  "id": 734,
  "url": "https://nnemf.org/research/734-assessment-of-combined-exposure-to-intermediate-frequency-electromagnetic",
  "title": "Assessment of combined exposure to intermediate-frequency electromagnetic fields and pulsed electromagnetic fields among library workers in",
  "authors": [],
  "journal": "",
  "year": "2022",
  "doi": "10.3389/fpubh.2022.870784",
  "pmid": null,
  "abstract": "Assessment of combined exposure to intermediate-frequency electromagnetic fields and pulsed electromagnetic fields among library workers in Japan Yamaguchi-Sekino S, Taki M, Ikuyo M, Esaki K, Aimoto A, Wake K, Kojimahara N. Assessment of combined exposure to intermediate-frequency electromagnetic fields and pulsed electromagnetic fields among library workers in Japan. Front Public Health. 2022 Jul 28;10:870784. doi: 10.3389/fpubh.2022.870784. Abstract Objective: To assess exposure levels to electromagnetic fields (EMFs) among library workers in Japan, focusing on co-exposure to intermediate-frequency EMF (IF-EMF) and pulsed EMF, to propose a new epidemiological research methodology. Methods: The evaluated exposure sources were an electromagnetic type-electronic article surveillance gate (EM-EAS, IF-EMF (operating frequency 220 Hz-14 kHz)) and an activator/deactivator of anti-theft tags termed as \"book check unit\" (BCU, pulsed EMF). Short-term exposures were: (E1) whole-body exposure from the EAS gate when sitting within 3 m; (E2) local exposure to transient IF-EMF while passing through or beside the EAS gate; and (E3) local exposure to a pulsed magnetic field on BCU use. E1-E3 were evaluated based on exposure levels relative to magnetic flux density at the occupational reference level (RL; E1) or as per occupational basic restrictions (BR; E2 and E3) delineated by the International Commission on Non-Ionizing Radiation Protection (ICNIRP) 2010 guidelines. Exposure indices based on mid-term exposure (D1-D3), assuming exposure according to employment on a weekly basis, were used to assess exposure in actual working conditions. D1 represents continuous exposure from an EAS gate when sitting within 3 m of the gate. D2 and D3 represent repeated transient exposures occurring during gate pass or on the operation of a BCU. A link to a web-based questionnaire was distributed to librarians working at all libraries where the authors had mailed institutional questionnaires (4,073 libraries). Four exposure patterns were defined according to various exposure scenarios. Results: We obtained information on exposure parameters and working conditions from the 548 completed questionnaires. The ICNIRP guideline levels were not exceeded in any of the E1-E3 scenarios. Median of the D1 (% ICNIRP RL × hour/week) was 1, and >85% respondents had values <10. However, the maximum value was 513. Altogether, these results indicate that continuous exposure was low in most cases. The same tendency was observed regarding repeated transient exposure from EM-EAS gates (i.e., the median value for D2 (% ICNIRP BR × gate pass) was 5). However, there were several cases in which D1 and D2 values were >10 times the median. The median of D3 (% ICNIRP BR × BCU operation) was 10, and most respondents' D3 values were greater than their D2 values, although the derived results depended on the assumptions made for the estimation. Conclusion: We conducted an assessment of combined exposures to IF-EMF and pulsed EMF among library workers in Japan by evaluating both short-term exposures (E1-E3) and exposure indices based on mid-term exposures (D1-D3) assuming actual working conditions per questionnaire results. These results provide useful information for future epidemiological studies. : https://www.frontiersin.org/articles/10.3389/fpubh.2022.870784/full",
  "effect": "no_effect",
  "evidence": "low",
  "extraction": {
    "studyType": "exposure_assessment",
    "studyTypeLabel": "exposure assessment",
    "effectDirection": "no_effect",
    "evidenceLabel": "Low",
    "population": "Library workers (librarians) in Japan",
    "sampleSize": "548",
    "exposure": "IF occupational · Short-term scenarios (E1-E3) and mid-term/weekly indices (D1-D3) based on questionnaire-assumed working conditions",
    "confidencePct": "78",
    "peerReviewed": "yes",
    "mainFindings": "Across evaluated short-term scenarios (E1–E3), ICNIRP 2010 occupational guideline levels were not exceeded. For mid-term indices, median D1 was 1 (% ICNIRP RL × hour/week) with >85% of respondents <10, though the maximum D1 was 513; median D2 was 5 (% ICNIRP BR × gate pass) with some cases >10× the median. Median D3 was 10 (% ICNIRP BR × BCU operation), and most respondents’ D3 values were greater than their D2 values, with results depending on estimation assumptions.",
