Share

Bio-physical effects of RF EMR on blood parameters, spermatozoa, liver, kidney and heart of albino rats

PAPERmanual2018Animal studyEffect: harmEvidence: Low

Abstract

Bio-physical effects of RF EMR on blood parameters, spermatozoa, liver, kidney and heart of albino rats Adebayo EA, Adeeyo AO, Ogundiran MA, Olabisi O. Bio-physical effects of radiofrequency electromagnetic radiation (rf-emr) on blood parameters, spermatozoa, liver, kidney and heart of albino rats. Journal of King Saud University - Science. 15 Nov 2018. doi.org. Abstract Current study aimed at determining the consequence of Radiofrequency (≈1800 MHz) electromagnetic radiation (RF-EMR) on the histological, hematological and histochemical properties of selected tissues of rat and to assess morphological changes associated with such exposures. Three groups of thirty rats of which two groups of twenty rats were subjected to average radiation of ≈1.40 mW/cm2 at 24 m from the base of two different telecommunications network mast for 5 weeks. Histochemical, haematological and histological analyses of the rats were afterward carried out on selected tissues of the experimental animals using standard procedures. Impacts of radiation were noted in the exposed groups of rats. There was rise in white blood cells with variations in other blood parameters; the sperm motility and sperm count of the exposed rats is lower than the control; the liver of the exposed rats shows pronounced dilated sinusoids, distorted architecture, hyperchromatic nuclei, congested central vein, with change of hepatocytes structure; the heart shows gross distortion of cardiac muscular architecture with distorted irregular cardiac muscle fibres and wider interfibres spaces; kidney showing hyperchromatic nuclei, gradual loss and degeneration of flattened squamous epithelial cells lining and testis shows grossly distorted seminiferous tubules and epididymis with loss of cellular structure and an area of inflammatory changes with complete absence of spermatozoa, which may lead to low fertility. This study shows that radiofrequency electromagnetic radiation may induce morphological changes in various tissues of living systems in rat. Conclusion From the data presented in this study, it can be observed that impact of RF-EMR from telecommunication base stations are reasonably manifested on internal organs in a similar manner observed in ionizing radiation studies. Some of the organs examined showed histological, hematological and histochemical changes which are different from normal. The study established that the reproductive organs of male rats were seriously impaired, which may have similar effect on higher mammal. It is recommended that further research to study the long term effect of RF-EMR from telecommunication on living systems in Nigeria be intensified. : sciencedirect.com

AI evidence extraction

At a glance
Study type
Animal study
Effect direction
harm
Population
Albino rats
Sample size
30
Exposure
RF base station · 1800 MHz · 5 weeks
Evidence strength
Low
Confidence: 74% · Peer-reviewed: yes

Main findings

Rats exposed to RF-EMR (~1800 MHz; ~1.40 mW/cm2 at 24 m from telecommunications masts for 5 weeks) showed changes versus controls, including increased white blood cells with variations in other blood parameters, reduced sperm motility and sperm count, and multiple histological alterations in liver, heart, kidney, and male reproductive tissues (including reported absence of spermatozoa in epididymis). The authors conclude RF-EMR may induce morphological changes in various rat tissues.

Outcomes measured

  • Hematological parameters (e.g.
  • white blood cells and other blood parameters)
  • Sperm motility
  • Sperm count
  • Histology/histochemistry of liver
  • Histology of heart
  • Histology of kidney
  • Histology of testis/epididymis

Limitations

  • Exposure described as occurring at 24 m from base stations
  • details on exposure characterization beyond average power density are limited in the abstract (e.g.
  • SAR not reported).
  • Group allocation and exact numbers per group are unclear/inconsistently described in the abstract ("three groups of thirty rats"
  • "two groups of twenty rats").
  • No quantitative results
  • statistical methods
  • or variance measures are provided in the abstract.

Suggested hubs

  • occupational-exposure (0.7)
    Exposure source is telecommunications base stations; could relate to environmental/near-field exposure contexts, though not explicitly occupational.
View raw extracted JSON
{
  "study_type": "animal",
  "exposure": {
    "band": "RF",
    "source": "base station",
    "frequency_mhz": 1800,
    "sar_wkg": null,
    "duration": "5 weeks"
  },
  "population": "Albino rats",
  "sample_size": 30,
  "outcomes": [
    "Hematological parameters (e.g., white blood cells and other blood parameters)",
    "Sperm motility",
    "Sperm count",
    "Histology/histochemistry of liver",
    "Histology of heart",
    "Histology of kidney",
    "Histology of testis/epididymis"
  ],
  "main_findings": "Rats exposed to RF-EMR (~1800 MHz; ~1.40 mW/cm2 at 24 m from telecommunications masts for 5 weeks) showed changes versus controls, including increased white blood cells with variations in other blood parameters, reduced sperm motility and sperm count, and multiple histological alterations in liver, heart, kidney, and male reproductive tissues (including reported absence of spermatozoa in epididymis). The authors conclude RF-EMR may induce morphological changes in various rat tissues.",
  "effect_direction": "harm",
  "limitations": [
    "Exposure described as occurring at 24 m from base stations; details on exposure characterization beyond average power density are limited in the abstract (e.g., SAR not reported).",
    "Group allocation and exact numbers per group are unclear/inconsistently described in the abstract (\"three groups of thirty rats\"; \"two groups of twenty rats\").",
    "No quantitative results, statistical methods, or variance measures are provided in the abstract."
  ],
  "evidence_strength": "low",
  "confidence": 0.74,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "radiofrequency electromagnetic radiation",
    "RF-EMR",
    "1800 MHz",
    "telecommunications network mast",
    "base station",
    "power density",
    "rats",
    "hematology",
    "sperm motility",
    "sperm count",
    "liver histology",
    "kidney histology",
    "heart histology",
    "testis",
    "epididymis"
  ],
  "suggested_hubs": [
    {
      "slug": "occupational-exposure",
      "weight": 0.2,
      "reason": "Exposure source is telecommunications base stations; could relate to environmental/near-field exposure contexts, though not explicitly occupational."
    }
  ]
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.

NNEMF synthesis

Synthesis pending.

Original record: rfsafe.org paper 1969

Bio-physical effects of RF EMR on blood parameters, spermatozoa, liver, kidney and heart of albino rats · Non-native EMF