  "id": 6818,
  "url": "https://nnemf.org/research/6818-effect-on-radio-frequency-human-exposure-of-mobile",
  "title": "Effect on radio frequency human exposure of mobile phone inside an enclosed metallic elevator",
  "authors": [
    "C. K. Tang",
    "K. H. Chan",
    "L. C. Fung",
    "S. W. Leung"
  ],
  "journal": "Microwave and Optical Technology Letters",
  "year": "2008",
  "doi": "10.1002/mop.23612",
  "pmid": null,
  "abstract": "The effects of the radio frequency human exposure to mobile phone, inside both partially and fully enclosed metallic elevators, have been analyzed. It has been found that the evaluated peak Specific Absorption Rate (SAR) and the whole body absorption power are increased only by a small percentage inside the partial enclosures as compared to the free space environment; whereas inside the full enclosure, the peak SAR and the whole body absorption power are significantly increased. The analysis suggest that the reason of such a high level of RF energy absorption inside a fully enclosed metallic elevator is mainly because of the resonance effect.",
  "effect": "harm",
  "evidence": "low",
  "extraction": {
    "studyType": "engineering",
    "studyTypeLabel": "engineering",
    "effectDirection": "harm",
    "evidenceLabel": "Low",
    "population": "Humans/mobile phone users in partially and fully enclosed metallic elevator environments",
    "sampleSize": "—",
    "exposure": "RF 100–3000 MHz",
    "confidencePct": "88",
    "peerReviewed": "yes",
    "mainFindings": "The analysis found that peak SAR and whole-body absorption power increased only by a small percentage in partially enclosed metallic elevators compared with free space. In fully enclosed metallic elevators, peak SAR and whole-body absorption power were significantly increased, which the authors attributed mainly to resonance effects.",
    "outcomes": [
      "peak Specific Absorption Rate (SAR)",
      "whole body absorption power"
    ],
    "limitations": [
      "No sample size reported in the abstract",
      "Frequency not reported in the abstract",
      "Exposure duration not reported in the abstract",
      "Findings are based on analysis of enclosed elevator environments and may not generalize beyond these settings"
    ],
    "keywords": [
      "radio frequency",
      "RF exposure",
      "mobile phone",
      "elevator",
      "metallic enclosure",
      "SAR",
      "whole body absorption power",
      "resonance"
    ],
    "hubs": [],
    "raw": "{\n  \"study_type\": \"engineering\",\n  \"exposure\": {\n    \"band\": \"RF\",\n    \"source\": \"mobile phone\",\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": null\n  },\n  \"population\": \"Humans/mobile phone users in partially and fully enclosed metallic elevator environments\",\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"peak Specific Absorption Rate (SAR)\",\n    \"whole body absorption power\"\n  ],\n  \"main_findings\": \"The analysis found that peak SAR and whole-body absorption power increased only by a small percentage in partially enclosed metallic elevators compared with free space. In fully enclosed metallic elevators, peak SAR and whole-body absorption power were significantly increased, which the authors attributed mainly to resonance effects.\",\n  \"effect_direction\": \"harm\",\n  \"limitations\": [\n    \"No sample size reported in the abstract\",\n    \"Frequency not reported in the abstract\",\n    \"Exposure duration not reported in the abstract\",\n    \"Findings are based on analysis of enclosed elevator environments and may not generalize beyond these settings\"\n  ],\n  \"evidence_strength\": \"low\",\n  \"confidence\": 0.88,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"radio frequency\",\n    \"RF exposure\",\n    \"mobile phone\",\n    \"elevator\",\n    \"metallic enclosure\",\n    \"SAR\",\n    \"whole body absorption power\",\n    \"resonance\"\n  ],\n  \"suggested_hubs\": []\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://doi.org/10.1002/mop.23612",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=6818",