Share

The effects of different intensities, frequencies and exposure times of extremely low-frequency electromagnetic fields on the growth of Staphylococcus aureus and Escherichia coli O157:H7.

Ece Bayır, Eyüp Bilgi, Aylin Şendemir-Ürkmez, E Esin Hameş-Kocabaş

PAPERpubmedElectromagnetic biology and medicine2015In vitro studyEffect: harmEvidence: Low

Abstract

The impact of different types of extremely low-frequency electromagnetic fields (ELF-EMF) on the growth of Staphylococcus aureus and Escherichia coli O157:H7 was investigated. The cultures of bacteria in broth media were exposed to sinusoidal homogenous ELF-EMF with 2 and 4 mT magnetic intensities. Each intensity for each bacteria was combined with three different frequencies (20, 40 and 50 Hz), and four different exposure times (1, 2, 4 and 6 h). A cell suspension of each experiment was diluted for the appropriate range and inoculated to Mueller-Hinton Agar (MHA) plates after exposure to ELF-EMF. The number of colony forming units (CFU) of both strains was obtained after incubation at 37 °C for 24 h. Data were statistically evaluated by one-way analysis of variance (ANOVA), statistical significance was described at p < 0.05 and data were compared with their non-exposed controls. Magnetic intensity, frequency and exposure time of ELF-EMFs changed the characteristic responses for both microorganisms. Samples exposed to ELF-EMF showed a statistically significant decrease compared to their controls in colony forming capability, especially at long exposure times. An exposure to 4 mT-20 Hz ELF-EMF of 6 h produced maximum inhibition of CFU compared to their controls for both microorganisms (95.2% for S. aureus and 85% for E. coli).

AI evidence extraction

At a glance
Study type
In vitro study
Effect direction
harm
Population
Staphylococcus aureus and Escherichia coli O157:H7 cultures in broth media
Sample size
—
Exposure
ELF · 1, 2, 4, and 6 h
Evidence strength
Low
Confidence: 78% · Peer-reviewed: yes

Main findings

Bacterial cultures exposed to sinusoidal homogeneous ELF-EMF at 2 or 4 mT across 20, 40, and 50 Hz showed statistically significant decreases in CFU compared with non-exposed controls, particularly at longer exposure times. The maximum inhibition was reported at 4 mT, 20 Hz for 6 h (95.2% for S. aureus; 85% for E. coli).

Outcomes measured

  • Bacterial growth (colony forming units
  • CFU)
  • Colony forming capability/inhibition vs non-exposed controls

Limitations

  • Sample size not reported in abstract
  • Only two bacterial strains tested
  • In vitro broth/agar conditions may not generalize beyond the experimental setting
  • Exposure characterization limited to magnetic flux density
  • frequency
  • and time (other parameters not described)
View raw extracted JSON
{
  "study_type": "in_vitro",
  "exposure": {
    "band": "ELF",
    "source": null,
    "frequency_mhz": null,
    "sar_wkg": null,
    "duration": "1, 2, 4, and 6 h"
  },
  "population": "Staphylococcus aureus and Escherichia coli O157:H7 cultures in broth media",
  "sample_size": null,
  "outcomes": [
    "Bacterial growth (colony forming units, CFU)",
    "Colony forming capability/inhibition vs non-exposed controls"
  ],
  "main_findings": "Bacterial cultures exposed to sinusoidal homogeneous ELF-EMF at 2 or 4 mT across 20, 40, and 50 Hz showed statistically significant decreases in CFU compared with non-exposed controls, particularly at longer exposure times. The maximum inhibition was reported at 4 mT, 20 Hz for 6 h (95.2% for S. aureus; 85% for E. coli).",
  "effect_direction": "harm",
  "limitations": [
    "Sample size not reported in abstract",
    "Only two bacterial strains tested",
    "In vitro broth/agar conditions may not generalize beyond the experimental setting",
    "Exposure characterization limited to magnetic flux density, frequency, and time (other parameters not described)"
  ],
  "evidence_strength": "low",
  "confidence": 0.78,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "ELF-EMF",
    "extremely low-frequency electromagnetic fields",
    "sinusoidal homogeneous field",
    "magnetic intensity",
    "2 mT",
    "4 mT",
    "20 Hz",
    "40 Hz",
    "50 Hz",
    "exposure time",
    "Staphylococcus aureus",
    "Escherichia coli O157:H7",
    "colony forming units",
    "CFU",
    "Mueller-Hinton Agar"
  ],
  "suggested_hubs": []
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.

NNEMF synthesis

Synthesis pending.

Original record: rfsafe.org paper 4558