  "id": 925,
  "url": "https://nnemf.org/research/925-assessment-of-cortisol-secretory-pattern-in-workers-chronically",
  "title": "Assessment of cortisol secretory pattern in workers chronically exposed to ELF-EMF generated by high voltage transmission lines and substation",
  "authors": [],
  "journal": "",
  "year": "2022",
  "doi": "10.1016/j.envint.2022.107103",
  "pmid": null,
  "abstract": "Assessment of cortisol secretory pattern in workers chronically exposed to ELF-EMF generated by high voltage transmission lines and substation Yvan Touitou, Brahim Selmaoui, Jacques Lambrozo. Assessment of cortisol secretory pattern in workers chronically exposed to ELF-EMF generated by high voltage transmission lines and substations. Environ Int. 2022 Feb 1;161:107103. doi: 10.1016/j.envint.2022.107103 Abstract We investigated the effects of extremely-low frequency electromagnetic fields (ELF-EMFs; 50 Hz) on the secretion of cortisol in 14 men (mean age = 38.0 ± 0.9 years) working in extra-high voltage (EHV) substations. The workers dwelt in houses that were close to substations and high-voltage lines. Thus, they had long histories (1-20 years) of long-yerm exposure to ELF-EMFs. Magnetic field strength was recorded using Emdex dosimeters worn by the volunteers day and night for seven days; the one-week geometric mean ranged from 0.1 to 2.6 μT. Blood samples were taken hourly from 20:00 to 08:00 the next morning. Cortisol concentrations and patterns were compared to age-matched, unexposed control subjects whose exposure level was ten times lower. The comparison of the control group (n = 15) and the groups exposed to fields of 0.1-0.3 μT (n = 5) and > 0.3 μT (n = 9), respectively, revealed a significant effect of field intensity on the cortisol secretory pattern. This study strongly suggests that chronic exposure to ELF-EMFs alters the peak-time serum cortisol levels. Studies are required on the effect of this disruption in high-risk populations such as children, elderly people, and patients with cancer. Highlights • Health risks, including cancer, are associated with exposure to electric and magnetic fields. • Most available literature describes biological changes following short-term exposure. • Additional effects due to long-term exposure cannot be ruled out. • Hypothalamic-pituitary-adrenal axis and ELF-EMF relationship has been highlighted. • We report a decline in the peak-time concentration of cortisol in workers exposed for 1 to 20 years. • Cortisol secretion and the related biological mechanisms should be monitored in long-term exposure to ELF- EMF. : https://www.sciencedirect.com/science/article/pii/S0160412022000290",
  "effect": "harm",
  "evidence": "low",
  "extraction": {
    "studyType": "cohort",
    "studyTypeLabel": "cohort",
    "effectDirection": "harm",
    "evidenceLabel": "Low",
    "population": "Male workers in extra-high voltage (EHV) substations (mean age 38.0 ± 0.9 years) and age-matched unexposed controls",
    "sampleSize": "29",
    "exposure": "ELF occupational · 0.00005 MHz · Chronic exposure for 1–20 years; personal monitoring day and night for 7 days",
    "confidencePct": "78",
    "peerReviewed": "yes",
    "mainFindings": "In a comparison between controls (n=15) and workers grouped by magnetic field exposure (0.1–0.3 µT, n=5; >0.3 µT, n=9), the authors report a significant effect of field intensity on the cortisol secretory pattern. The study reports a decline in peak-time serum cortisol concentration in chronically exposed workers.",
    "outcomes": [
      "Serum cortisol concentrations",
      "Cortisol secretory pattern (including peak-time levels)"
    ],
    "limitations": [
      "Small sample size (14 exposed workers)",
      "Only men were studied",
      "Exposure assessment reported for one week",
      "while exposure history spans 1–20 years",
      "Outcome sampling limited to overnight period (20:00–08:00)",
      "Potential confounding factors are not described in the abstract"
    ],
    "keywords": [
      "extremely-low frequency electromagnetic fields",
      "ELF-EMF",
      "50 Hz",
      "extra-high voltage substations",
      "high voltage transmission lines",
      "magnetic field strength",
      "dosimeter",
      "Emdex",
      "cortisol",
      "secretory pattern",
      "hypothalamic-pituitary-adrenal axis",
      "chronic exposure"
    ],
    "hubs": [
      {
        "slug": "occupational-exposure",
        "weight": "0.7",
        "reason": "Study population is workers in extra-high voltage substations with chronic occupational ELF-EMF exposure."
      },
      {
        "slug": "power-lines",
        "weight": "0.7",
        "reason": "Exposure source includes high-voltage transmission lines and substations."
