Abstract
Does radiofrequency radiation impact sleep? A double-blind, randomised, placebo-controlled, crossover pilot study Bijlsma N, Conduit R, Kennedy G, Cohen M. Does radiofrequency radiation impact sleep? A double-blind, randomised, placebo-controlled, crossover pilot study. Front Public Health. 2024 Oct 29;12:1481537. doi: 10.3389/fpubh.2024.1481537. Abstract The most common source of Radiofrequency Electromagnetic Field (RF-EMF) exposures during sleep includes digital devices, yet there are no studies investigating the impact of multi-night exposure to electromagnetic fields emitted from a baby monitor on sleep under real-world conditions in healthy adults. Given the rise in the number of people reporting to be sensitive to man-made electromagnetic fields, the ubiquitous use of Wi-Fi enabled digital devices and the lack of real-world data, we investigated the effect of 2.45 GHz radiofrequency exposure during sleep on subjective sleep quality, and objective sleep measures, heart rate variability and actigraphy in healthy adults. This pilot study was a 4-week randomised, double-blind, crossover trial of 12 healthy adults. After a one-week run-in period, participants were randomised to exposure from either an active or inactive (sham) baby monitor for 7 nights and then crossed over to the alternate intervention after a one-week washout period. Subjective and objective assessments of sleep included the Pittsburgh Insomnia Rating Scale (PIRS-20), electroencephalography (EEG), actigraphy and heart rate variability (HRV) derived from electrocardiogram. Sleep quality was reduced significantly (p < 0.05) and clinically meaningful during RF- EMF exposure compared to sham-exposure as indicated by the PIRS-20 scores. Furthermore, at higher frequencies (gamma, beta and theta bands), EEG power density significantly increased during the Non- Rapid Eye Movement sleep (p < 0.05). No statistically significant differences in HRV or actigraphy were detected. Our findings suggest that exposure to a 2.45 GHz radiofrequency device (baby monitor) may impact sleep in some people under real-world conditions; however, further large-scale real-world investigations with specified dosimetry are required to confirm these findings. : frontiersin.org
AI evidence extraction
Main findings
In this 12-participant double-blind randomized crossover pilot trial, subjective sleep quality (PIRS-20) was significantly and clinically meaningfully worse during 2.45 GHz RF-EMF exposure from a baby monitor compared with sham. EEG power density during NREM sleep significantly increased at higher frequencies (gamma, beta, and theta bands) during exposure. No statistically significant differences were detected for HRV or actigraphy.
Outcomes measured
- Subjective sleep quality (PIRS-20)
- EEG power density during sleep (including NREM
- gamma
- beta
- theta bands)
- Actigraphy sleep measures
- Heart rate variability (HRV) from ECG
Limitations
- Pilot study with small sample size (12 participants)
- Dosimetry not specified
- authors call for investigations with specified dosimetry
- Real-world exposure context may introduce uncontrolled variables
Suggested hubs
- wifi (0.7)Exposure was 2.45 GHz RF-EMF from a Wi-Fi-enabled baby monitor during sleep.
View raw extracted JSON
{
"publication_year": 2024,
"study_type": "randomized_trial",
"exposure": {
"band": "RF",
"source": "baby monitor",
"frequency_mhz": 2450,
"sar_wkg": null,
"duration": "7 nights active exposure and 7 nights sham exposure (crossover) with 1-week washout; 4-week study including 1-week run-in"
},
"population": "Healthy adults",
"sample_size": 12,
"outcomes": [
"Subjective sleep quality (PIRS-20)",
"EEG power density during sleep (including NREM; gamma, beta, theta bands)",
"Actigraphy sleep measures",
"Heart rate variability (HRV) from ECG"
],
"main_findings": "In this 12-participant double-blind randomized crossover pilot trial, subjective sleep quality (PIRS-20) was significantly and clinically meaningfully worse during 2.45 GHz RF-EMF exposure from a baby monitor compared with sham. EEG power density during NREM sleep significantly increased at higher frequencies (gamma, beta, and theta bands) during exposure. No statistically significant differences were detected for HRV or actigraphy.",
"effect_direction": "mixed",
"limitations": [
"Pilot study with small sample size (12 participants)",
"Dosimetry not specified; authors call for investigations with specified dosimetry",
"Real-world exposure context may introduce uncontrolled variables"
],
"evidence_strength": "low",
"confidence": 0.78,
"peer_reviewed_likely": "yes",
"stance": "concern",
"stance_confidence": 0.66,
"summary": "This double-blind randomized placebo-controlled crossover pilot study tested 2.45 GHz RF-EMF exposure from a baby monitor during sleep in 12 healthy adults. Subjective sleep quality (PIRS-20) was significantly worse during RF-EMF exposure versus sham, and EEG power density increased in higher-frequency bands during NREM sleep. HRV and actigraphy outcomes did not differ significantly. The authors state that larger real-world studies with specified dosimetry are needed to confirm the findings.",
"key_points": [
"The study used a double-blind randomized crossover design comparing active versus sham baby monitor exposure during sleep.",
"Exposure frequency was 2.45 GHz (Wi-Fi band) over 7 nights per condition with a one-week washout.",
"Subjective sleep quality (PIRS-20) was significantly reduced during RF-EMF exposure compared with sham.",
"EEG power density increased in gamma, beta, and theta bands during NREM sleep under exposure.",
"No statistically significant differences were found in HRV outcomes between exposure and sham.",
"No statistically significant differences were detected in actigraphy measures between exposure and sham.",
"The authors emphasize the need for larger studies with specified dosimetry to confirm results."
