Share

No evidence for genotoxicity in mice due to exposure to intermediate-frequency magnetic fields used for wireless power-transfer systems

PAPERmanualMutation research. Genetic toxicology and environmental mutagenesis2021Animal studyEffect: no_effectEvidence: Low

Abstract

No evidence for genotoxicity in mice due to exposure to intermediate-frequency magnetic fields used for wireless power-transfer systems Shin Ohtani, Akira Ushiyama, Keiji Wada, Yukihisa Suzuki, Kazuyuki Ishii, Kenji Hattori. No evidence for genotoxicity in mice due to exposure to intermediate-frequency magnetic fields used for wireless power- transfer systems. Mutat Res. Mar-Apr 2021;863-864:503310. doi: 10.1016/j.mrgentox.2021.503310. Abstract Time varying magnetic fields (MFs) are used for the wireless power-transfer (WPT) technology. Especially, 85 kHz band MFs, which are included in the intermediate frequency (IF) band (300 Hz - 10 MHz), are commonly used WPT system for charging electric vehicles. Those applications of WPT technology have elicited public concern about health effects of IF-MF. However, existing data from health risk assessments are insufficient and additional data are needed. We assessed the genotoxic effects of IF-MF exposure on erythroid differentiation in mice. A high-intensity IF-MF mouse exposure system was constructed to induce an average whole-body electric field of 54.1 V/m. Blood samples were obtained from male mice before and after a 2-week IF-MF exposure (1 h/day, total: 10 h); X-irradiated mice were used as positive controls. We analyzed the blood samples with the micronucleus (MN) test and the Pig-a mutation assay. No significant differences were seen between IF-MF- exposed and sham-exposed mice in the frequencies of either MN or Pig-a mutations in mature erythrocytes and reticulocytes. IF-MF exposure did not induce genotoxicity in vivo under the study conditions (2.36× the basic restriction for occupational exposure, 22.9 V/m, in the International Commission on Non-Ionizing Radiation Protection (ICNIRP) guidelines). The absence of significant biological effects due to IF-MF exposure supports the practical application of this technology. Highlights • We examined the genotoxicity of IF-MF exposure >2× the ICNIRP guideline. • IF-MF had no genotoxic effects in an in vivo micronucleus test and Pig-a assay. • These observations are useful for assessing the safety of a WPT system. pubmed.ncbi.nlm.nih.gov

AI evidence extraction

At a glance
Study type
Animal study
Effect direction
no_effect
Population
Male mice
Sample size
—
Exposure
IF wireless power-transfer (WPT) system (electric vehicle charging) · 0.085 MHz · 2 weeks; 1 h/day (total 10 h)
Evidence strength
Low
Confidence: 78% · Peer-reviewed: yes

Main findings

Male mice exposed to 85 kHz intermediate-frequency magnetic fields (average whole-body electric field 54.1 V/m) for 2 weeks showed no significant differences versus sham-exposed mice in micronucleus frequencies or Pig-a mutation frequencies in mature erythrocytes and reticulocytes. Under the stated study conditions, IF-MF exposure did not induce in vivo genotoxicity.

Outcomes measured

  • Genotoxicity (micronucleus test in mature erythrocytes and reticulocytes)
  • Mutations (Pig-a mutation assay in mature erythrocytes and reticulocytes)
  • Erythroid differentiation (context of assessment)

Limitations

  • Sample size not reported in the provided abstract/metadata
  • Exposure regimen limited to 2 weeks and 10 total hours
  • Only male mice were studied
  • Endpoints limited to micronucleus test and Pig-a mutation assay in blood cells

Suggested hubs

  • who-icnirp (0.7)
    Study explicitly references ICNIRP basic restriction levels and compares exposure intensity to the guideline.
View raw extracted JSON
{
  "study_type": "animal",
  "exposure": {
    "band": "IF",
    "source": "wireless power-transfer (WPT) system (electric vehicle charging)",
    "frequency_mhz": 0.085,
    "sar_wkg": null,
    "duration": "2 weeks; 1 h/day (total 10 h)"
  },
  "population": "Male mice",
  "sample_size": null,
  "outcomes": [
    "Genotoxicity (micronucleus test in mature erythrocytes and reticulocytes)",
    "Mutations (Pig-a mutation assay in mature erythrocytes and reticulocytes)",
    "Erythroid differentiation (context of assessment)"
  ],
  "main_findings": "Male mice exposed to 85 kHz intermediate-frequency magnetic fields (average whole-body electric field 54.1 V/m) for 2 weeks showed no significant differences versus sham-exposed mice in micronucleus frequencies or Pig-a mutation frequencies in mature erythrocytes and reticulocytes. Under the stated study conditions, IF-MF exposure did not induce in vivo genotoxicity.",
  "effect_direction": "no_effect",
  "limitations": [
    "Sample size not reported in the provided abstract/metadata",
    "Exposure regimen limited to 2 weeks and 10 total hours",
    "Only male mice were studied",
    "Endpoints limited to micronucleus test and Pig-a mutation assay in blood cells"
  ],
  "evidence_strength": "low",
  "confidence": 0.78,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "intermediate-frequency magnetic fields",
    "IF-MF",
    "wireless power transfer",
    "WPT",
    "85 kHz",
    "electric vehicle charging",
    "genotoxicity",
    "micronucleus test",
    "Pig-a mutation assay",
    "ICNIRP guidelines",
    "in vivo",
    "mouse"
  ],
  "suggested_hubs": [
    {
      "slug": "who-icnirp",
      "weight": 0.72,
      "reason": "Study explicitly references ICNIRP basic restriction levels and compares exposure intensity to the guideline."
    }
  ]
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.

NNEMF synthesis

Synthesis pending.

Original record: rfsafe.org paper 1203

No evidence for genotoxicity in mice due to exposure to intermediate-frequency magnetic fields used for wireless power-transfer systems · Non-native EMF