Share

Possible Mechanism for Synchronized Detection of Weak Magnetic Fields by Nerve

PAPERmanual2020ReviewEffect: unclearEvidence: Insufficient

Abstract

Possible Mechanism for Synchronized Detection of Weak Magnetic Fields by Nerve Cells Barnes F, Greenebaum B. Possible Mechanism for Synchronized Detection of Weak Magnetic Fields by Nerve Cells. Bioelectromagnetics. Published online Jan 28, 2020. doi.org Abstract We propose that biological systems may detect static and slowly varying magnetic fields by the modification of the timing of firing of adjacent nerve cells through the local influence of the magnetic field generated by current from one cell's firing on its nearest neighbors. The time delay of an adjacent nerve cell pulse with respect to the initial clock nerve cell pulse could serve as a signal for sensing the magnitude and direction of the magnetic field in a direction perpendicular to the current flows in the cells. It has been shown that changes in static magnetic fields modify concentrations of reactive oxygen species, calcium, pH, the growth rates of fibrosarcoma cells, and membrane potentials. These are linked to changes in membrane potentials that can either inhibit or accelerate the firing rate of pacemaker or clock cells. This mechanism may have applications to animals' use of magnetic fields for navigation or other purposes, possibly in conjunction with other mechanisms. onlinelibrary.wiley.com

AI evidence extraction

At a glance
Study type
Review
Effect direction
unclear
Population
—
Sample size
—
Exposure
ELF <1 MHz
Evidence strength
Insufficient
Confidence: 74% · Peer-reviewed: yes

Main findings

The authors propose a mechanism by which biological systems could detect static and slowly varying magnetic fields via magnetic-field-induced modifications in the timing of firing of adjacent nerve cells, mediated by local magnetic fields generated by currents during firing. They note prior findings that changes in static magnetic fields modify ROS, calcium, pH, fibrosarcoma cell growth rates, and membrane potentials, which are linked to changes in membrane potentials that can inhibit or accelerate firing of pacemaker/clock cells.

Outcomes measured

  • Nerve cell firing timing/synchronization
  • Detection of static and slowly varying magnetic fields
  • Reactive oxygen species (ROS)
  • Calcium
  • pH
  • Fibrosarcoma cell growth rates
  • Membrane potentials
  • Pacemaker/clock cell firing rate
  • Animal magnetoreception/navigation (proposed application)

Limitations

  • Mechanistic proposal rather than a reported experimental study in the abstract
  • No quantitative exposure metrics (field strength
  • frequency) provided in the abstract
  • No described study population
  • methods
  • or sample size in the abstract
View raw extracted JSON
{
  "study_type": "review",
  "exposure": {
    "band": "ELF",
    "source": "other",
    "frequency_mhz": null,
    "sar_wkg": null,
    "duration": null
  },
  "population": null,
  "sample_size": null,
  "outcomes": [
    "Nerve cell firing timing/synchronization",
    "Detection of static and slowly varying magnetic fields",
    "Reactive oxygen species (ROS)",
    "Calcium",
    "pH",
    "Fibrosarcoma cell growth rates",
    "Membrane potentials",
    "Pacemaker/clock cell firing rate",
    "Animal magnetoreception/navigation (proposed application)"
  ],
  "main_findings": "The authors propose a mechanism by which biological systems could detect static and slowly varying magnetic fields via magnetic-field-induced modifications in the timing of firing of adjacent nerve cells, mediated by local magnetic fields generated by currents during firing. They note prior findings that changes in static magnetic fields modify ROS, calcium, pH, fibrosarcoma cell growth rates, and membrane potentials, which are linked to changes in membrane potentials that can inhibit or accelerate firing of pacemaker/clock cells.",
  "effect_direction": "unclear",
  "limitations": [
    "Mechanistic proposal rather than a reported experimental study in the abstract",
    "No quantitative exposure metrics (field strength, frequency) provided in the abstract",
    "No described study population, methods, or sample size in the abstract"
  ],
  "evidence_strength": "insufficient",
  "confidence": 0.74,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "static magnetic fields",
    "slowly varying magnetic fields",
    "nerve cells",
    "synchronization",
    "firing timing",
    "membrane potential",
    "pacemaker cells",
    "clock cells",
    "reactive oxygen species",
    "calcium",
    "magnetoreception"
  ],
  "suggested_hubs": []
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.

NNEMF synthesis

Synthesis pending.

Original record: rfsafe.org paper 1584

Possible Mechanism for Synchronized Detection of Weak Magnetic Fields by Nerve · Non-native EMF