EMF biological effects
Share

Circulating antibody response of mice exposed to 9-GHz pulsed microwave radiation.

C G Liddle, J P Putnam, O H Lewter, M West, G Morrow

PAPERpubmedBioelectromagnetics1986Animal studyEffect: no_effectEvidence: Low

Abstract

Female CD-1 mice immunized against the bacterium Streptococcus pneumoniae type III were exposed to 9-GHz pulsed microwaves (pulse repetition rate 970-1,000, pulse width 1.0 microseconds, peak power 1 W/cm2) at an average incident power density of 1 mW/cm2 (calculated SAR congruent to 0.47 W/kg) for 2 h per day for 5 days. Circulating antibody titers for the microwave-exposed animals were not significantly different from those of the sham-irradiated animals, and there were no differences in any of the hematological parameters analyzed, indicating that 9-GHz pulsed microwaves at 1 mW/cm2 do not alter the immune response of mice immunized against S pneumoniae.

AI evidence extraction

At a glance
Study type
Animal study
Effect direction
no_effect
Population
Female CD-1 mice immunized against Streptococcus pneumoniae type III
Sample size
—
Exposure
microwave · 9000 MHz · 0.47 W/kg · 2 h/day for 5 days
Evidence strength
Low
Confidence: 78% · Peer-reviewed: yes

Main findings

Circulating antibody titers in microwave-exposed mice were not significantly different from sham-irradiated mice, and no differences were observed in analyzed hematological parameters under the stated exposure conditions.

Outcomes measured

  • Circulating antibody titers
  • Hematological parameters

Limitations

  • Sample size not reported in the provided abstract/metadata
  • Exposure described as incident power density
  • internal dose characterization beyond calculated SAR is not detailed
  • Short exposure duration (5 days) and limited follow-up information not described
View raw extracted JSON
{
  "study_type": "animal",
  "exposure": {
    "band": "microwave",
    "source": null,
    "frequency_mhz": 9000,
    "sar_wkg": 0.47,
    "duration": "2 h/day for 5 days"
  },
  "population": "Female CD-1 mice immunized against Streptococcus pneumoniae type III",
  "sample_size": null,
  "outcomes": [
    "Circulating antibody titers",
    "Hematological parameters"
  ],
  "main_findings": "Circulating antibody titers in microwave-exposed mice were not significantly different from sham-irradiated mice, and no differences were observed in analyzed hematological parameters under the stated exposure conditions.",
  "effect_direction": "no_effect",
  "limitations": [
    "Sample size not reported in the provided abstract/metadata",
    "Exposure described as incident power density; internal dose characterization beyond calculated SAR is not detailed",
    "Short exposure duration (5 days) and limited follow-up information not described"
  ],
  "evidence_strength": "low",
  "confidence": 0.78,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "mouse",
    "CD-1",
    "microwave",
    "9 GHz",
    "pulsed",
    "SAR",
    "immune response",
    "antibody titer",
    "Streptococcus pneumoniae",
    "hematology"
  ],
  "suggested_hubs": []
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.

NNEMF synthesis

Synthesis pending.

Original record: rfsafe.org paper 6205

Circulating antibody response of mice exposed to 9-GHz pulsed microwave radiation. · Non-native EMF