],
"categories": [
"Sleep",
"Wi-Fi / 2.4 GHz",
"Human Experimental Studies",
"Neurophysiology (EEG)"
],
"tags": [
"Randomized Crossover Trial",
"Double Blind",
"Placebo Controlled",
"Baby Monitor",
"2.45 GHz",
"RF-EMF Exposure",
"Subjective Sleep Quality",
"PIRS-20",
"EEG Power Density",
"NREM Sleep",
"Actigraphy",
"Heart Rate Variability"
],
"keywords": [
"radiofrequency",
"RF-EMF",
"2.45 GHz",
"baby monitor",
"sleep",
"PIRS-20",
"EEG",
"actigraphy",
"HRV",
"double-blind",
"randomised",
"crossover"
],
"suggested_hubs": [
{
"slug": "wifi",
"weight": 0.86,
"reason": "Exposure was 2.45 GHz RF-EMF from a Wi-Fi-enabled baby monitor during sleep."
}
],
"social": {
"tweet": "Pilot double-blind randomized crossover trial (n=12) tested 2.45 GHz RF-EMF from a baby monitor during sleep: PIRS-20 sleep quality worsened vs sham and NREM EEG power increased in higher-frequency bands; HRV and actigraphy showed no significant differences. Larger studies with dosimetry needed.",
"facebook": "A small double-blind randomized crossover pilot study in 12 healthy adults examined 2.45 GHz RF-EMF exposure from a baby monitor during sleep. Participants reported worse sleep quality (PIRS-20) during exposure vs sham, and EEG showed increased power in higher-frequency bands during NREM sleep, while HRV and actigraphy did not differ significantly. The authors call for larger real-world studies with specified dosimetry.",
"linkedin": "Frontiers in Public Health (2024) reports a double-blind randomized crossover pilot trial (n=12) assessing multi-night 2.45 GHz RF-EMF exposure from a baby monitor during sleep. Subjective sleep quality (PIRS-20) was significantly worse during exposure vs sham, and NREM EEG power increased in higher-frequency bands; HRV and actigraphy outcomes were not significantly different. Authors recommend larger real-world studies with specified dosimetry."
}
}AI can be wrong. Always verify against the paper.
Comments
Log in to comment.
No comments yet.
NNEMF synthesis
Bijlsma and colleagues ran a four-week double-blind, randomised, placebo-controlled crossover pilot in 12 healthy adults. After a one-week run-in, each person slept for seven nights next to either an active or an inactive (sham) baby monitor emitting 2.45 GHz radiofrequency, then crossed over after a one-week washout. They measured subjective sleep with the Pittsburgh Insomnia Rating Scale (PIRS-20), brain electrical activity with electroencephalography (EEG), movement with actigraphy, and heart-rate variability (HRV) from the electrocardiogram. Sleep quality on the PIRS-20 was reduced significantly (p < 0.05) and described as clinically meaningful during active exposure compared with sham. EEG power density rose significantly (p < 0.05) in the gamma, beta and theta bands during non-rapid eye movement (NREM) sleep. HRV and actigraphy showed no statistically significant difference. The authors conclude that a 2.45 GHz baby monitor may affect sleep in some people under real-world conditions, and they call for larger studies with specified dosimetry. This study did not report specific absorption rate (SAR, the energy absorbed per kilogram of tissue) or power density for the device used, so a numerical comparison with the 1.6 W/kg phone limit cannot be made from this record. A separate assessment of commercial baby monitors (mel:2132) found peak spatial SAR in 10 g of tissue between 0.09 and 0.37 W/kg, well below the 2 W/kg ICNIRP basic restriction and below the 1.6 W/kg FCC phone limit, which is the range in which a heating explanation is not expected. The present finding is therefore a non-thermal signal only if the device used here sits in that same low-dose range; the authors themselves say dosimetry was not specified. The result is not a claim that radiofrequency causes insomnia as a disease. It is a measured change in how sleep is experienced and in the electrical pattern of NREM sleep, in healthy adults, over seven nights, with no change in movement or heart-rate variability.