Share

Oxidative stress and energy metabolism in male reproductive damage from single and combined high-

PAPERmanualReproductive Toxicology2024Animal studyEffect: harmEvidence: Low

Abstract

Oxidative stress and energy metabolism in male reproductive damage from single and combined high- power microwave exposure at 1.5 and 4.3GHz Li Y, Yao B, Men J, Pang Y, Gao J, Bai Y, Wang H, Zhang J, Zhao L, Xu X, Dong J, Li C, Peng R. Oxidative stress and energy metabolism in male reproductive damage from single and combined high-power microwave exposure at 1.5 and 4.3GHz. Reprod Toxicol. 2024 Nov 29;132:108759. doi: 10.1016/j.reprotox.2024.108759. Abstract The effect of multi-frequency electromagnetic environments on male reproduction has attracted the medical community's interest. Studies have investigated the effects and mechanisms of single-frequency microwave exposure on male reproduction, but comparative research on high-power microwave (HPM) composite and single exposure remains scarce. This study aimed to examine the effects and mechanisms of combined 1.5 GHz and 4.3 GHz microwave exposure on male reproduction. Male Wistar rats were exposed to 1.5 GHz (L-band) and 4.3 GHz (C-band) electromagnetic radiation for 15 minutes. The four groups were: sham, 10 mW/cm2 L-band, 10 mW/cm2 C-band, and 5 mW/cm2 L-band and 5 mW/cm2 C- band compound. Assessments were made on the pathological structures of testes, sperm viability, serum sex hormones, oxidative stress, and energy metabolism levels after radiation. Exposure to 1.5 GHz and 4.3 GHz microwaves individually resulted in testicular tissue damage and reduced sperm quality. There was little difference between the damage caused by HPM composite and single exposure. The exposed groups showed histological and ultrastructural changes, with reduced spermatozoa viability, motility parameters, and serum testosterone, luteinizing hormone, follicle-stimulating hormone, and serum inhibin-B on days 1 and 7 after exposure. These tended to recover partially by day 14. Adenosine triphosphate content and lactate dehydrogenase and succinate dehydrogenase activities in the exposed testicular tissue decreased, corresponding to decreased superoxide dismutase activity and increased malondialdehyde content. Both single and combined exposure to L- and C-band HPM affect the male reproductive system. Exposure to single and compound HPM shows no significant difference in risks, with oxidative stress and energy metabolism disturbances playing key roles. : sciencedirect.com

AI evidence extraction

At a glance
Study type
Animal study
Effect direction
harm
Population
Male Wistar rats
Sample size
—
Exposure
microwave high-power microwave exposure (electromagnetic radiation) · 15 minutes
Evidence strength
Low
Confidence: 78% · Peer-reviewed: yes

Main findings

Male Wistar rats exposed for 15 minutes to 1.5 GHz or 4.3 GHz microwaves showed testicular tissue damage and reduced sperm quality, with decreased sperm viability/motility and reduced serum testosterone, luteinizing hormone, follicle-stimulating hormone, and inhibin-B on days 1 and 7 post-exposure, with partial recovery by day 14. Testicular ATP content and LDH/SDH activities decreased alongside decreased SOD activity and increased MDA content. The abstract reports little difference in damage between single-frequency and combined (compound) exposure groups.

Outcomes measured

  • Testicular pathological structure (histology/ultrastructure)
  • Sperm viability
  • Sperm motility parameters
  • Serum sex hormones (testosterone
  • luteinizing hormone
  • follicle-stimulating hormone
  • inhibin-B)
  • Oxidative stress markers (superoxide dismutase activity
  • malondialdehyde content)
  • Energy metabolism markers (ATP content
  • lactate dehydrogenase activity
  • succinate dehydrogenase activity)

