error-free EEG data up to 4 meter, which is equal to ~300 lux using an aspheric focus lens.",
  "effect": "unclear",
  "evidence": "insufficient",
  "extraction": {
    "studyType": "engineering",
    "studyTypeLabel": "engineering",
    "effectDirection": "unclear",
    "evidenceLabel": "Insufficient",
    "population": "—",
    "sampleSize": "—",
    "exposure": "RF wireless wearable EEG RF communication · long-term exposure (mentioned as a concern)",
    "confidencePct": "74",
    "peerReviewed": "yes",
    "mainFindings": "The authors developed a microwave radiation-free wearable EEG system using visible light communication. Using a 30 Hz smartphone camera, the system transmitted 2.4 kbps of error-free EEG data up to 4 m (approximately 300 lux) with an aspheric focus lens, and an algorithm was proposed to function at low illuminance for increased distance.",
    "outcomes": [
      "EEG data transmission performance",
      "Data rate (kbps)",
      "Transmission distance (meters)",
      "Error-free transmission",
      "Illuminance level (lux)"
    ],
    "limitations": [
      "No human health outcomes were measured",
      "RF risk is discussed as motivation rather than tested.",
      "No RF exposure metrics (e.g.",
      "frequency",
      "power",
      "SAR) are reported.",
      "Sample size/participant details are not provided in the abstract."
    ],
    "keywords": [
      "wearable EEG",
      "visible light communication",
      "VLC",
      "microwave radiation-free",
      "RF communication",
      "smartphone camera",
      "illuminance",
      "data transmission"
    ],
    "hubs": [],
    "raw": "{\n  \"study_type\": \"engineering\",\n  \"exposure\": {\n    \"band\": \"RF\",\n    \"source\": \"wireless wearable EEG RF communication\",\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": \"long-term exposure (mentioned as a concern)\"\n  },\n  \"population\": null,\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"EEG data transmission performance\",\n    \"Data rate (kbps)\",\n    \"Transmission distance (meters)\",\n    \"Error-free transmission\",\n    \"Illuminance level (lux)\"\n  ],\n  \"main_findings\": \"The authors developed a microwave radiation-free wearable EEG system using visible light communication. Using a 30 Hz smartphone camera, the system transmitted 2.4 kbps of error-free EEG data up to 4 m (approximately 300 lux) with an aspheric focus lens, and an algorithm was proposed to function at low illuminance for increased distance.\",\n  \"effect_direction\": \"unclear\",\n  \"limitations\": [\n    \"No human health outcomes were measured; RF risk is discussed as motivation rather than tested.\",\n    \"No RF exposure metrics (e.g., frequency, power, SAR) are reported.\",\n    \"Sample size/participant details are not provided in the abstract.\"\n  ],\n  \"evidence_strength\": \"insufficient\",\n  \"confidence\": 0.74,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"wearable EEG\",\n    \"visible light communication\",\n    \"VLC\",\n    \"microwave radiation-free\",\n    \"RF communication\",\n    \"smartphone camera\",\n    \"illuminance\",\n    \"data transmission\"\n  ],\n  \"suggested_hubs\": []\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/28157960/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=6617",
  "updated": "2026-02-16 02:06:41"
}