Share

Effect of extremely low frequency electromagnetic fields on bacterial membrane.

Sule Oncul, Esra M Cuce, Burak Aksu, Ayse Inhan Garip

PAPERpubmedInternational journal of radiation biology2016In vitro studyEffect: mixedEvidence: Low

Abstract

PURPOSE: The effect of extremely low frequency electromagnetic fields (ELF-EMF) on bacteria has attracted attention due to its potential for beneficial uses. This research aimed to determine the effect of ELF-EMF on bacterial membrane namely the membrane potential, surface potential, hydrophobicity, respiratory activity and growth. MATERIALS AND METHODS: Gram-positive Staphylococcus aureus and Gram-negative Escherichia coli were subjected to ELF-EMF, 50 Hz, 1 mT for 2 h. Membrane potential was determined by fluorescence spectroscopy with or without EDTA (Ethylenediaminetetraacetic acid) with DisC3(5) (3,3-dipropylthiacarbocyanine iodide), zeta potential measurements were performed by electrophoretic mobility, hydrophobicity of the membrane was measured with MATH (Microbial Adhesion to Hydrocarbons) test, respiratory activity was determined with CTC (5-Cyano-2,3-ditolyl tetrazolium chloride), colony forming unit (CFU) and DAPI (4',6-diamidino-2-phenylindole, dihydrochloride) was used for growth determinations. RESULTS: ELF-EMF caused changes in physicochemical properties of both Gram-positive and Gram-negative bacteria. Hyperpolarization was seen in S. aureus and EDTA-treated E. coli. Surface potential showed a positive shift in S. aureus contrariwise to the negative shift seen in EDTA-untreated E. coli. Respiratory activity increased in both bacteria. A slight decrease in growth was observed. CONCLUSION: These results show that ELF-EMF affects the crucial physicochemical processes in both Gram-positive and Gram-negative bacteria which need further research.

AI evidence extraction

At a glance
Study type
In vitro study
Effect direction
mixed
Population
—
Sample size
—
Exposure
ELF · 0.05 MHz · 2 h
Evidence strength
Low
Confidence: 78% · Peer-reviewed: yes

Main findings

Exposure to 50 Hz, 1 mT ELF-EMF for 2 h was associated with changes in physicochemical properties in both Staphylococcus aureus and Escherichia coli. Hyperpolarization was reported in S. aureus and in EDTA-treated E. coli; surface potential shifted positively in S. aureus and negatively in EDTA-untreated E. coli. Respiratory activity increased in both bacteria, and a slight decrease in growth was observed.

Outcomes measured

  • Bacterial membrane potential
  • Bacterial surface (zeta) potential
  • Bacterial membrane hydrophobicity
  • Bacterial respiratory activity
  • Bacterial growth (CFU
  • DAPI)

Limitations

  • Sample size not reported in abstract
  • In vitro bacterial model
  • generalizability to in vivo/clinical settings not addressed
  • Exposure conditions limited to a single frequency (50 Hz)
  • field strength (1 mT)
  • and duration (2 h)
View raw extracted JSON
{
  "study_type": "in_vitro",
  "exposure": {
    "band": "ELF",
    "source": null,
    "frequency_mhz": 0.05,
    "sar_wkg": null,
    "duration": "2 h"
  },
  "population": null,
  "sample_size": null,
  "outcomes": [
    "Bacterial membrane potential",
    "Bacterial surface (zeta) potential",
    "Bacterial membrane hydrophobicity",
    "Bacterial respiratory activity",
    "Bacterial growth (CFU, DAPI)"
  ],
  "main_findings": "Exposure to 50 Hz, 1 mT ELF-EMF for 2 h was associated with changes in physicochemical properties in both Staphylococcus aureus and Escherichia coli. Hyperpolarization was reported in S. aureus and in EDTA-treated E. coli; surface potential shifted positively in S. aureus and negatively in EDTA-untreated E. coli. Respiratory activity increased in both bacteria, and a slight decrease in growth was observed.",
  "effect_direction": "mixed",
  "limitations": [
    "Sample size not reported in abstract",
    "In vitro bacterial model; generalizability to in vivo/clinical settings not addressed",
    "Exposure conditions limited to a single frequency (50 Hz), field strength (1 mT), and duration (2 h)"
  ],
  "evidence_strength": "low",
  "confidence": 0.78,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "extremely low frequency",
    "ELF-EMF",
    "50 Hz",
    "1 mT",
    "Staphylococcus aureus",
    "Escherichia coli",
    "membrane potential",
    "zeta potential",
    "hydrophobicity",
    "respiratory activity",
    "growth",
    "EDTA"
  ],
  "suggested_hubs": []
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.

NNEMF synthesis

Synthesis pending.

Original record: rfsafe.org paper 4733

Effect of extremely low frequency electromagnetic fields on bacterial membrane. · Non-native EMF