A 50 Hz magnetic field influences the viability of breast cancer cells 96 h after exposure
Abstract
A 50 Hz magnetic field influences the viability of breast cancer cells 96 h after exposure
AI evidence extraction
At a glance
Study type
In vitro study
Effect direction
mixed
Population
Breast cell lines (MDA-MB-231, MCF-7, MCF-10A)
Sample size
—
Exposure
ELF · 0.00005 MHz · 4–8 h and 24 h (examined 96 h after beginning of exposure)
Evidence strength
Low
Confidence: 78% · Peer-reviewed: yes
Main findings
Breast cell lines exposed to 50 Hz ELF magnetic fields (0.1 mT or 1.0 mT) showed exposure-duration-dependent changes assessed 96 h after exposure began. Short-term exposure (4–8 h) increased viability in breast cancer cells, while longer high exposure (24 h at 1.0 mT) decreased viability and proliferation in all cell lines; mitochondrial membrane potential and ROS were altered.
Outcomes measured
- Cell viability
- Cell proliferation
- Mitochondrial membrane potential
- Reactive oxygen species (ROS) production
Limitations
- In vitro study (cell lines)
- not clinical outcomes
- Sample size not reported in abstract
- Exposure conditions limited to 0.1 mT and 1.0 mT at 50 Hz and up to 24 h
- Outcomes assessed at a single post-exposure timepoint (96 h after beginning of exposure)
Suggested hubs
- occupational-exposure (0.7)Abstract notes flux densities compatible with workplace exposure limits (ELF magnetic fields).
View raw extracted JSON
{
"study_type": "in_vitro",
"exposure": {
"band": "ELF",
"source": null,
"frequency_mhz": 0.00005,
"sar_wkg": null,
"duration": "4–8 h and 24 h (examined 96 h after beginning of exposure)"
},
"population": "Breast cell lines (MDA-MB-231, MCF-7, MCF-10A)",
"sample_size": null,
"outcomes": [
"Cell viability",
"Cell proliferation",
"Mitochondrial membrane potential",
"Reactive oxygen species (ROS) production"
],
"main_findings": "Breast cell lines exposed to 50 Hz ELF magnetic fields (0.1 mT or 1.0 mT) showed exposure-duration-dependent changes assessed 96 h after exposure began. Short-term exposure (4–8 h) increased viability in breast cancer cells, while longer high exposure (24 h at 1.0 mT) decreased viability and proliferation in all cell lines; mitochondrial membrane potential and ROS were altered.",
"effect_direction": "mixed",
"limitations": [
"In vitro study (cell lines), not clinical outcomes",
"Sample size not reported in abstract",
"Exposure conditions limited to 0.1 mT and 1.0 mT at 50 Hz and up to 24 h",
"Outcomes assessed at a single post-exposure timepoint (96 h after beginning of exposure)"
],
"evidence_strength": "low",
"confidence": 0.78,
"peer_reviewed_likely": "yes",
"keywords": [
"50 Hz",
"ELF-MF",
"magnetic field",
"0.1 mT",
"1.0 mT",
"breast cancer cells",
"MDA-MB-231",
"MCF-7",
"MCF-10A",
"viability",
"proliferation",
"mitochondria",
"ROS"
],
"suggested_hubs": [
{
"slug": "occupational-exposure",
"weight": 0.35,
"reason": "Abstract notes flux densities compatible with workplace exposure limits (ELF magnetic fields)."
}
]
}AI can be wrong. Always verify against the paper.
AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.
Comments
Log in to comment.
No comments yet.
NNEMF synthesis
Synthesis pending.