Pre- and post-natal exposure of children to EMF generated by domestic induction cookers.
Abstract
Induction cookers are a type of cooking appliance that uses an intermediate-frequency magnetic field to heat the cooking vessel. The magnetic flux density produced by an induction cooker during operation was measured according to the EN 62233 standard, and the measured values were below the limits set in the standard. The measurements were used to validate a numerical model consisting of three vertically displaced coaxial current loops at 35 kHz. The numerical model was then used to compute the electric field (E) and induced current (J) in 26 and 30 weeks pregnant women and 6 and 11 year old children. Both E and J were found to be below the basic restrictions of the 2010 low-frequency and 1998 ICNRIP guidelines. The maximum computed E fields in the whole body were 0.11 and 0.66 V m(-1) in the 26 and 30 weeks pregnant women and 0.28 and 2.28 V m(-1) in the 6 and 11 year old children (ICNIRP basic restriction 4.25 V m(-1)). The maximum computed J fields in the whole body were 46 and 42 mA m(-2) in the 26 and 30 weeks pregnant women and 27 and 16 mA m(-2) in the 6 and 11 year old children (ICNIRP basic restriction 70 mA m(-2)).
AI evidence extraction
Main findings
Magnetic flux density measured during induction cooker operation (per EN 62233) was below the limits set in the standard. A numerical model at 35 kHz was used to compute internal electric field and induced current density in 26/30-week pregnant women and 6/11-year-old children; computed E and J were below ICNIRP basic restrictions (2010 low-frequency and 1998 guidelines).
Outcomes measured
- Magnetic flux density during induction cooker operation (EN 62233)
- Computed internal electric field (E)
- Computed induced current density (J)
- Compliance with EN 62233 limits and ICNIRP basic restrictions (2010 low-frequency
- 1998)
Suggested hubs
- who-icnirp (0.7)Assesses exposure relative to ICNIRP basic restrictions (1998 and 2010 low-frequency guidelines).
View raw extracted JSON
{
"study_type": "exposure_assessment",
"exposure": {
"band": "intermediate-frequency",
"source": "domestic induction cooker",
"frequency_mhz": 0.035,
"sar_wkg": null,
"duration": null
},
"population": "26 and 30 weeks pregnant women; 6 and 11 year old children",
"sample_size": null,
"outcomes": [
"Magnetic flux density during induction cooker operation (EN 62233)",
"Computed internal electric field (E)",
"Computed induced current density (J)",
"Compliance with EN 62233 limits and ICNIRP basic restrictions (2010 low-frequency; 1998)"
],
"main_findings": "Magnetic flux density measured during induction cooker operation (per EN 62233) was below the limits set in the standard. A numerical model at 35 kHz was used to compute internal electric field and induced current density in 26/30-week pregnant women and 6/11-year-old children; computed E and J were below ICNIRP basic restrictions (2010 low-frequency and 1998 guidelines).",
"effect_direction": "no_effect",
"limitations": [],
"evidence_strength": "low",
"confidence": 0.78,
"peer_reviewed_likely": "yes",
"keywords": [
"induction cooker",
"intermediate-frequency magnetic field",
"35 kHz",
"EN 62233",
"numerical model",
"pregnant women",
"children",
"electric field",
"induced current density",
"ICNIRP guidelines"
],
"suggested_hubs": [
{
"slug": "who-icnirp",
"weight": 0.78,
"reason": "Assesses exposure relative to ICNIRP basic restrictions (1998 and 2010 low-frequency guidelines)."
}
]
}AI can be wrong. Always verify against the paper.
Comments
Log in to comment.
No comments yet.
NNEMF synthesis
Synthesis pending.