{
  "id": 6964,
  "url": "https://nnemf.org/research/6964-24h-extremely-low-frequency-electromagnetic-field-exposure-modulates",
  "title": "24h Extremely Low Frequency Electromagnetic Field Exposure Modulates Immune Responses in Rats",
  "authors": [
    "Marina Nikolaishvili",
    "Aleksandre Tarkhnishvili",
    "Ketevan Phevadze",
    "David Natadze",
    "Khatuna Dondoladze"
  ],
  "journal": "WSEAS TRANSACTIONS on BIOLOGY and BIOMEDICINE",
  "year": "2026",
  "doi": "10.37394/23208.2026.23.30",
  "pmid": null,
  "abstract": "We examined the immune response induced by 24-hour continuous exposure to an ultra-low-frequency electromagnetic field (EMF) in white rats. We placed the experimental group wild-type albino rats in a special coil generating an electromagnetic field of 2 mT at a frequency of 50 Hz for 24 hours. The results of the study demonstrate that after 24 hours of continuous exposure to electromagnetic field, a significant increase in plasma potassium concentrations collected from the rats' tail veins was recorded (from 5.49 ± 0.46 to 13.07 ± 3.05 mmol/L). At the same time, the percentage of basophils in the blood increased significantly from 0.50 ± 0.09 to 1.03 ± 0.10%, while the platelet concentration decreased from 617.8 ± 15.2 × 10⁹/L to 323.5 ± 114.5 × 10⁹/L. The high standard deviation of immune system biomarkers allows us to conclude that the body responds through the involvement of individual mechanisms.",
  "effect": "unclear",
  "evidence": "low",
  "extraction": {
    "studyType": "animal",
    "studyTypeLabel": "Animal study",
    "effectDirection": "unclear",
    "evidenceLabel": "Low",
    "population": "Wild-type albino rats",
    "sampleSize": "—",
    "exposure": "ELF Laboratory coil generating a 2 mT electromagnetic field · 0.00005 MHz · 24 hours of continuous exposure",
    "confidencePct": "95",
    "peerReviewed": "yes",
    "mainFindings": "Following exposure, plasma potassium increased significantly from 5.49 ± 0.46 to 13.07 ± 3.05 mmol/L, and blood basophils increased significantly from 0.50 ± 0.09% to 1.03 ± 0.10%. Platelet concentration decreased from 617.8 ± 15.2 × 10⁹/L to 323.5 ± 114.5 × 10⁹/L.",
    "outcomes": [
      "Plasma potassium concentration",
      "Blood basophil percentage",
      "Platelet concentration"
    ],
    "limitations": [
      "Sample size is not reported in the abstract.",
      "Control-group conditions",
      "randomization",
      "and blinding are not described in the abstract.",
      "High variability in immune-system biomarkers is acknowledged by the authors.",
      "Only a single exposure duration and field setting are described."
    ],
    "keywords": [
      "extremely low frequency",
      "ELF-EMF",
      "50 Hz",
      "2 mT",
      "rats",
      "immune response",
      "plasma potassium",
      "basophils",
      "platelets",
      "24-hour exposure"
    ],
    "hubs": [],
    "raw": "{\n  \"study_type\": \"animal\",\n  \"exposure\": {\n    \"band\": \"ELF\",\n    \"source\": \"Laboratory coil generating a 2 mT electromagnetic field\",\n    \"frequency_mhz\": 0.00005,\n    \"sar_wkg\": null,\n    \"duration\": \"24 hours of continuous exposure\"\n  },\n  \"population\": \"Wild-type albino rats\",\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"Plasma potassium concentration\",\n    \"Blood basophil percentage\",\n    \"Platelet concentration\"\n  ],\n  \"main_findings\": \"Following exposure, plasma potassium increased significantly from 5.49 ± 0.46 to 13.07 ± 3.05 mmol/L, and blood basophils increased significantly from 0.50 ± 0.09% to 1.03 ± 0.10%. Platelet concentration decreased from 617.8 ± 15.2 × 10⁹/L to 323.5 ± 114.5 × 10⁹/L.\",\n  \"effect_direction\": \"unclear\",\n  \"limitations\": [\n    \"Sample size is not reported in the abstract.\",\n    \"Control-group conditions, randomization, and blinding are not described in the abstract.\",\n    \"High variability in immune-system biomarkers is acknowledged by the authors.\",\n    \"Only a single exposure duration and field setting are described.\"\n  ],\n  \"evidence_strength\": \"low\",\n  \"confidence\": 0.95,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"extremely low frequency\",\n    \"ELF-EMF\",\n    \"50 Hz\",\n    \"2 mT\",\n    \"rats\",\n    \"immune response\",\n    \"plasma potassium\",\n    \"basophils\",\n    \"platelets\",\n    \"24-hour exposure\"\n  ],\n  \"suggested_hubs\": []\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://wseas.com/journals/bab/2026/a605108-300.pdf",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=6964",
  "updated": "2026-11-02 19:39:54"
}