Limitations

  • Sample size not reported in provided abstract/metadata
  • SAR not reported
  • exposure described in power density (mW/cm2) only
  • Short exposure duration (15 minutes) with limited follow-up timepoints (days 1
  • 7
  • 14)
  • Details of randomization/blinding and exposure setup not provided in the abstract
View raw extracted JSON
{
  "study_type": "animal",
  "exposure": {
    "band": "microwave",
    "source": "high-power microwave exposure (electromagnetic radiation)",
    "frequency_mhz": null,
    "sar_wkg": null,
    "duration": "15 minutes"
  },
  "population": "Male Wistar rats",
  "sample_size": null,
  "outcomes": [
    "Testicular pathological structure (histology/ultrastructure)",
    "Sperm viability",
    "Sperm motility parameters",
    "Serum sex hormones (testosterone, luteinizing hormone, follicle-stimulating hormone, inhibin-B)",
    "Oxidative stress markers (superoxide dismutase activity, malondialdehyde content)",
    "Energy metabolism markers (ATP content, lactate dehydrogenase activity, succinate dehydrogenase activity)"
  ],
  "main_findings": "Male Wistar rats exposed for 15 minutes to 1.5 GHz or 4.3 GHz microwaves showed testicular tissue damage and reduced sperm quality, with decreased sperm viability/motility and reduced serum testosterone, luteinizing hormone, follicle-stimulating hormone, and inhibin-B on days 1 and 7 post-exposure, with partial recovery by day 14. Testicular ATP content and LDH/SDH activities decreased alongside decreased SOD activity and increased MDA content. The abstract reports little difference in damage between single-frequency and combined (compound) exposure groups.",
  "effect_direction": "harm",
  "limitations": [
    "Sample size not reported in provided abstract/metadata",
    "SAR not reported; exposure described in power density (mW/cm2) only",
    "Short exposure duration (15 minutes) with limited follow-up timepoints (days 1, 7, 14)",
    "Details of randomization/blinding and exposure setup not provided in the abstract"
  ],
  "evidence_strength": "low",
  "confidence": 0.78,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "high-power microwave",
    "microwave exposure",
    "1.5 GHz",
    "4.3 GHz",
    "L-band",
    "C-band",
    "male reproduction",
    "testis",
    "sperm quality",
    "testosterone",
    "oxidative stress",
    "energy metabolism",
    "ATP",
    "SOD",
    "MDA"
  ],
  "suggested_hubs": [
    {
      "slug": "animal-studies",
      "weight": 0.9,
      "reason": "Experimental exposure study in male Wistar rats assessing reproductive outcomes."
    }
  ]
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.

NNEMF synthesis

1. What they did Male Wistar rats received a single 15-minute high-power microwave exposure. Frequencies were 1.5 gigahertz (L-band) and 4.3 gigahertz (C-band). Groups were sham, 10 milliwatts per square centimeter L-band, 10 milliwatts per square centimeter C-band, and a compound group at 5 milliwatts per square centimeter of each band. After exposure, investigators assessed testicular histology and ultrastructure, sperm viability and motility, and serum testosterone, luteinizing hormone, follicle-stimulating hormone, and inhibin-B on days 1, 7, and 14. In testicular tissue they measured adenosine triphosphate (ATP, the cell’s main energy currency), lactate dehydrogenase, succinate dehydrogenase (a mitochondrial energy enzyme), superoxide dismutase (an enzyme that handles reactive oxygen molecules), and malondialdehyde (a product that rises when fats are oxidized). 2. What they found Each single-frequency exposure was followed by histological and ultrastructural changes in the testis and by lower sperm viability and motility. Serum testosterone, luteinizing hormone, follicle-stimulating hormone, and inhibin-B were lower on days 1 and 7 and tended to recover partially by day 14. ATP content and lactate dehydrogenase and succinate dehydrogenase activities decreased in exposed testicular tissue. Superoxide dismutase activity decreased and malondialdehyde content increased. Combined exposure produced little difference from either single exposure; the record states no significant difference between single and compound conditions. 3. How it connects These results show the mitochondria-and-redox step. Lower succinate dehydrogenase activity and lower ATP are a drop in mitochondrial energy output; lower superoxide dismutase with higher malondialdehyde is a shift in redox balance. That pattern, with hormone measures only partly restored by day 14, matches the framework prediction that microwave exposure can disturb mitochondrial energy and redox output and draw on cellular reserve. Effects of Long-Term Exposure to L-Band (~2.0 GHz) High-Power (0.5, 1.0, and 1.5 W/m2) Microwave on the Brain Function of Male Mice is parallel: it measured brain function and oxidative stress in male mice after L-band high-power microwave, the same redox step measured here in rat testis at 1.5 and 4.3 gigahertz. 4. Limits Modulation, pulsing, and specific absorption rate were not reported, so these power densities cannot be compared with the 1.6 watts per kilogram phone limit.

Original record: rfsafe.org paper 77