      }
    ],
    "raw": "{\n  \"publication_year\": 2022,\n  \"study_type\": \"cohort\",\n  \"exposure\": {\n    \"band\": \"ELF\",\n    \"source\": \"occupational\",\n    \"frequency_mhz\": 0.00005,\n    \"sar_wkg\": null,\n    \"duration\": \"Chronic exposure for 1–20 years; personal monitoring day and night for 7 days\"\n  },\n  \"population\": \"Male workers in extra-high voltage (EHV) substations (mean age 38.0 ± 0.9 years) and age-matched unexposed controls\",\n  \"sample_size\": 29,\n  \"outcomes\": [\n    \"Serum cortisol concentrations\",\n    \"Cortisol secretory pattern (including peak-time levels)\"\n  ],\n  \"main_findings\": \"In a comparison between controls (n=15) and workers grouped by magnetic field exposure (0.1–0.3 µT, n=5; >0.3 µT, n=9), the authors report a significant effect of field intensity on the cortisol secretory pattern. The study reports a decline in peak-time serum cortisol concentration in chronically exposed workers.\",\n  \"effect_direction\": \"harm\",\n  \"limitations\": [\n    \"Small sample size (14 exposed workers)\",\n    \"Only men were studied\",\n    \"Exposure assessment reported for one week, while exposure history spans 1–20 years\",\n    \"Outcome sampling limited to overnight period (20:00–08:00)\",\n    \"Potential confounding factors are not described in the abstract\"\n  ],\n  \"evidence_strength\": \"low\",\n  \"confidence\": 0.78,\n  \"peer_reviewed_likely\": \"yes\",\n  \"stance\": \"concern\",\n  \"stance_confidence\": 0.74,\n  \"summary\": \"This study examined whether chronic occupational exposure to 50 Hz ELF-EMF in extra-high voltage substation workers is associated with changes in cortisol secretion. Personal magnetic-field measurements over seven days (geometric mean 0.1–2.6 µT) were used to classify exposure, and hourly blood samples were collected overnight. Compared with age-matched controls with much lower exposure, field intensity was reported to significantly affect cortisol secretory pattern, including a decline in peak-time cortisol in exposed workers.\",\n  \"key_points\": [\n    \"The study evaluated 50 Hz ELF-EMF exposure in 14 male EHV substation workers with 1–20 years of exposure history.\",\n    \"Magnetic field exposure was measured with Emdex dosimeters worn day and night for seven days, with a one-week geometric mean of 0.1–2.6 µT.\",\n    \"Controls (n=15) were age-matched and reported to have exposure levels ten times lower than workers.\",\n    \"Blood was sampled hourly from 20:00 to 08:00 to assess overnight cortisol secretion patterns.\",\n    \"Cortisol secretory pattern differed by exposure intensity when comparing controls to workers exposed to 0.1–0.3 µT and >0.3 µT.\",\n    \"The authors report a decline in peak-time cortisol concentration in chronically exposed workers and call for further studies in high-risk populations.\"\n  ],\n  \"categories\": [\n    \"Occupational Exposure\",\n    \"Power Lines & Substations\",\n    \"Endocrine Effects\",\n    \"ELF (Extremely Low Frequency)\"\n  ],\n  \"tags\": [\n    \"ELF-EMF\",\n    \"50 Hz\",\n    \"Occupational Exposure\",\n    \"Extra-High Voltage Substation\",\n    \"High-Voltage Transmission Lines\",\n    \"Magnetic Field Dosimetry\",\n    \"Emdex Dosimeter\",\n    \"Cortisol\",\n    \"HPA Axis\",\n    \"Circadian Rhythm\",\n    \"Chronic Exposure\"\n  ],\n  \"keywords\": [\n    \"extremely-low frequency electromagnetic fields\",\n    \"ELF-EMF\",\n    \"50 Hz\",\n    \"extra-high voltage substations\",\n    \"high voltage transmission lines\",\n    \"magnetic field strength\",\n    \"dosimeter\",\n    \"Emdex\",\n    \"cortisol\",\n    \"secretory pattern\",\n    \"hypothalamic-pituitary-adrenal axis\",\n    \"chronic exposure\"\n  ],\n  \"suggested_hubs\": [\n    {\n      \"slug\": \"occupational-exposure\",\n      \"weight\": 0.86,\n      \"reason\": \"Study population is workers in extra-high voltage substations with chronic occupational ELF-EMF exposure.\"\n    },\n    {\n      \"slug\": \"power-lines\",\n      \"weight\": 0.8,\n      \"reason\": \"Exposure source includes high-voltage transmission lines and substations.\"\n    }\n  ],\n  \"social\": {\n    \"tweet\": \"Study of 14 EHV substation workers (50 Hz ELF-EMF) with 1–20 years exposure found field intensity was linked to altered overnight cortisol secretion patterns, including reduced peak-time cortisol vs age-matched controls. More research in high-risk groups was recommended.\",\n    \"facebook\": \"Researchers measured 50 Hz ELF-EMF exposure in extra-high voltage substation workers and collected hourly overnight blood samples. Compared with age-matched controls, exposure intensity was reported to significantly affect cortisol secretion patterns, including reduced peak-time cortisol in chronically exposed workers.\",\n    \"linkedin\": \"In an occupational study of extra-high voltage substation workers, personal 50 Hz magnetic-field monitoring (0.1–2.6 µT geometric mean over 7 days) and hourly overnight blood sampling suggested exposure intensity was associated with changes in cortisol secretory pattern, including reduced peak-time cortisol vs controls. Further studies were recommended.\"\n  }\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://www.sciencedirect.com/science/article/pii/S0160412022000290",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=925",
  "updated": "2026-02-10 11:16:16"
}