RF exposure assessment of baby surveillance devices in the frequency range 400 MHz-2.45
Abstract
RF exposure assessment of baby surveillance devices in the frequency range 400 MHz-2.45 GHz Vermeeren G, Joseph W, Martens L. Radiofrequency exposure assessment of baby surveillance devices in the frequency range 400 MHz-2.45 GHz. Bioelectromagnetics. 2018 Apr;39(3):244-248. doi: 10.1002/bem.22113. No abstract Excerpts We investigated the exposure, in terms of both the peak spatial‐averaged specific absorption rate (SAR) in 10 g of tissue and the time-averaged root-mean-squared (RMS) electric (E) field, induced by baby monitors operating in a frequency range between 400 MHz and 2.45 GHz. We selected nine commercially available baby monitors ... Considering all investigated devices, the peak spatial SAR in 10 g ranged from 0.09 to 0.37 W/kg, which is 22.3- 5.4 times below the ICNIRP basic restriction. In summary, we measured the induced time-averaged root-mean-square electric field strength and the peak spatial-averaged specific absorption rate from the baby unit of nine commercially available devices and compared both with the ICNIRP guidelines. The communication technologies implemented in the baby monitors were: PMR446, continuous transmission at 864 MHz, DECT, and communication in the ISM band at 2450 MHz. The electric field was measured at a distance of 50 cm from the baby unit of the baby monitor. We measured the SAR in a flat phantom filled with head tissue simulating liquid and the baby unit touching the flat phantom. The maximum time-averaged root-mean-square electric field value closest to the ICNIRP reference level over all investigated devices was 1.51 V/m (for modern‐electronics DBS 3), which is 19.4 times below the ICNIRP reference level at 466 MHz. The peak spatial‐averaged SAR in 10 g of tissue was 0.37 W/kg in head simulating tissue (for Alecto-DBX-82), which is 5.4 times below the basic restriction of 2 W/kg as specified by ICNIRP. ncbi.nlm.nih.gov Note: The ICNIRP guidelines were designed to protect users only from short-term thermal effects.
AI evidence extraction
Main findings
Nine commercially available baby monitors (400 MHz–2.45 GHz; PMR446, 864 MHz continuous transmission, DECT, and 2450 MHz ISM) were assessed. Peak spatial-averaged SAR in 10 g ranged from 0.09 to 0.37 W/kg, reported as 22.3–5.4 times below the ICNIRP basic restriction; the maximum measured time-averaged RMS E-field at 50 cm was 1.51 V/m, reported as 19.4 times below the ICNIRP reference level at 466 MHz.
Outcomes measured
- Peak spatial-averaged SAR in 10 g tissue (W/kg)
- Time-averaged RMS electric field strength (V/m)
- Comparison with ICNIRP basic restrictions/reference levels
Limitations
- No abstract provided
- information is from excerpts only
- E-field measurements were taken at a single stated distance (50 cm) from the baby unit
- SAR measurements used a flat phantom with head-tissue simulating liquid and the baby unit touching the phantom
- Only nine commercially available devices were selected
- selection criteria not described in provided text
Suggested hubs
- who-icnirp (0.7)Study explicitly compares measured SAR and E-field values with ICNIRP basic restrictions/reference levels.
View raw extracted JSON
{
"study_type": "exposure_assessment",
"exposure": {
"band": "RF",
"source": "baby monitor",
"frequency_mhz": null,
"sar_wkg": 0.37,
"duration": null
},
"population": null,
"sample_size": 9,
"outcomes": [
"Peak spatial-averaged SAR in 10 g tissue (W/kg)",
"Time-averaged RMS electric field strength (V/m)",
"Comparison with ICNIRP basic restrictions/reference levels"
],
"main_findings": "Nine commercially available baby monitors (400 MHz–2.45 GHz; PMR446, 864 MHz continuous transmission, DECT, and 2450 MHz ISM) were assessed. Peak spatial-averaged SAR in 10 g ranged from 0.09 to 0.37 W/kg, reported as 22.3–5.4 times below the ICNIRP basic restriction; the maximum measured time-averaged RMS E-field at 50 cm was 1.51 V/m, reported as 19.4 times below the ICNIRP reference level at 466 MHz.",
"effect_direction": "no_effect",
"limitations": [
"No abstract provided; information is from excerpts only",
"E-field measurements were taken at a single stated distance (50 cm) from the baby unit",
"SAR measurements used a flat phantom with head-tissue simulating liquid and the baby unit touching the phantom",
"Only nine commercially available devices were selected; selection criteria not described in provided text"
],
"evidence_strength": "low",
"confidence": 0.74,
"peer_reviewed_likely": "yes",
"keywords": [
"baby monitor",
"baby surveillance devices",
"radiofrequency",
"RF exposure",
"SAR",
"10 g SAR",
"RMS electric field",
"PMR446",
"DECT",
"ISM 2450 MHz",
"ICNIRP"
],
"suggested_hubs": [
{
"slug": "who-icnirp",
"weight": 0.78,
"reason": "Study explicitly compares measured SAR and E-field values with ICNIRP basic restrictions/reference levels."
}
]
}AI can be wrong. Always verify against the paper.