  "id": 6670,
  "url": "https://nnemf.org/research/6670-antibody-responses-of-mice-exposed-to-low-power",
  "title": "Antibody responses of mice exposed to low-power microwaves under combined, pulse-and-amplitude modulation",
  "authors": [
    "B Veyret",
    "C Bouthet",
    "P Deschaux",
    "R de Seze",
    "M Geffard",
    "J Joussot-Dubien",
    "M le Diraison",
    "J M Moreau",
    "A Caristan"
  ],
  "journal": "Bioelectromagnetics",
  "year": "1991",
  "doi": "10.1002/bem.2250120107",
  "pmid": "2012621",
  "abstract": "Irradiation by pulsed microwaves (9.4 GHz, 1 microsecond pulses at 1,000/s), both with and without concurrent amplitude modulation (AM) by a sinusoid at discrete frequencies between 14 and 41 MHz, was assessed for effects on the immune system of Balb/C mice. The mice were immunized either by sheep red blood cells (SRBC) or by glutaric-anhydride conjugated bovine serum albumin (GA-BSA), then exposed to the microwaves at a low rms power density (30 microW/cm2; whole-body-averaged SAR approximately 0.015 W/kg). Sham exposure or microwave irradiation took place during each of five contiguous days, 10 h/day. The antibody response was evaluated by the plaque-forming cell assay (SRBC experiment) or by the titration of IgM and IgG antibodies (GA-BSA experiment). In the absence of AM, the pulsed field did not greatly alter immune responsiveness. In contrast, exposure to the field under the combined-modulation condition resulted in significant, AM-frequency-dependent augmentation or weakening of immune responses.",
  "effect": "mixed",
  "evidence": "low",
  "extraction": {
    "studyType": "animal",
    "studyTypeLabel": "Animal study",
    "effectDirection": "mixed",
    "evidenceLabel": "Low",
    "population": "Balb/C mice",
    "sampleSize": "—",
    "exposure": "microwave · 9400 MHz · 0.015 W/kg · 5 contiguous days, 10 h/day",
    "confidencePct": "74",
    "peerReviewed": "yes",
    "mainFindings": "Mice were exposed to pulsed microwaves (9.4 GHz; 1 microsecond pulses at 1,000/s) with or without concurrent amplitude modulation (14–41 MHz). Without amplitude modulation, the pulsed field did not greatly alter immune responsiveness; with combined pulse-and-amplitude modulation, immune responses showed significant AM-frequency-dependent augmentation or weakening.",
    "outcomes": [
      "Antibody response (plaque-forming cell assay)",
      "IgM antibody titers",
      "IgG antibody titers",
      "Immune responsiveness"
    ],
    "limitations": [
      "Sample size not reported in abstract",
      "Details of randomization/blinding not reported in abstract",
      "Only short-term exposure (5 days) described in abstract",
      "Results described qualitatively",
      "effect sizes not provided in abstract"
    ],
    "keywords": [
      "microwaves",
      "pulsed microwaves",
      "amplitude modulation",
      "immune system",
      "antibody response",
      "Balb/C mice",
      "SAR",
      "plaque-forming cell assay",
      "IgM",
      "IgG"
    ],
    "hubs": [
      {
        "slug": "who-icnirp",
        "weight": "0.7",
        "reason": "Animal study of RF/microwave exposure with SAR reported; potentially relevant to exposure guideline discussions."
      }
    ],
    "raw": "{\n  \"study_type\": \"animal\",\n  \"exposure\": {\n    \"band\": \"microwave\",\n    \"source\": null,\n    \"frequency_mhz\": 9400,\n    \"sar_wkg\": 0.015,\n    \"duration\": \"5 contiguous days, 10 h/day\"\n  },\n  \"population\": \"Balb/C mice\",\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"Antibody response (plaque-forming cell assay)\",\n    \"IgM antibody titers\",\n    \"IgG antibody titers\",\n    \"Immune responsiveness\"\n  ],\n  \"main_findings\": \"Mice were exposed to pulsed microwaves (9.4 GHz; 1 microsecond pulses at 1,000/s) with or without concurrent amplitude modulation (14–41 MHz). Without amplitude modulation, the pulsed field did not greatly alter immune responsiveness; with combined pulse-and-amplitude modulation, immune responses showed significant AM-frequency-dependent augmentation or weakening.\",\n  \"effect_direction\": \"mixed\",\n  \"limitations\": [\n    \"Sample size not reported in abstract\",\n    \"Details of randomization/blinding not reported in abstract\",\n    \"Only short-term exposure (5 days) described in abstract\",\n    \"Results described qualitatively; effect sizes not provided in abstract\"\n  ],\n  \"evidence_strength\": \"low\",\n  \"confidence\": 0.74,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"microwaves\",\n    \"pulsed microwaves\",\n    \"amplitude modulation\",\n    \"immune system\",\n    \"antibody response\",\n    \"Balb/C mice\",\n    \"SAR\",\n    \"plaque-forming cell assay\",\n    \"IgM\",\n    \"IgG\"\n  ],\n  \"suggested_hubs\": [\n    {\n      \"slug\": \"who-icnirp\",\n      \"weight\": 0.25,\n      \"reason\": \"Animal study of RF/microwave exposure with SAR reported; potentially relevant to exposure guideline discussions.\"\n    }\n  ]\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/2012621/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=6670",
  "updated": "2026-02-21 21:09:11"
}