Share

The effect of electromagnetic field emitted by a mobile phone on the inhibitory control of saccades.

Tomoko Okano, Yasuo Terao, Toshiaki Furubayashi, Akihiro Yugeta, Ritsuko Hanajima, Yoshikazu Ugawa

PAPERpubmedClinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology2010randomized trialEffect: no_effectEvidence: Low

Abstract

OBJECTIVE: To investigate whether exposure to a pulsed high-frequency electromagnetic field (pulsed EMF) emitted by a mobile phone has short-term effects on the inhibitory control of saccades. METHODS: A double-blind, counterbalanced crossover study design was employed. We assessed the performance of 10 normal subjects on antisaccade (AS) and cued saccade (CUED) tasks as well as two types of overlap saccade (OL1, OL2) task before and after 30 min of exposure to EMF emitted by a mobile phone or sham exposure. RESULTS: After EMF or sham exposure, we observed a slight but significant shortening of latency in the CUED and OL2 tasks. AS amplitude decreased as well as the saccade velocities in the AS, CUED, and OL1 tasks after exposure. These changes occurred regardless of whether exposure was real or sham. The frequencies of pro-saccades in the AS task, saccades to cue in the CUED task, and prematurely initiated saccades in the overlap (OL2) task did not change significantly after real or sham EMF exposure. CONCLUSIONS: Thirty minutes of mobile phone exposure has no significant short-term effect on the inhibitory control of saccades. SIGNIFICANCE: The cortical processing responsible for saccade inhibition is not affected by exposure to EMF emitted by a mobile phone.

AI evidence extraction

At a glance
Study type
randomized trial
Effect direction
no_effect
Population
10 normal subjects
Sample size
10
Exposure
RF mobile phone · 30 min
Evidence strength
Low
Confidence: 78% · Peer-reviewed: yes

Main findings

In a double-blind, counterbalanced crossover study, several saccade metrics (e.g., CUED and OL2 latency shortening; AS amplitude and velocities in AS/CUED/OL1) changed after exposure, but these changes occurred regardless of real versus sham exposure. Measures more directly related to inhibitory control (e.g., pro-saccade frequency in AS, saccades to cue in CUED, premature saccades in OL2) did not change significantly after real or sham exposure. The authors conclude that 30 minutes of mobile phone EMF exposure has no significant short-term effect on inhibitory control of saccades.

Outcomes measured

  • Inhibitory control of saccades
  • Antisaccade (AS) task performance (e.g.
  • amplitude
  • velocity
  • pro-saccade frequency)
  • Cued saccade (CUED) task performance (e.g.
  • latency
  • saccades to cue)
  • Overlap saccade tasks (OL1
  • OL2) performance (e.g.
  • premature saccades)

Limitations

  • Small sample size (n=10)
  • Short-term exposure only (30 minutes)
  • Exposure parameters (e.g.
  • frequency
  • SAR) not reported in abstract
View raw extracted JSON
{
  "study_type": "randomized_trial",
  "exposure": {
    "band": "RF",
    "source": "mobile phone",
    "frequency_mhz": null,
    "sar_wkg": null,
    "duration": "30 min"
  },
  "population": "10 normal subjects",
  "sample_size": 10,
  "outcomes": [
    "Inhibitory control of saccades",
    "Antisaccade (AS) task performance (e.g., amplitude, velocity, pro-saccade frequency)",
    "Cued saccade (CUED) task performance (e.g., latency, velocity, saccades to cue)",
    "Overlap saccade tasks (OL1, OL2) performance (e.g., latency, velocity, premature saccades)"
  ],
  "main_findings": "In a double-blind, counterbalanced crossover study, several saccade metrics (e.g., CUED and OL2 latency shortening; AS amplitude and velocities in AS/CUED/OL1) changed after exposure, but these changes occurred regardless of real versus sham exposure. Measures more directly related to inhibitory control (e.g., pro-saccade frequency in AS, saccades to cue in CUED, premature saccades in OL2) did not change significantly after real or sham exposure. The authors conclude that 30 minutes of mobile phone EMF exposure has no significant short-term effect on inhibitory control of saccades.",
  "effect_direction": "no_effect",
  "limitations": [
    "Small sample size (n=10)",
    "Short-term exposure only (30 minutes)",
    "Exposure parameters (e.g., frequency, SAR) not reported in abstract"
  ],
  "evidence_strength": "low",
  "confidence": 0.78,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "mobile phone",
    "pulsed high-frequency electromagnetic field",
    "RF exposure",
    "double-blind",
    "crossover",
    "sham exposure",
    "saccades",
    "antisaccade",
    "inhibitory control",
    "latency",
    "velocity"
  ],
  "suggested_hubs": []
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.

NNEMF synthesis

Synthesis pending.

Original record: rfsafe.org paper 4397

The effect of electromagnetic field emitted by a mobile phone on the inhibitory control of saccades. · Non-native EMF