Share

The effect of continuous exposure to low frequency electric fields on three generations of mice: a pilot study

A A Marino, R O Becker, B Ullrich

PAPERmanualExperientia1976Animal studyEffect: harmEvidence: Very low

Abstract

Mice were allowed to mate, gestate, deliver and rear their offspring for 3 successive generations while being continuously exposed to 60 Hz electric fields. Mice exposed to vertical electric fields exhibited decreased body weights at 35 days postpartum and increased mortality rates for 3 successive generations. Mice exposed to horizontal electric fields exhibited decreased body weights for 2 successive generations.

AI evidence extraction

At a glance
Study type
Animal study
Effect direction
harm
Population
mice (3 successive generations)
Sample size
—
Exposure
ELF · 0.00006 MHz · continuous exposure across mating, gestation, delivery, and rearing for 3 successive generations
Evidence strength
Very low
Confidence: 74% · Peer-reviewed: yes

Main findings

Across three successive generations continuously exposed to 60 Hz electric fields, mice exposed to vertical fields had decreased body weights at 35 days postpartum and increased mortality rates for all three generations. Mice exposed to horizontal fields had decreased body weights for two successive generations.

Outcomes measured

  • body weight at 35 days postpartum
  • mortality rate

Limitations

  • Pilot study
  • Sample size not reported in abstract
  • Electric field strength/intensity not reported in abstract
  • Randomization/blinding and control conditions not described in abstract
View raw extracted JSON
{
  "study_type": "animal",
  "exposure": {
    "band": "ELF",
    "source": null,
    "frequency_mhz": 0.00006,
    "sar_wkg": null,
    "duration": "continuous exposure across mating, gestation, delivery, and rearing for 3 successive generations"
  },
  "population": "mice (3 successive generations)",
  "sample_size": null,
  "outcomes": [
    "body weight at 35 days postpartum",
    "mortality rate"
  ],
  "main_findings": "Across three successive generations continuously exposed to 60 Hz electric fields, mice exposed to vertical fields had decreased body weights at 35 days postpartum and increased mortality rates for all three generations. Mice exposed to horizontal fields had decreased body weights for two successive generations.",
  "effect_direction": "harm",
  "limitations": [
    "Pilot study",
    "Sample size not reported in abstract",
    "Electric field strength/intensity not reported in abstract",
    "Randomization/blinding and control conditions not described in abstract"
  ],
  "evidence_strength": "very_low",
  "confidence": 0.74,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "mice",
    "three generations",
    "continuous exposure",
    "60 Hz",
    "electric fields",
    "ELF",
    "body weight",
    "mortality",
    "vertical electric field",
    "horizontal electric field"
  ],
  "suggested_hubs": [
    {
      "slug": "elf-fields",
      "weight": 0.9,
      "reason": "Study involves continuous exposure to 60 Hz (ELF) electric fields in mice."
    }
  ]
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.

NNEMF synthesis

Synthesis pending.

Original record: rfsafe.org paper 6688

The effect of continuous exposure to low frequency electric fields on three generations of mice: a pilot study · Non-native EMF