  "id": 6898,
  "url": "https://nnemf.org/research/6898-extremely-low-frequency-pulsed-electromagnetic-fields-induce-apoptotic",
  "title": "Extremely low-frequency pulsed electromagnetic fields induce apoptotic, oxidative stress, inflammatory and aquaporin-related kidney alteration",
  "authors": [
    "Merve Pekince Özöner",
    "Ugur Seker",
    "Cemil Sert",
    "Mehmet Zahid Tuysuz",
    "Meral Yüksel",
    "Yasin Gökçe"
  ],
  "journal": "Journal of Molecular Histology",
  "year": "2026",
  "doi": "10.1007/s10735-026-10883-3",
  "pmid": null,
  "abstract": "Extremely low-frequency pulsed electromagnetic fields are used as a biotherapy method in various medical and experimental applications. However, the cellular effects of prolonged or intense exposure remain unclear. This study aimed to evaluate the effects of two different ELF-PEMF doses on kidney tissue over an 8 week period, investigating oxidative stress, apoptosis, inflammation, and aquaporin expression using biochemical, histopathological, and immunohistochemical methods. Forty male rats were assigned to control, sham, 1 mT, and 5 mT groups; the 1 mT and 5 mT groups were exposed to ELF-PEMF for four hours daily for eight weeks, while controls received no intervention. At the end of the experiment, kidney tissues were collected for histopathological (H&E and PAS), immunohistochemical and biochemical analyses. In kidney tissue exposed to ELF-PEMF, hyperemia, tubular degeneration, and proteinaceous casts were observed. 1 mT and 5 mT ELF-PEMF exposure increased BAX, Caspase-9, and TNF-α immunoreactivity compared to the control and sham groups, while no change was observed in BCL-2 expression. 5 mT group exposure to ELF-PEMF increased AQP3 expression, a critical water channel in cellular H2O2 permeability (p < 0.05). AQP5 expression was significantly increased in both the 1 mT and 5 mT groups compared to the control group (p < 0.05). Biochemical analyses showed that oxidative stress levels were significantly increased in both the 1 mT and 5 mT groups compared to the control group (p < 0.05). These findings suggest that, despite its recent use for its therapeutic properties, long-term exposure to ELF-PEMF may cause oxidative stress, apoptosis, and inflammation in renal tissue and alter the histological structure and cellular homeostasis.",
  "effect": "harm",
  "evidence": "very_low",
  "extraction": {
    "studyType": "animal",
    "studyTypeLabel": "Animal study",
    "effectDirection": "harm",
    "evidenceLabel": "Very low",
    "population": "Forty male rats assigned to control, sham, 1 mT ELF-PEMF, and 5 mT ELF-PEMF groups",
    "sampleSize": "40",
    "exposure": "ELF · 4 hours daily for 8 weeks",
    "confidencePct": "93",
    "peerReviewed": "yes",
    "mainFindings": "Kidney tissue exposed to 1 mT and 5 mT ELF-PEMF showed hyperemia, tubular degeneration, and proteinaceous casts. ELF-PEMF increased BAX, Caspase-9, TNF-α, AQP5, and oxidative stress markers; 5 mT exposure also increased AQP3, while BCL-2 did not change. The authors conclude that long-term ELF-PEMF exposure may cause oxidative stress, apoptosis, inflammation, and altered renal histology and cellular homeostasis in rats.",
    "outcomes": [
      "kidney histopathology",
      "hyperemia",
      "tubular degeneration",
      "proteinaceous casts",
      "BAX immunoreactivity",
      "Caspase-9 immunoreactivity",
      "TNF-α immunoreactivity",
      "BCL-2 expression",
      "AQP3 expression",
      "AQP5 expression",
      "oxidative stress"
    ],
    "limitations": [
      "Animal study in male rats",
      "Exposure frequency was not stated in the abstract",
      "Only two ELF-PEMF magnetic flux density groups",
      "1 mT and 5 mT",
      "were evaluated",
      "Study duration was 8 weeks"
    ],
    "keywords": [
      "ELF-PEMF",
      "extremely low-frequency pulsed electromagnetic fields",
      "kidney",
      "renal tissue",
      "rats",
      "oxidative stress",
      "apoptosis",
      "inflammation",
      "aquaporin",
      "AQP3",
      "AQP5",
      "BAX",
      "Caspase-9",
      "TNF-α"
    ],
    "hubs": [],
    "raw": "{\n  \"study_type\": \"animal\",\n  \"exposure\": {\n    \"band\": \"ELF\",\n    \"source\": null,\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": \"4 hours daily for 8 weeks\"\n  },\n  \"population\": \"Forty male rats assigned to control, sham, 1 mT ELF-PEMF, and 5 mT ELF-PEMF groups\",\n  \"sample_size\": 40,\n  \"outcomes\": [\n    \"kidney histopathology\",\n    \"hyperemia\",\n    \"tubular degeneration\",\n    \"proteinaceous casts\",\n    \"BAX immunoreactivity\",\n    \"Caspase-9 immunoreactivity\",\n    \"TNF-α immunoreactivity\",\n    \"BCL-2 expression\",\n    \"AQP3 expression\",\n    \"AQP5 expression\",\n    \"oxidative stress\"\n  ],\n  \"main_findings\": \"Kidney tissue exposed to 1 mT and 5 mT ELF-PEMF showed hyperemia, tubular degeneration, and proteinaceous casts. ELF-PEMF increased BAX, Caspase-9, TNF-α, AQP5, and oxidative stress markers; 5 mT exposure also increased AQP3, while BCL-2 did not change. The authors conclude that long-term ELF-PEMF exposure may cause oxidative stress, apoptosis, inflammation, and altered renal histology and cellular homeostasis in rats.\",\n  \"effect_direction\": \"harm\",\n  \"limitations\": [\n    \"Animal study in male rats\",\n    \"Exposure frequency was not stated in the abstract\",\n    \"Only two ELF-PEMF magnetic flux density groups, 1 mT and 5 mT, were evaluated\",\n    \"Study duration was 8 weeks\"\n  ],\n  \"evidence_strength\": \"very_low\",\n  \"confidence\": 0.93,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"ELF-PEMF\",\n    \"extremely low-frequency pulsed electromagnetic fields\",\n    \"kidney\",\n    \"renal tissue\",\n    \"rats\",\n    \"oxidative stress\",\n    \"apoptosis\",\n    \"inflammation\",\n    \"aquaporin\",\n    \"AQP3\",\n    \"AQP5\",\n    \"BAX\",\n    \"Caspase-9\",\n    \"TNF-α\"\n  ],\n  \"suggested_hubs\": []\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://link.springer.com/article/10.1007/s10735-026-10883-3",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=6898",
  "updated": "2026-07-07 13:42:31"
}