Share

Genotoxic effects of intermediate frequency magnetic fields on blood leukocytes in vitro

PAPERmanual2019In vitro studyEffect: mixedEvidence: Low

Abstract

Genotoxic effects of intermediate frequency magnetic fields on blood leukocytes in vitro Brech A, Kubinyi G, Németh Z, Bakos J, Fiocchi S, Thuróczy G. Genotoxic effects of intermediate frequency magnetic fields on blood leukocytes in vitro. Mutat Res. 2019 Sep;845:403060. doi: 10.1016/j.mrgentox.2019.05.016. Abstract The widespread presence of electromagnetic sources in daily life has initiated several studies on the effects of radiofrequency and power frequency fields. Only few investigations on the genotoxic effects of exposure to intermediate frequency magnetic fields (IF-MF) have been done so far. Therefore, the aim of this study was to evaluate possible genotoxic effects of exposure to 123.90 kHz and 250.80 kHz IF-MF on canine and human blood. Blood was exposed to IF-MF at 630 A/m (0.79 mT) and 80 A/m (0.10 m T) with exposure durations of 1-5 h (hourly), 20 and 24 h. Cylindrically divided Petri dish system was developed for in vitro exposures where different induced current could be achieved in the samples at the same magnetic flux density level. For the assessment of genotoxicity the alkaline comet assay was applied. We detected a statistically significant increase in DNA damage only following 20 h exposure to IF-MF. ncbi.nlm.nih.gov

AI evidence extraction

At a glance
Study type
In vitro study
Effect direction
mixed
Population
Canine and human blood leukocytes (in vitro)
Sample size
—
Exposure
intermediate frequency · 1–5 h (hourly), 20 h, 24 h
Evidence strength
Low
Confidence: 74% · Peer-reviewed: yes

Main findings

Blood samples exposed to intermediate frequency magnetic fields at 123.90 kHz and 250.80 kHz showed a statistically significant increase in DNA damage only after 20 h exposure; other exposure durations were not reported as significant in the abstract.

Outcomes measured

  • DNA damage (alkaline comet assay)
  • Genotoxicity

Limitations

  • Sample size not reported in abstract
  • Only alkaline comet assay mentioned
  • no other genotoxicity endpoints described
  • In vitro blood exposure
  • relevance to in vivo health outcomes not addressed in abstract
  • Details on which frequency/intensity conditions drove the significant effect are not specified in the abstract
View raw extracted JSON
{
  "study_type": "in_vitro",
  "exposure": {
    "band": "intermediate frequency",
    "source": null,
    "frequency_mhz": null,
    "sar_wkg": null,
    "duration": "1–5 h (hourly), 20 h, 24 h"
  },
  "population": "Canine and human blood leukocytes (in vitro)",
  "sample_size": null,
  "outcomes": [
    "DNA damage (alkaline comet assay)",
    "Genotoxicity"
  ],
  "main_findings": "Blood samples exposed to intermediate frequency magnetic fields at 123.90 kHz and 250.80 kHz showed a statistically significant increase in DNA damage only after 20 h exposure; other exposure durations were not reported as significant in the abstract.",
  "effect_direction": "mixed",
  "limitations": [
    "Sample size not reported in abstract",
    "Only alkaline comet assay mentioned; no other genotoxicity endpoints described",
    "In vitro blood exposure; relevance to in vivo health outcomes not addressed in abstract",
    "Details on which frequency/intensity conditions drove the significant effect are not specified in the abstract"
  ],
  "evidence_strength": "low",
  "confidence": 0.74,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "intermediate frequency magnetic fields",
    "IF-MF",
    "123.90 kHz",
    "250.80 kHz",
    "blood leukocytes",
    "canine blood",
    "human blood",
    "in vitro",
    "alkaline comet assay",
    "DNA damage",
    "genotoxicity"
  ],
  "suggested_hubs": []
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.

NNEMF synthesis

Synthesis pending.

Original record: rfsafe.org paper 1689

Genotoxic effects of intermediate frequency magnetic fields on blood leukocytes in vitro · Non-native EMF