Share

Can body-worn devices be used for measuring personal exposure to mm waves?

PAPERmanual2017engineeringEffect: unclearEvidence: Insufficient

Abstract

Can body-worn devices be used for measuring personal exposure to mm waves?

AI evidence extraction

At a glance
Study type
engineering
Effect direction
unclear
Population
—
Sample size
—
Exposure
RF >3000 MHz
Evidence strength
Insufficient
Confidence: 74% · Peer-reviewed: yes

Main findings

Using a simplified model, the authors estimate measurement dynamic range limits of 53 dB at 300 GHz and 73 dB at 30 GHz due to reduced antenna aperture, exposure guideline limits on incident power density, and increased noise floor. They state that additional on-body propagation losses can exceed this dynamic range, so on-body measurement of incident power density cannot be guaranteed using a single antenna; they propose multiple dynamic antennas on the body instead.

Outcomes measured

  • Feasibility/limitations of on-body personal exposure measurements at mmWave frequencies
  • Dynamic range limits for incident power density measurements (model-based)

Limitations

  • Results are based on a simplified model (as stated)
  • No empirical measurement data described in the abstract

Suggested hubs

  • 5g-policy (0.7)
    Discusses mmWave (30–300 GHz) exposure measurement challenges in the context of future 5G networks.
  • occupational-exposure (0.7)
    Abstract explicitly notes the issue is problematic for occupational measurements.
View raw extracted JSON
{
  "study_type": "engineering",
  "exposure": {
    "band": "mmWave",
    "source": "5G telecommunication networks",
    "frequency_mhz": null,
    "sar_wkg": null,
    "duration": null
  },
  "population": null,
  "sample_size": null,
  "outcomes": [
    "Feasibility/limitations of on-body personal exposure measurements at mmWave frequencies",
    "Dynamic range limits for incident power density measurements (model-based)"
  ],
  "main_findings": "Using a simplified model, the authors estimate measurement dynamic range limits of 53 dB at 300 GHz and 73 dB at 30 GHz due to reduced antenna aperture, exposure guideline limits on incident power density, and increased noise floor. They state that additional on-body propagation losses can exceed this dynamic range, so on-body measurement of incident power density cannot be guaranteed using a single antenna; they propose multiple dynamic antennas on the body instead.",
  "effect_direction": "unclear",
  "limitations": [
    "Results are based on a simplified model (as stated)",
    "No empirical measurement data described in the abstract"
  ],
  "evidence_strength": "insufficient",
  "confidence": 0.74,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "5G",
    "millimeter waves",
    "mmWave",
    "30-300 GHz",
    "personal exposure",
    "body-worn devices",
    "on-body measurements",
    "incident power density",
    "dynamic range",
    "antenna aperture",
    "occupational measurements",
    "epidemiological studies"
  ],
  "suggested_hubs": [
    {
      "slug": "5g-policy",
      "weight": 0.62,
      "reason": "Discusses mmWave (30–300 GHz) exposure measurement challenges in the context of future 5G networks."
    },
    {
      "slug": "occupational-exposure",
      "weight": 0.55,
      "reason": "Abstract explicitly notes the issue is problematic for occupational measurements."
    }
  ]
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.

NNEMF synthesis

Synthesis pending.

Original record: rfsafe.org paper 1379

Can body-worn devices be used for measuring personal exposure to mm waves? · Non-native EMF