    "outcomes": [
      "Exposure levels to intermediate-frequency EMF (IF-EMF) from electromagnetic type electronic article surveillance (EM-EAS) gates (220 Hz–14 kHz)",
      "Exposure levels to pulsed EMF from activator/deactivator (“book check unit”",
      "BCU)",
      "Exposure indices relative to ICNIRP 2010 occupational reference levels (RL) and basic restrictions (BR) for scenarios E1–E3 and indices D1–D3"
    ],
    "limitations": [
      "Exposure indices (D1–D3) were estimated using assumptions about weekly work patterns and exposure frequency/duration based on questionnaire results",
      "Derived results for D3 were noted to depend on the assumptions made for estimation",
      "Working-condition data were obtained from completed questionnaires (548 responses) from a larger distribution (4",
      "073 libraries)",
      "implying potential response/selection limitations (not further detailed in abstract)"
    ],
    "keywords": [
      "intermediate-frequency EMF",
      "pulsed EMF",
      "occupational exposure",
      "library workers",
      "electronic article surveillance",
      "anti-theft gate",
      "book check unit",
      "ICNIRP 2010",
      "magnetic flux density",
      "questionnaire"
    ],
    "hubs": [
      {
        "slug": "occupational-exposure",
        "weight": "0.7",
        "reason": "Assesses EMF exposure among library workers in workplace settings."
      },
      {
        "slug": "who-icnirp",
        "weight": "0.7",
        "reason": "Exposure evaluation explicitly referenced ICNIRP 2010 occupational reference levels and basic restrictions."
      }
    ],
    "raw": "{\n  \"study_type\": \"exposure_assessment\",\n  \"exposure\": {\n    \"band\": \"IF\",\n    \"source\": \"occupational\",\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": \"Short-term scenarios (E1-E3) and mid-term/weekly indices (D1-D3) based on questionnaire-assumed working conditions\"\n  },\n  \"population\": \"Library workers (librarians) in Japan\",\n  \"sample_size\": 548,\n  \"outcomes\": [\n    \"Exposure levels to intermediate-frequency EMF (IF-EMF) from electromagnetic type electronic article surveillance (EM-EAS) gates (220 Hz–14 kHz)\",\n    \"Exposure levels to pulsed EMF from activator/deactivator (“book check unit”, BCU)\",\n    \"Exposure indices relative to ICNIRP 2010 occupational reference levels (RL) and basic restrictions (BR) for scenarios E1–E3 and indices D1–D3\"\n  ],\n  \"main_findings\": \"Across evaluated short-term scenarios (E1–E3), ICNIRP 2010 occupational guideline levels were not exceeded. For mid-term indices, median D1 was 1 (% ICNIRP RL × hour/week) with >85% of respondents <10, though the maximum D1 was 513; median D2 was 5 (% ICNIRP BR × gate pass) with some cases >10× the median. Median D3 was 10 (% ICNIRP BR × BCU operation), and most respondents’ D3 values were greater than their D2 values, with results depending on estimation assumptions.\",\n  \"effect_direction\": \"no_effect\",\n  \"limitations\": [\n    \"Exposure indices (D1–D3) were estimated using assumptions about weekly work patterns and exposure frequency/duration based on questionnaire results\",\n    \"Derived results for D3 were noted to depend on the assumptions made for estimation\",\n    \"Working-condition data were obtained from completed questionnaires (548 responses) from a larger distribution (4,073 libraries), implying potential response/selection limitations (not further detailed in abstract)\"\n  ],\n  \"evidence_strength\": \"low\",\n  \"confidence\": 0.78,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"intermediate-frequency EMF\",\n    \"pulsed EMF\",\n    \"occupational exposure\",\n    \"library workers\",\n    \"electronic article surveillance\",\n    \"anti-theft gate\",\n    \"book check unit\",\n    \"ICNIRP 2010\",\n    \"magnetic flux density\",\n    \"questionnaire\"\n  ],\n  \"suggested_hubs\": [\n    {\n      \"slug\": \"occupational-exposure\",\n      \"weight\": 0.95,\n      \"reason\": \"Assesses EMF exposure among library workers in workplace settings.\"\n    },\n    {\n      \"slug\": \"who-icnirp\",\n      \"weight\": 0.7,\n      \"reason\": \"Exposure evaluation explicitly referenced ICNIRP 2010 occupational reference levels and basic restrictions.\"\n    }\n  ]\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://www.frontiersin.org/articles/10.3389/fpubh.2022.870784/full",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=734",
  "updated": "2026-02-10 10:54:50"
}