Share

Modification of the repeated acquisition of response sequences in rats by low-level microwave exposure.

J Schrot, J R Thomas, R A Banvard

PAPERpubmedBioelectromagnetics1980Animal studyEffect: harmEvidence: Very low

Abstract

The acute effects of microwave exposure on a repeated acquisition baseline were investigated in three rats. Each session the animals acquired a different four-member response sequence. Each of the first three correct responses advanced the sequence to the next member, and the fourth correct response produced food reinforcement. Incorrect responses produced a three-second timeout. Baseline and control sessions were characterized by a decrease in errors within each session. The animals were acutely exposed to a 2.8 GHz pulsed-microwave field prior to test sessions, with average power densities ranging from 0.25 to to 10 mW/cm2. In comparison to control sessions, 1/2 hour of exposure to microwave radiation at power densities of 5 and 10 mW/cm2 increased errors and altered the pattern of within-session acquisition. Exposure to the 10 mW/cm2 power density decreased the rate of sequence completion in all animals. The results of exposures at 0.25, 0.5, and 1 mW/cm2 power densities were generally within the control range. The results are interpreted as indicating a disruption in the discriminative stimulus control of the repeated acquisition behavior.

AI evidence extraction

At a glance
Study type
Animal study
Effect direction
harm
Population
Three rats
Sample size
3
Exposure
microwave · 2800 MHz · 1/2 hour (acute exposure prior to test sessions)
Evidence strength
Very low
Confidence: 78% · Peer-reviewed: yes

Main findings

Rats acutely exposed to a 2.8 GHz pulsed-microwave field at average power densities of 5 and 10 mW/cm2 showed increased errors and altered within-session acquisition compared with control sessions. Exposure at 10 mW/cm2 decreased the rate of sequence completion in all animals, while results at 0.25, 0.5, and 1 mW/cm2 were generally within the control range.

Outcomes measured

  • Repeated acquisition of response sequences (errors)
  • Pattern of within-session acquisition
  • Rate of sequence completion

Limitations

  • Very small sample size (three rats)
  • Acute exposure only
  • no long-term effects assessed
  • Exposure metric reported as power density
  • SAR not reported
View raw extracted JSON
{
  "study_type": "animal",
  "exposure": {
    "band": "microwave",
    "source": null,
    "frequency_mhz": 2800,
    "sar_wkg": null,
    "duration": "1/2 hour (acute exposure prior to test sessions)"
  },
  "population": "Three rats",
  "sample_size": 3,
  "outcomes": [
    "Repeated acquisition of response sequences (errors)",
    "Pattern of within-session acquisition",
    "Rate of sequence completion"
  ],
  "main_findings": "Rats acutely exposed to a 2.8 GHz pulsed-microwave field at average power densities of 5 and 10 mW/cm2 showed increased errors and altered within-session acquisition compared with control sessions. Exposure at 10 mW/cm2 decreased the rate of sequence completion in all animals, while results at 0.25, 0.5, and 1 mW/cm2 were generally within the control range.",
  "effect_direction": "harm",
  "limitations": [
    "Very small sample size (three rats)",
    "Acute exposure only; no long-term effects assessed",
    "Exposure metric reported as power density; SAR not reported"
  ],
  "evidence_strength": "very_low",
  "confidence": 0.78,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "microwave",
    "pulsed microwave",
    "2.8 GHz",
    "2800 MHz",
    "power density",
    "mW/cm2",
    "rats",
    "behavior",
    "learning",
    "repeated acquisition",
    "response sequences"
  ],
  "suggested_hubs": []
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.

NNEMF synthesis

Synthesis pending.

Original record: rfsafe.org paper 6035

Modification of the repeated acquisition of response sequences in rats by low-level microwave exposure. · Non-native EMF