Share

Behavioral testing of mice exposed to intermediate frequency magnetic fields indicates mild memory impairment

PAPERmanual2017Animal studyEffect: mixedEvidence: Low

Abstract

Behavioral testing of mice exposed to intermediate frequency magnetic fields indicates mild memory impairment Kumari K, Koivisto H, Viluksela M, Paldanius KMA, Marttinen M, Hiltunen M, Naarala J, Tanila H, Juutilainen J. Behavioral testing of mice exposed to intermediate frequency magnetic fields indicates mild memory impairment. PLoS One. 2017 Dec 4;12(12):e0188880. Abstract Human exposure to intermediate frequency magnetic fields (MF) is increasing due to applications like electronic article surveillance systems and induction heating cooking hobs. However, limited data is available on their possible health effects. The present study assessed behavioral and histopathological consequences of exposing mice to 7.5 kHz MF at 12 or 120 μT for 5 weeks. No effects were observed on body weight, spontaneous activity, motor coordination, level of anxiety or aggression. In the Morris swim task, mice in the 120 μT group showed less steep learning curve than the other groups, but did not differ from controls in their search bias in the probe test. The passive avoidance task indicated a clear impairment of memory over 48 h in the 120 μT group. No effects on astroglial activation or neurogenesis were observed in the hippocampus. The mRNA expression of brain-derived neurotrophic factor did not change but expression of the proinflammatory cytokine tumor necrosis factor alpha mRNA was significantly increased in the 120 μT group. These findings suggest that 7.5 kHz MF exposure may lead to mild learning and memory impairment, possibly through an inflammatory reaction in the hippocampus. ncbi.nlm.nih.gov

AI evidence extraction

At a glance
Study type
Animal study
Effect direction
mixed
Population
Mice
Sample size
—
Exposure
intermediate frequency · 0.0075 MHz · 5 weeks
Evidence strength
Low
Confidence: 78% · Peer-reviewed: yes

Main findings

Mice exposed to 7.5 kHz magnetic fields at 120 μT for 5 weeks showed a less steep learning curve in the Morris swim task and impaired memory over 48 h in the passive avoidance task, while no effects were observed on body weight, activity, motor coordination, anxiety, or aggression. No hippocampal astroglial activation or neurogenesis effects were observed; BDNF mRNA did not change, but TNF-α mRNA was significantly increased in the 120 μT group.

Outcomes measured

  • Body weight
  • Spontaneous activity
  • Motor coordination
  • Anxiety
  • Aggression
  • Morris swim task (learning/probe test)
  • Passive avoidance task (memory over 48 h)
  • Astroglial activation in hippocampus
  • Neurogenesis in hippocampus
  • mRNA expression of brain-derived neurotrophic factor (BDNF)
  • mRNA expression of tumor necrosis factor alpha (TNF-α)

Suggested hubs

  • occupational-exposure (0.7)
    Abstract notes increasing human exposure due to electronic article surveillance systems and induction heating cooking hobs.
View raw extracted JSON
{
  "study_type": "animal",
  "exposure": {
    "band": "intermediate frequency",
    "source": null,
    "frequency_mhz": 0.0075,
    "sar_wkg": null,
    "duration": "5 weeks"
  },
  "population": "Mice",
  "sample_size": null,
  "outcomes": [
    "Body weight",
    "Spontaneous activity",
    "Motor coordination",
    "Anxiety",
    "Aggression",
    "Morris swim task (learning/probe test)",
    "Passive avoidance task (memory over 48 h)",
    "Astroglial activation in hippocampus",
    "Neurogenesis in hippocampus",
    "mRNA expression of brain-derived neurotrophic factor (BDNF)",
    "mRNA expression of tumor necrosis factor alpha (TNF-α)"
  ],
  "main_findings": "Mice exposed to 7.5 kHz magnetic fields at 120 μT for 5 weeks showed a less steep learning curve in the Morris swim task and impaired memory over 48 h in the passive avoidance task, while no effects were observed on body weight, activity, motor coordination, anxiety, or aggression. No hippocampal astroglial activation or neurogenesis effects were observed; BDNF mRNA did not change, but TNF-α mRNA was significantly increased in the 120 μT group.",
  "effect_direction": "mixed",
  "limitations": [],
  "evidence_strength": "low",
  "confidence": 0.78,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "intermediate frequency",
    "magnetic fields",
    "7.5 kHz",
    "12 μT",
    "120 μT",
    "mice",
    "behavior",
    "learning",
    "memory",
    "Morris swim task",
    "passive avoidance",
    "hippocampus",
    "TNF-alpha",
    "BDNF",
    "neurogenesis",
    "astroglial activation"
  ],
  "suggested_hubs": [
    {
      "slug": "occupational-exposure",
      "weight": 0.25,
      "reason": "Abstract notes increasing human exposure due to electronic article surveillance systems and induction heating cooking hobs."
    }
  ]
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.

NNEMF synthesis

Synthesis pending.

Original record: rfsafe.org paper 2209

Behavioral testing of mice exposed to intermediate frequency magnetic fields indicates mild memory impairment · Non-native EMF