{
  "id": 6940,
  "url": "https://nnemf.org/research/6940-rf-emf-brain-dose-from-mobile-phones-and",
  "title": "RF-EMF brain dose from mobile phones and the role of reception quality – a simulation study using the ETAIN 5G Scientist App",
  "authors": [
    "Lea Beláčková",
    "Hamed Jalilian",
    "Nekane Sandoval Diez",
    "Berend den Boer",
    "Hanne Herssens",
    "Lloyd Roga",
    "Marco Zahner",
    "Jürg Fröhlich",
    "Arno Thielens",
    "Martin Röösli",
    "Anke Huss"
  ],
  "journal": "",
  "year": "",
  "doi": "10.1016/j.envres.2026.125736",
  "pmid": null,
  "abstract": "Telecommunication technology continues to evolve, with recent transition from 4G to 5G networks. This can change radio-frequency electromagnetic field (RF-EMF) exposure from mobile devices. To accurately assess personal exposure, mobile device use in various environments with different network qualities should be considered when investigating exposure levels. Using the “ETAIN 5G-Scientist” app, we collected the signal strength quality indicators for both, 4G-LTE and 5G-NR: Reference Signal Received Power and Synchronization Signal Reference Signal Received Power (RSRP and ss-RSRP), for the main providers in the Netherlands (2024-2025). We used calibration functions to estimate far-field exposure from collected RSRP and ss-RSRP. We calculated the corresponding brain dose, based on previously developed specific absorption rate and simulated RF-EMF brain dose for a range of typical activities with mobile phones. We observed signal strength indicators ranging from -140 to -56 dBm RSRP (4G-LTE, N=150789) and -125 to -61 dBm ss-RSRP (5G-NR, N=2192). For the same type of mobile phone use, this, resulted in different estimated daily brain dose (mJ kg-1 day-1) levels. During the suboptimal network quality (RSRP: -120 dBm) the daily brain dose was higher (5 min call, 150 mJ kg-1 day-1; 5 min watching video, 26 mJ kg-1 day-1) compared to optimal network quality (RSRP: -60 dBm)(5 minute call, 4 mJ kg-1 day-1; 5 min watching video, 5 mJ kg-1 day-1). Our model based estimate show that even a few minutes of calling under suboptimal signal quality conditions resulted in higher brain dose than 24h environmental exposures. Personal RF-EMF exposure from mobile phones is strongly determined by the technology and the associated signal quality, this should be factored in when doing exposure studies or epidemiological research.",
  "effect": "unclear",
  "evidence": "low",
  "extraction": {
    "studyType": "exposure_assessment",
    "studyTypeLabel": "exposure assessment",
    "effectDirection": "unclear",
    "evidenceLabel": "Low",
    "population": "—",
    "sampleSize": "—",
    "exposure": "RF mobile phones (4G-LTE and 5G-NR) · Modeled 5-minute calls and video viewing; compared with 24-hour environmental exposure",
    "confidencePct": "94",
    "peerReviewed": "yes",
    "mainFindings": "Estimated brain dose was higher under suboptimal than optimal network quality for the same mobile-phone activity. For a 5-minute call, estimates were 150 versus 4 mJ kg-1 day-1, respectively; for 5 minutes of video viewing, they were 26 versus 5 mJ kg-1 day-1. The model estimated that a few minutes of calling under suboptimal signal quality produced a higher brain dose than 24 hours of environmental exposure.",
    "outcomes": [
      "Estimated RF-EMF brain dose",
      "Signal strength indicators (RSRP and ss-RSRP)"
    ],
    "limitations": [
      "Brain doses were model-based estimates",
      "not measured health outcomes.",
      "The abstract does not report the number of individual participants or devices."
    ],
    "keywords": [
      "RF-EMF",
      "mobile phones",
      "4G-LTE",
      "5G-NR",
      "brain dose",
      "reception quality",
      "exposure assessment",
      "simulation"
    ],
    "hubs": [],
    "raw": "{\n  \"study_type\": \"exposure_assessment\",\n  \"exposure\": {\n    \"band\": \"RF\",\n    \"source\": \"mobile phones (4G-LTE and 5G-NR)\",\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": \"Modeled 5-minute calls and video viewing; compared with 24-hour environmental exposure\"\n  },\n  \"population\": null,\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"Estimated RF-EMF brain dose\",\n    \"Signal strength indicators (RSRP and ss-RSRP)\"\n  ],\n  \"main_findings\": \"Estimated brain dose was higher under suboptimal than optimal network quality for the same mobile-phone activity. For a 5-minute call, estimates were 150 versus 4 mJ kg-1 day-1, respectively; for 5 minutes of video viewing, they were 26 versus 5 mJ kg-1 day-1. The model estimated that a few minutes of calling under suboptimal signal quality produced a higher brain dose than 24 hours of environmental exposure.\",\n  \"effect_direction\": \"unclear\",\n  \"limitations\": [\n    \"Brain doses were model-based estimates, not measured health outcomes.\",\n    \"The abstract does not report the number of individual participants or devices.\"\n  ],\n  \"evidence_strength\": \"low\",\n  \"confidence\": 0.94,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"RF-EMF\",\n    \"mobile phones\",\n    \"4G-LTE\",\n    \"5G-NR\",\n    \"brain dose\",\n    \"reception quality\",\n    \"exposure assessment\",\n    \"simulation\"\n  ],\n  \"suggested_hubs\": []\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://www.sciencedirect.com/science/article/abs/pii/S0013935126020670?via%3Dihub",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=6940",
  "updated": "2026-09-28 00:01:12"
}